Single-Laboratory Validation of a Gas Chromatographic Method of Direct Determination of Volatile Compounds in Spirit Drinks: Need for an Improved Interlaboratory Study

被引:9
|
作者
Charapitsa, Siarhei V. [1 ]
Sytova, Svetlana N. [1 ]
Korban, Anton L. [1 ,2 ]
Sobolenko, Lidia N. [1 ,2 ]
机构
[1] Belarusian State Univ, Inst Nucl Problems, Bobruyskaya St 11, Minsk, BELARUS
[2] Belarusian State Univ, Nezavisimosti Ave 4, Minsk, BELARUS
关键词
D O I
10.5740/jaoacint.18-0258
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: The quality and safety control of an alcoholic drink is mainly the establishment of its chemical content, particularly the quantity of volatile compounds. Objective: A single-laboratory validation of a gas chromatographic method of direct determination of volatile compounds in spirit drinks was conducted. The discussed method applies ethanol, the major volatile component of an alcoholic beverage, as an internal standard. Possible algorithms of method validation based on interlaboratory study were proposed and described. Methods: Seven standard solutions of the following volatile compounds were prepared gravimetrically in 40% (v/v) water-ethanol solution: acetaldehyde, methyl acetate, ethyl acetate, methanol, 2-propanol, 1-propanol, isobutanol, 1-butanol, and isoamylol. Each sample was measured with the proposed method 30 times in repeatability conditions. Results: Flame ionization detector response was linearly correlated with assigned concentrations at a range of 2 to 5000 mg/L of absolute alcohol (AA) with coefficients of determination (R-2) more than 0.995 for all analyzed components. Repeatability (RSDr <= 4.5%; RSDr <= 2.0%), reproducibility (RSDr <= 5.0%; RSDr 5 2.0%), and trueness (relative bias <= 2.6%; relative bias 51.4%) were obtained for low (10-25 mg/L AA for methanol and 2-10 for other volatiles) and high (25-5000 mg/L AA for methanol and 10-5000 for other volatiles) ranges of concentrations, correspondingly. Conclusions: The method increases the reliability of measurements and eliminates manual procedures of internal standard addition into both calibration standard solutions and spirit drinks.
引用
收藏
页码:669 / 672
页数:4
相关论文
共 50 条
  • [1] Gas chromatographic determination of volatile congeners in spirit drinks: Interlaboratory study
    Kelly, J
    Chapman, S
    Brereton, P
    Bertrand, A
    Guillou, C
    Wittkowski, R
    [J]. JOURNAL OF AOAC INTERNATIONAL, 1999, 82 (06) : 1375 - 1388
  • [2] Gas chromatographic determination of volatile congeners in spirit drinks: Interlaboratory study
    Min. of Agric. Fisheries and Food, CSL Food Science Laboratory, Norwich Research Park, Colney, Norwich, NR4 7UQ, United Kingdom
    不详
    不详
    不详
    [J]. J AOAC Int, 6 (1375-1388):
  • [3] Direct Determination of Volatile Compounds in Spirit Drinks by Gas Chromatography
    Charapitsa, Siarhei V.
    Kavalenka, Anton N.
    Kulevich, Nikita V.
    Makoed, Nicolai M.
    Mazanik, Arkadzi L.
    Sytova, Svetlana N.
    Zayats, Natalia I.
    Kotov, Yurii N.
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2013, 61 (12) : 2950 - 2956
  • [4] Direct determination of volatile compounds in spirit drinks by gas chromatography
    [J]. Charapitsa, S.V. (svcharapitsa@tut.by), 1600, American Chemical Society (61):
  • [5] Multiresidue method for determination of algal toxins in shellfish: Single-laboratory validation and interlaboratory study
    McNabb, P
    Selwood, AI
    Holland, PT
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2005, 88 (03) : 761 - 772
  • [6] Single-Laboratory Validation of a Method for the Determination of Select Volatile Organic Compounds in Foods by Using Vacuum Distillation with Gas Chromatography/Mass Spectrometry
    Nyman, Patricia J.
    Limm, William
    Begley, Timothy H.
    Chirtel, Stuart J.
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (02) : 510 - 520
  • [7] Single-laboratory validation of a method for ergosterol determination in cereals
    Miyagawa, H.
    Umeda, M.
    Sato, T.
    Bandoh, S.
    Nakamura, S.
    Goto, T.
    [J]. FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2009, 26 (02): : 201 - 206
  • [8] Determination of Oxadixyl in Wines by Liquid Chromatography-Tandem Mass Spectrometry: Single-Laboratory and Interlaboratory Validation Study
    Mirzoian, Armen
    Ammann, Jeffrey R.
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (06) : 1701 - 1706
  • [9] Determination of Antimycin-A in Water by Liquid Chromatographic/Mass Spectrometry: Single-Laboratory Validation
    Bernardy, Jeffry A.
    Hubert, Terrance D.
    Ogorek, Jacob M.
    Schmidt, Larry J.
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2013, 96 (02) : 413 - 421
  • [10] Determination of Direct Available Phosphate in Fertilizers by a Discrete Analyzer: Single-Laboratory Validation
    Nimick, Ryan
    Mehlbrech, Laura
    Novotny, Lawrence
    Thiex, Nancy
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2012, 95 (05) : 1386 - 1391