Immunochromatographic lateral flow strip for on-site detection of bisphenol A

被引:69
|
作者
Mei, Zhanlong [1 ]
Deng, Yi [1 ]
Chu, Huaqin [2 ]
Xue, Feng [1 ,3 ]
Zhong, Youhao [1 ]
Wu, Jingjing [1 ]
Yang, Huan [1 ]
Wang, Zhichao [1 ]
Zheng, Lei [1 ]
Chen, Wei [1 ]
机构
[1] Hefei Univ Technol, Sch Biotechnol & Food Engn, Hefei 230009, Peoples R China
[2] Jiangnan Univ, Sch Food Sci & Technol, Wuxi 210004, Peoples R China
[3] Jiangsu Entry Exit Inspect & Quarantine Bur, Nanjing 200002, Jiangsu, Peoples R China
关键词
Lateral flow strip; Bisphenol A; On-site detection; Food safety; VISUAL DETECTION; ASSAY; BIOSENSOR; RESIDUES; EXPOSURE; SAMPLES; VIRUS; PAPER;
D O I
10.1007/s00604-012-0930-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed a lateral flow assay (LFA) for the detection of bisphenol A (BPA) in water samples. Antibody against BPA was labeled with gold nanoparticles, and these conjugates were used as the recognition probes for the construction of an LFA strip. The diameter of the gold nanoparticles, the amount of antibody, the pH of the buffer, and the categories of the conjugation pad were optimized. The resulting method has a (visual) detection limit of 5 ppb, and of 0.92 ppb if used in combination with professional software. This LFA displays excellent specificity and was applied to spiked water samples with satisfactory results.
引用
收藏
页码:279 / 285
页数:7
相关论文
共 50 条
  • [1] Immunochromatographic lateral flow strip for on-site detection of bisphenol A
    Zhanlong Mei
    Yi Deng
    Huaqin Chu
    Feng Xue
    Youhao Zhong
    Jingjing Wu
    Huan Yang
    Zhichao Wang
    Lei Zheng
    Wei Chen
    [J]. Microchimica Acta, 2013, 180 : 279 - 285
  • [2] A signal-enhanced lateral flow strip biosensor for ultrasensitive and on-site detection of bisphenol A
    Peng, Xiayu
    Kang, Lichao
    Pang, Fangqin
    Li, Hongmin
    Luo, Ruifeng
    Luo, Xiaoling
    Sun, Fengxia
    [J]. FOOD AND AGRICULTURAL IMMUNOLOGY, 2018, 29 (01) : 216 - 227
  • [3] The Development of a Photothermal Immunochromatographic Lateral Flow Strip for Rapid and Sensitive Detection of Bisphenol A in Food Samples
    Yang Lu
    Qian Wang
    Chuan Zhang
    Shijie Li
    Shilun Feng
    Shuo Wang
    [J]. Food Analytical Methods, 2021, 14 : 127 - 135
  • [4] The Development of a Photothermal Immunochromatographic Lateral Flow Strip for Rapid and Sensitive Detection of Bisphenol A in Food Samples
    Lu, Yang
    Wang, Qian
    Zhang, Chuan
    Li, Shijie
    Feng, Shilun
    Wang, Shuo
    [J]. FOOD ANALYTICAL METHODS, 2021, 14 (01) : 127 - 135
  • [5] A lateral flow strip for on-site detection of homocysteine based on a truncated aptamer
    Wu, Yunqing
    Huang, Tianyu
    Chen, Xin
    Wang, Mingyuan
    Wang, Xiaoli
    Zhang, Yuting
    Zhou, Nandi
    [J]. ANALYTICAL METHODS, 2024, 16 (16) : 2456 - 2463
  • [6] A screening lateral flow immunochromatographic assay for on-site detection of okadaic acid in shellfish products
    Lu, Shi-Ying
    Lin, Chao
    Li, Yan-Song
    Zhou, Yu
    Meng, Xian-Mei
    Yu, Shi-Yu
    Li, Zhao-Hui
    Li, Le
    Ren, Hong-Lin
    Liu, Zeng-Shan
    [J]. ANALYTICAL BIOCHEMISTRY, 2012, 422 (02) : 59 - 65
  • [7] Rapid and Sensitive Immunochromatographic Strip for On-site Detection of Sulfamethazine in Meats and Eggs
    Shim, Won-Bo
    Kim, Jeong-Sook
    Kim, Min-Gon
    Chung, Duck-Hwa
    [J]. JOURNAL OF FOOD SCIENCE, 2013, 78 (10) : M1575 - M1581
  • [8] One-step signal amplified lateral flow strip biosensor for ultrasensitive and on-site detection of bisphenol A (BPA) in aqueous samples
    Mei, Zhanlong
    Qu, Wei
    Deng, Yi
    Chu, Huaqin
    Cao, Jinxuan
    Xue, Feng
    Zheng, Lei
    El-Nezamic, Hani Said
    Wu, Yucheng
    Chen, Wei
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 49 : 457 - 461
  • [9] An immunochromatographic test strip for on-site detection of Ralstonia solanacearum in tobacco leaves and soil
    Tian, Xuehui
    Zhao, Zichen
    Wang, Huimeng
    Qin, Yuling
    Wang, Dongkun
    Li, Yichi
    Wang, Xiaoqiang
    Wang, Limin
    [J]. ANALYTICAL BIOCHEMISTRY, 2022, 641
  • [10] An aptamer based lateral flow strip for on-site rapid detection of ochratoxin A in Astragalus membranaceus
    Zhou, Weilu
    Kong, Weijun
    Dou, Xiaowen
    Zhao, Ming
    Ouyang, Zhen
    Yang, Meihua
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1022 : 102 - 108