A Theoretical Comparative Study of CO2 Cascade Refrigeration Systems

被引:34
|
作者
Bellos, Evangelos [1 ]
Tzivanidis, Christos [1 ]
机构
[1] Natl Tech Univ Athens, Sch Mech Engn, Thermal Dept, Athens 15780, Greece
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 04期
关键词
CO2; refrigerant; cascade; total equivalent warming impact; refrigerant comparison; yearly COP; ADVANCED EXERGY ANALYSIS; SUPERMARKET REFRIGERATION; THERMODYNAMIC ANALYSIS; PERFORMANCE; ENERGY; COMPRESSION; EJECTOR; CYCLE; OPTIMIZATION; WORKING;
D O I
10.3390/app9040790
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The objective of this work is the comparison of the different cascade refrigeration systems with CO2 in the low-temperature circuit. A total of 18 different cascade refrigeration systems are examined including the CO2/CO2 cascade system. The analysis is performed for four different evaporator temperatures (-35, -25, -15 and -5 degrees C), while the condenser temperature is ranged from 10 up to 45 degrees C. The systems are compared energetically, as well as using the total equivalent warming impact (TEWI) for yearly operation at the weather conditions of Athens (Greece). The final results show that all the examined cascade systems are more efficient than the CO2/CO2 cascade system. The natural refrigerants (NH3, R290, R600, R600a and R1270) seem to be the most appropriate choices according to the energy and the TEWI criteria. Moreover, the refrigerant R152a is a promising choice for achieving high performance with a relatively low TEWI.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] A comparative study of CO2 refrigeration systems
    Bellos, Evangelos
    Tzivanidis, Christos
    [J]. ENERGY CONVERSION AND MANAGEMENT-X, 2019, 1
  • [2] A COMPARATIVE STUDY ON THE ENVIRONMENTAL IMPACT OF CO2 SUPERMARKET REFRIGERATION SYSTEMS
    Beshr, M.
    Aute, V.
    Sharma, V.
    Abdelaziz, O.
    Fricke, B.
    Radermacher, R.
    [J]. 11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 269 - 276
  • [3] REFRIGERATION CHAMBERS - CASCADE OR CO2
    MEDITZ, JA
    [J]. ENVIRONMENTAL QUARTERLY, 1968, 14 (01): : 36 - &
  • [4] Comparative analysis of various CO2 configurations in supermarket refrigeration systems
    Sharma, Vishaldeep
    Fricke, Brian
    Bansal, Pradeep
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 46 : 86 - 99
  • [5] Comparative thermodynamic performance analysis of a cascade refrigeration system with new refrigerants paired with CO2
    Adebayo, Victor
    Abid, Muhammad
    Adedeji, Michael
    Dagbasi, Mustafa
    Bamisile, Olusola
    [J]. APPLIED THERMAL ENGINEERING, 2021, 184
  • [6] Theoretical study on a novel CO2 Two-stage compression refrigeration system with parallel compression and solar absorption partial cascade refrigeration system
    Sun, Zhili
    Wang, Caiyun
    Liang, Youcai
    Sun, Huan
    Liu, Shengchun
    Dai, Baomin
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2020, 204 (204)
  • [7] Performance of CO2 mixtures used in cascade refrigeration system
    School of Environment Science and Engineering, Tianjin University, Tianjin 300072, China
    [J]. Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban), 2006, 12 (1422-1427):
  • [8] CASCADE SYSTEM COMBINED BY SOLAR EJECTOR REFRIGERATION CYCLE AND CO2 REFRIGERATION CYCLE
    Li, Minxia
    Gong, Xiufeng
    Dang, Chaobin
    Li, Hao
    [J]. 12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 705 - 712
  • [9] Thermoeconomic optimization and exergy analysis of CO2/NH3 cascade refrigeration systems
    Rezayan, Omid
    Behbahaninia, Ali
    [J]. ENERGY, 2011, 36 (02) : 888 - 895
  • [10] Comparative analysis of thermodynamic performance of CO2 cascade refrigeration system assisted with expander and mechanical subcooling
    Sun, Zhili
    Wang, Qifan
    Su, Dandan
    Liu, Shengchun
    Dai, Baomin
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (14) : 7891 - 7907