Effect of intermittent deployment of an electronic monitoring system on hand hygiene behaviors in healthcare workers

被引:8
|
作者
Pong, Steven [1 ,2 ]
Holliday, Pamela [1 ,3 ]
Fernie, Geoff [1 ,2 ,3 ,4 ]
机构
[1] Toronto Rehabil Inst, iDAPT, Toronto, ON, Canada
[2] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON, Canada
[3] Univ Toronto, Dept Surg, Toronto, ON, Canada
[4] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON, Canada
基金
加拿大健康研究院;
关键词
Healthcare-acquired; Infection control; Compliance; Electronic monitoring; IMPLEMENTATION; INTERVENTIONS; FEEDBACK; NURSES; IMPACT;
D O I
10.1016/j.ajic.2018.08.029
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Improving hand hygiene compliance among healthcare professionals is the most effective way to reduce healthcare-acquired infections. Electronic systems developed to increase hand hygiene performance show promise but might not maintain staff participation over time. In this study, we investigated an intermittent deployment strategy to overcome potentially declining participation levels. Methods: An electronic monitoring system was deployed 3 times at 6-month intervals on a musculoskeletal rehabilitation nursing unit in Toronto. Each deployment lasted 4 consecutive weeks. Each wall-mounted soap and hand rub dispenser was outfitted with an activation counter to assess the impact of system deployments on overall handwashing activity. Results: System deployments took place in October 2016, April 2017, and October 2017. A total of 76,130 opportunities were recorded, with an aggregate hand hygiene performance of 67.43%. A total of 515,156 dispenser activations were recorded. There was a significant increase in aggregate dispenser use with every deployment and a decrease over several weeks following each withdrawal. Participation was high at the beginning of each deployment and declined during each deployment but was restored to a high level with the start of the next deployment. Conclusions: Intermittent deployment of an electronic monitoring intervention counteracts potential declines in participation rates sometimes seen with continuous system use. However, adoption of this strategy requires the acceptance of lower periods of performance between each deployment. (c) 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc.
引用
收藏
页码:376 / 380
页数:5
相关论文
共 50 条
  • [1] EFFECTIVENESS OF ELECTRONIC MONITORING SYSTEM ON HEALTHCARE WORKERS' COMPLIANCE WITH HAND HYGIENE
    Prudhvi, Kalyan
    Javed, Muhammad
    Sadaka, Farid
    [J]. CRITICAL CARE MEDICINE, 2022, 50 (01) : 600 - 600
  • [2] Effectiveness of an electronic hand hygiene monitoring system on healthcare workers' compliance to guidelines
    Al Salman, J. M.
    Hani, S.
    de Marcellis-Warin, N.
    Isa, Fatima
    [J]. JOURNAL OF INFECTION AND PUBLIC HEALTH, 2015, 8 (02) : 117 - 126
  • [3] Electronic Monitoring of Individual Healthcare Workers' Hand Hygiene Event Rate
    Muller, Matthew P.
    Levchenko, Alexander I.
    Ing, Stanley
    Pong, Steven M.
    Fernie, Geoff R.
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2014, 35 (09): : 1189 - 1192
  • [4] Healthcare workers' perceptions and acceptance of an electronic reminder system for hand hygiene
    Blomgren, P-O
    Lytsy, B.
    Hjelm, K.
    Swenne, C. L.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2021, 108 : 197 - 204
  • [5] Comparison of two electronic hand hygiene monitoring systems in promoting hand hygiene of healthcare workers in the intensive care unit
    Xiao Zhong
    Dong-Li Wang
    Li-Hua Xiao
    Lan-Fang Mo
    Qing-Fei Wu
    Yan-Wei Chen
    Xiao-Feng Luo
    [J]. BMC Infectious Diseases, 21
  • [6] Comparison of two electronic hand hygiene monitoring systems in promoting hand hygiene of healthcare workers in the intensive care unit
    Zhong, Xiao
    Wang, Dong-Li
    Xiao, Li-Hua
    Mo, Lan-Fang
    Wu, Qing-Fei
    Chen, Yan-Wei
    Luo, Xiao-Feng
    [J]. BMC INFECTIOUS DISEASES, 2021, 21 (01)
  • [7] Healthcare workers' attitudes towards hand-hygiene monitoring technology
    Tarantini, C.
    Brouqui, P.
    Wilson, R.
    Griffiths, K.
    Patouraux, P.
    Peretti-Watel, P.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2019, 102 (04) : 413 - 418
  • [8] Effect of electronic real-time prompting on hand hygiene behaviors in health care workers
    Pong, Steven
    Holliday, Pamela
    Fernie, Geoff
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2018, 46 (07) : 768 - 774
  • [9] Hand hygiene compliance in healthcare workers
    Randle, J.
    Clarke, M.
    Storr, J.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2006, 64 (03) : 205 - 209
  • [10] Intelligent Recommendation System for Assessing Hand Hygiene of Healthcare Workers
    Yevtushenko, Valeriia
    Railian, Maryna
    Chumachenko, Tetyana
    [J]. INTEGRATED COMPUTER TECHNOLOGIES IN MECHANICAL ENGINEERING-2023, VOL 1, ICTM 2023, 2024, 1008 : 290 - 300