LNG Technology: The Weathering in Above-Ground Storage Tanks

被引:46
|
作者
Pellegrini, Laura A. [1 ]
Moioli, Stefania [1 ]
Brignoli, Fabio [1 ]
Bellini, Camilla [2 ]
机构
[1] Politecn Milan, Dipartimento Chim Mat & Ingn Chim G Natta, I-20133 Milan, Italy
[2] Univ Commerciale Luigi Bocconi, I-20136 Milan, Italy
关键词
PREDICTION; DENSITIES; LIQUIDS;
D O I
10.1021/ie404128d
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Liquefied natural gas (LNG) is an energy source with worldwide steady growth: natural gas supply, as gas demand, is expected to grow in the near future. LNG is stored in tanks at pressure slightly higher than the atmospheric value and at its boiling point. Despite the high degree of insulation in the tank walls, it is impossible to avoid a net input heat transfer from the surroundings, so that vaporization is always present. It causes an increase in the pressure of the tank and a consequent boiloff in order to avoid overpressure. The change in composition and density of the liquid phase is called LNG aging or weathering. This phenomenon has been studied in order to obtain a model that can predict the variations that occur in the tank over time. Unlike other previously developed models, the proposed model does not require knowledge of the boiloff rate; instead, it calculates the rate directly from the heat flow to the tank. As a consequence, from a comparison with experimental data, it is proved that a more reliable representation of the phenomenon can be obtained.
引用
收藏
页码:3931 / 3937
页数:7
相关论文
共 50 条
  • [1] CP Criteria for above-ground storage tanks
    不详
    [J]. MATERIALS PERFORMANCE, 2007, 46 (04) : 32 - 34
  • [2] ABOVE-GROUND STORAGE TANKS FOR LIQUEFIED NATURAL GAS
    WISSMILL.IL
    [J]. MECHANICAL ENGINEERING, 1967, 89 (02) : 75 - &
  • [3] FRP linings in above-ground storage tanks: How strong are they?
    Hummel, Bob
    [J]. Water Engineering and Management, 2000, 147 (05):
  • [4] Seismic intensity measures for above-ground liquid storage tanks
    Bakalis, Konstantinos
    Kohrangi, Mohsen
    Vamvatsikos, Dimitrios
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2018, 47 (09): : 1844 - 1863
  • [5] The influence of maintenance on the life cycle of above-ground storage tanks
    Pearson, N. R.
    Mason, J. S. D.
    Priewald, R. H.
    [J]. INSIGHT, 2012, 54 (06) : 311 - 315
  • [6] Evaluating the Seismic Resilience of Above-Ground Liquid Storage Tanks †
    Brunesi, Emanuele
    Nascimbene, Roberto
    [J]. Buildings, 2024, 14 (10)
  • [7] FRP linings in above-ground storage tanks: How strong are they?
    Hummel, B
    [J]. WATER-ENGINEERING & MANAGEMENT, 2000, 147 (05): : 18 - +
  • [8] ACOUSTIC-EMISSION MONITORING OF ABOVE-GROUND STORAGE TANKS
    NICKOLAUS, CM
    [J]. MATERIALS EVALUATION, 1988, 46 (04) : 508 - 512
  • [10] The optimum temperature of Brine Heating System for above-ground LNG storage tank
    Oh, BT
    Hong, SH
    Yang, YM
    Kim, YK
    [J]. PROCEEDINGS OF THE FOURTEENTH (2004) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 4, 2004, : 402 - 406