Non-destructive Testing of Through Silicon Vias by High-resolution X-ray/CT Techniques

被引:0
|
作者
Jing, Xiangmeng [1 ]
Yu, Daquan [1 ]
Wan, Lixi [1 ]
机构
[1] Chinese Acad Sci, Inst Microelect, Beijing 10029, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Detecting through silicon via (TSV) associated defects non-destructively immediately after the fabrication process, or in failure analysis is of great interest and is a challenge. This paper reports on the inspections of 5 to 30 mu m diameter TSVs by the state-of-the-art, commercially available X-ray systems, exemplifying a generally preferred method for non-invasively identifying metallization defects in vias as well as in joining structures. The principle of X-ray imaging for TSV measurement is discussed and illustrated, and three dimensional TSV structures are reconstructed by computed tomography (CT). Methods to achieve high-resolution TSV X-ray imaging are discussed.
引用
收藏
页码:533 / 536
页数:4
相关论文
共 50 条
  • [1] Non-destructive testing of through silicon vias by using X-ray microscopy
    Jing, Xiangmeng
    Yu, Daquan
    Wang, Wei
    Yu, Guoqing
    Wan, Lixi
    2012 13TH INTERNATIONAL CONFERENCE ON ELECTRONIC PACKAGING TECHNOLOGY & HIGH DENSITY PACKAGING (ICEPT-HDP 2012), 2012, : 1255 - 1258
  • [2] High-resolution, Non-destructive X-ray Tomography
    Holler, Mirko
    Guizar-Sicairos, Manuel
    Tsai, Esther H. R.
    Odstrcil, Michal
    Dinapoli, Roberto
    Mueller, Elisabeth
    Diaz, Ana
    Bunk, Oliver
    Raab, Jorg
    Aeppli, Gabriel
    CHIMIA, 2018, 72 (05) : 339 - 339
  • [3] Non-destructive quantification of cereal roots in soil using high-resolution X-ray tomography
    Flavel, Richard J.
    Guppy, Christopher N.
    Tighe, Matthew
    Watt, Michelle
    McNeill, Ann
    Young, Iain M.
    JOURNAL OF EXPERIMENTAL BOTANY, 2012, 63 (07) : 2503 - 2511
  • [4] X-ray shearing interferometer for non-destructive testing
    Iwata, K
    Tadano, H
    Kikuta, H
    Hagino, H
    Nakano, T
    EXPERIMENTAL MECHANICS, VOLS 1 AND 2: ADVANCES IN DESIGN, TESTING AND ANALYSIS, 1998, : 741 - 745
  • [5] Non-destructive, high-resolution X-ray micro-CT of a Hairy Stalagmite: investigating the structural details of a biogenic speleothem
    du Preez, G.
    du Plessis, A.
    de Beer, D.
    Forti, P.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2018, 15 (09) : 1843 - 1850
  • [6] Non-destructive, high-resolution X-ray micro-CT of a Hairy Stalagmite: investigating the structural details of a biogenic speleothem
    G. du Preez
    A. du Plessis
    D. de Beer
    P. Forti
    International Journal of Environmental Science and Technology, 2018, 15 : 1843 - 1850
  • [7] High-resolution non-destructive 3D interrogation of dentin using X-ray nanotomography
    Parkinson, Charles R.
    Sasov, Alexander
    DENTAL MATERIALS, 2008, 24 (06) : 773 - 777
  • [8] Non-destructive high-resolution X-ray micro computed tomography for quantifying dry water particles
    Farhang, Faezeh
    Nguyen, Tuan D.
    Nguyen, Anh V.
    ADVANCED POWDER TECHNOLOGY, 2014, 25 (04) : 1195 - 1204
  • [9] HIGH-RESOLUTION X-RAY TECHNIQUES
    LAL, K
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1981, 19 (09) : 854 - 862
  • [10] X-ray scattering techniques in non destructive testing
    Duvauchelle, P
    Babot, D
    Peix, G
    Zhu, P
    TRENDS IN NDE SCIENCE AND TECHNOLOGY - PROCEEDINGS OF THE 14TH WORLD CONFERENCE ON NDT (14TH WCNDT), VOLS 1-5, 1996, : 1331 - 1334