Automated Measurement of Intracranial Volume Using Three-Dimensional Photography

被引:8
|
作者
Tu, Liyun
Porras, Antonio R.
Enquobahrie, Andinet
Buck, Graham C.
Tsering, Deki
Horvath, Samantha
Keating, Robert
Oh, Albert K.
Rogers, Gary F.
George Linguraru, Marius
机构
[1] Childrens Natl Hosp, Sheikh Zayed Inst Pediat Surg Innovat, Div Neurosurg, Washington, DC USA
[2] Childrens Natl Hosp, Div Plast & Reconstruct Surg, Washington, DC USA
[3] Kitware Inc, Clifton Pk, NY USA
[4] George Washington Univ, Sch Med & Hlth Sci, Dept Radiol, Washington, DC 20052 USA
[5] George Washington Univ, Sch Med & Hlth Sci, Dept Pediat, Washington, DC 20052 USA
基金
美国国家卫生研究院;
关键词
COMPUTED-TOMOGRAPHY; SAGITTAL SYNOSTOSIS; PRETERM INFANTS; BRAIN VOLUME; HEAD GROWTH; CHILDREN; CRANIOSYNOSTOSIS; SHAPE; PHOTOGRAMMETRY; PRESSURE;
D O I
10.1097/PRS.0000000000007066
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Current methods to analyze three-dimensional photography do not quantify intracranial volume, an important metric of development. This study presents the first noninvasive, radiation-free, accurate, and reproducible method to quantify intracranial volume from three-dimensional photography. Methods: In this retrospective study, cranial bones and head skin were automatically segmented from computed tomographic images of 575 subjects without cranial abnormality (average age, 5 +/- 5 years; range, 0 to 16 years). The intracranial volume and the head volume were measured at the cranial vault region, and their relation was modeled by polynomial regression, also accounting for age and sex. Then, the regression model was used to estimate the intracranial volume of 30 independent pediatric patients from their head volume measured using three-dimensional photography. Evaluation was performed by comparing the estimated intracranial volume with the true intracranial volume of these patients computed from paired computed tomographic images; two growth models were used to compensate for the time gap between computed tomographic and three-dimensional photography. Results: The regression model estimated the intracranial volume of the normative population from the head volume calculated from computed tomographic images with an average error of 3.81 +/- 3.15 percent (p= 0.93) and a correlation (R-2) of 0.96. The authors obtained an average error of 4.07 +/- 3.01 percent (p= 0.57) in estimating the intracranial volume of the patients from three-dimensional photography using the regression model. Conclusion: Three-dimensional photography with image analysis provides measurement of intracranial volume with clinically acceptable accuracy, thus offering a noninvasive, precise, and reproducible method to evaluate normal and abnormal brain development in young children.
引用
收藏
页码:314E / 323E
页数:10
相关论文
共 50 条
  • [1] Discussion: Automated Measurement of Intracranial Volume Using Three-Dimensional Photography
    Taylor, Jesse A.
    Shakir, Sameer
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2020, 146 (03) : 324E - 325E
  • [2] Measurement of intracranial translucency using three-dimensional ultrasound and Volume IT™
    Lee, Mi-Young
    Won, Hye-Sung
    Jeong, Ba-Da
    Hyun, Min-Kyung
    Lee, Hee-Young
    Shim, Jae-Yoon
    Lee, Pil-Ryang
    Kim, Ahm
    [J]. PRENATAL DIAGNOSIS, 2012, 32 (05) : 472 - 475
  • [3] Three-dimensional volume measurement
    Schwartz, G
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1998, 11 (01) : 4 - 5
  • [4] Three-dimensional photography
    Jacobs, RA
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2001, 107 (01) : 276 - 277
  • [5] Measurement of three-dimensional displacement fields and shape using electronic speckle photography
    Synnergren, P
    [J]. OPTICAL ENGINEERING, 1997, 36 (08) : 2302 - 2310
  • [6] Measuring Cranial Vault Volume With Three-Dimensional Photography: A Method of Measurement Comparable to the Gold Standard
    McKay, Douglas R.
    Davidge, Kristen M.
    Williams, Susanne K.
    Ellis, Lloyd A.
    Chong, David K.
    Teixeira, Rodrigo P.
    Greensmith, Andrew L.
    Holmes, Anthony D.
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (05) : 1419 - 1422
  • [7] Three-dimensional television using integral photography
    Okano, F
    Arai, J
    Okui, M
    [J]. LEOS 2001: 14TH ANNUAL MEETING OF THE IEEE LASERS & ELECTRO-OPTICS SOCIETY, VOLS 1 AND 2, PROCEEDINGS, 2001, : 487 - 488
  • [8] Serial fetal lung volume measurement using three-dimensional ultrasound
    Bahmaie, A
    Hughes, SW
    Clark, T
    Milner, A
    Saunders, J
    Tilling, K
    Maxwell, DJ
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 16 (02) : 154 - 158
  • [9] Thalamic volume measurement in normal fetuses using three-dimensional sonography
    Sotiriadis, Alexandros
    Dimitrakopoulos, Ioannis
    Eleftheriades, Makarios
    Agorastos, Theodoros
    Makrydimas, George
    [J]. JOURNAL OF CLINICAL ULTRASOUND, 2012, 40 (04) : 207 - 213
  • [10] Three-dimensional displacement measurement by fringe projection and speckle photography
    Barrientos, B.
    Cerca, M.
    Garcia-Marquez, J.
    Hernandez-Bernal, C.
    [J]. RIAO/OPTILAS 2007, 2008, 992 : 828 - +