FOULING OF HEAT EXCHANGER TUBES IN PULVERIZED-COAL-FIRED COMBUSTION CHAMBERS

被引:0
|
作者
Korytnyi, Efim [1 ]
Berman, Yuli [1 ]
Davidson, Boris [1 ]
Perelman, Miron [1 ]
Saveliev, Roman [1 ]
Bar-Ziv, Ezra [1 ]
机构
[1] Ben Gurion Univ Negev, IL-84105 Beer Sheva, Israel
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Fouling is a major concern in coal-fired power plants caused by fly ash deposit on the heat exchanger tubes that decreases the overall heat transfer coefficient to water-steam mixture. Fouling has been characterized by weakly bound-loose form, which may be removed by various methods, such as soot-blowing, blast, and sand blowing. We have carried out experimental and modeling work on fouling to develop a methodology by which the thermal conductivity of the ash deposit would be determined in a way similar to the fouling process prevailing in real systems. For that we used tubes identical in material, diameter and temperature to those used in many utility boilers. In the experimental work we placed a tube in an axially symmetric 50 kW furnace, and tested fouling from three coals, bituminous and sub-bituminous. We also developed a dynamic model for the prediction of the ash deposition growth and its heat resistance. Comparison of the model prediction and experimental results yielded satisfactory fit. Consequently, thermal resistance of heat exchanger tuber with ash deposit of those coals was determined.
引用
收藏
页码:37 / 40
页数:4
相关论文
共 50 条
  • [1] COMBUSTION EXPERIMENTS USING A PULVERIZED-COAL-FIRED SUPERHEATER
    HORN, G
    CSABA, J
    STREET, PJ
    [J]. JOURNAL OF THE INSTITUTE OF FUEL, 1966, 39 (311): : 521 - &
  • [2] Dynamic modeling and control for pulverized-coal-fired oxy-combustion boiler island
    Jin, Bo
    Zhao, Haibo
    Zheng, Chuguang
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2014, 30 : 97 - 117
  • [3] AN ASSESSMENT OF PARTICLE RADIATION IN A PULVERIZED-COAL-FIRED BOILER
    STEWARD, FR
    TRIVIC, DN
    [J]. JOURNAL OF THE INSTITUTE OF ENERGY, 1989, 62 (452): : 138 - 146
  • [4] Exergy Analysis of a 600 MWe Oxy-combustion Pulverized-Coal-Fired Power Plant
    Xiong, Jie
    Zhao, Haibo
    Zheng, Chuguang
    [J]. ENERGY & FUELS, 2011, 25 (08) : 3854 - 3864
  • [5] Simulation Study of an 800 MWe Oxy-combustion Pulverized-Coal-Fired Power Plant
    Xiong, Jie
    Zhao, Haibo
    Chen, Meng
    Zheng, Chuguang
    [J]. ENERGY & FUELS, 2011, 25 (05) : 2405 - 2415
  • [6] Thermoeconomic cost analysis of a 600 MWe oxy-combustion pulverized-coal-fired power plant
    Xiong, Jie
    Zhao, Haibo
    Zheng, Chuguang
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2012, 9 : 469 - 483
  • [7] A PROPOSED ONLINE EFFICIENCY METHOD FOR PULVERIZED-COAL-FIRED BOILERS
    ROUGHTON, JE
    [J]. JOURNAL OF THE INSTITUTE OF ENERGY, 1980, 53 (414): : 20 - 24
  • [8] Dynamic Simulation and Control Design for Pulverized-Coal-Fired Oxy-Combustion Power Plants
    Jin, Bo
    Zhao, Haibo
    Zheng, Chuguang
    [J]. CLEAN COAL TECHNOLOGY AND SUSTAINABLE DEVELOPMENT, 2016, : 325 - 333
  • [9] BEHAVIOUR OF SULPHUR AND CHLORINE COMPOUNDS IN PULVERIZED-COAL-FIRED BOILERS
    HALSTEAD, WD
    [J]. JOURNAL OF THE INSTITUTE OF FUEL, 1969, 42 (344): : 344 - &
  • [10] EFFECT OF FUEL CHARACTERISTICS AND EXCESS COMBUSTION AIR ON SULPHURIC ACID FORMATION IN A PULVERIZED-COAL-FIRED BOILER
    LEE, GK
    FRIEDRIC.FD
    MITCHELL, ER
    [J]. JOURNAL OF THE INSTITUTE OF FUEL, 1967, 40 (320): : 397 - &