Dose distribution in electron-irradiated PMMA:: effect of dose and geometry

被引:5
|
作者
Mehta, K
Fuochi, PG
Kovács, A
Lavalle, M
Hargittai, P
机构
[1] Int Atom Energy Agcy, A-1400 Vienna, Austria
[2] CNR, Ist Frae, I-40126 Bologna, Italy
[3] Chem Res Ctr, Inst Isotopes & Surface Chem, Budapest, Hungary
关键词
D O I
10.1016/S0969-806X(99)00302-3
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Depth-dose distributions for an electron beam are generally determined with either a stack irradiation geometry or a wedge (generally with an angle of about 50 degrees-60 degrees) made from an electrically-conducting material (such as, aluminium) or a non-conducting material (such as, PMMA). If the non-conducting wedge is thicker than the electron range, the stored charge in the material could influence the measured depth-dose distribution. This effect was investigated for 7-MeV electrons for PMMA with the wedge angle varying from 0 degrees to 60 degrees. The maximum-to-surface dose ratio was used as a characteristic parameter of the shape of the distribution. The depth-dose distribution measured by a dosimetry film placed inside the wedge-pair was similar to the standard shape when the wedge angle was larger than about 55 degrees (dose ratio similar to 1.5). However, as the angle was decreased, this ratio sharply increased almost linearly up to about 15 degrees, and then leveled off at about 3. We also studied the effect of the surface dose on this dose ratio for the wedge angle of 0 degrees, when we found that the ratio increased with the dose. Both of these effects can be explained by the presence of the electrostatic field around the dosimetry film due to stored charge in the non-conducting PMMA. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:773 / 779
页数:7
相关论文
共 50 条
  • [1] DOSE ERRORS IN ELECTRON-IRRADIATED PLASTIC PHANTOMS
    GALBRAITH, DM
    RAWLINSON, JA
    MUNRO, P
    [J]. JOURNAL OF THE CANADIAN ASSOCIATION OF RADIOLOGISTS-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1984, 35 (01): : 98 - 98
  • [2] DOSE DISTRIBUTIONS IN ELECTRON-IRRADIATED PLASTIC TUBING
    MILLER, A
    PEDERSEN, WB
    [J]. RADIATION PHYSICS AND CHEMISTRY, 1981, 18 (5-6): : 967 - 973
  • [3] DIFFICULTIES IN OBTAINING UNIFORM DOSE DISTRIBUTION THROUGHOUT ELECTRON-IRRADIATED PLASTIC MOULDINGS
    MCCANN, JD
    ROGERS, F
    [J]. NATURE, 1963, 200 (491) : 1195 - &
  • [4] A Model for Dose Dependence of the Void Swelling in Electron-Irradiated Alloys
    Ge, Wei
    Zhao, Shijun
    Wang, Chenxu
    Liu, Haocheng
    Su, Yue
    Huang, Jia
    Gao, Zhiying
    Xue, Jianming
    Wang, Yugang
    [J]. METALS, 2022, 12 (02)
  • [5] DOSE ERRORS DUE TO CHARGE STORAGE IN ELECTRON-IRRADIATED PLASTIC PHANTOMS
    GALBRAITH, DM
    RAWLINSON, JA
    MUNRO, P
    [J]. MEDICAL PHYSICS, 1984, 11 (02) : 197 - 203
  • [6] SPACE-CHARGE ACCUMULATION IN ELECTRON-IRRADIATED PMMA
    BOYEV, SG
    TYUTNEV, AP
    [J]. JOURNAL OF ELECTROSTATICS, 1991, 26 (02) : 175 - 185
  • [7] DOSE-DEPENDENCY AND RECOVERY BEHAVIOR OF TRANSPORT PROPERTIES OF ELECTRON-IRRADIATED TELLURIUM
    SAFFERT, R
    GMELIN, E
    LANDWEHR, G
    [J]. JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1978, 11 (13): : 2711 - 2722
  • [8] Dose rate effect on internal friction and structural transformations in electron-irradiated carbon-armored composites
    Zaikin, Yu. A.
    Aimuratov, D. B.
    Al-Sheikhly, M.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2007, 76 (8-9) : 1399 - 1403
  • [9] DOSE AND TEMPERATURE-DEPENDENCE OF VOID SWELLING IN ELECTRON-IRRADIATED STAINLESS-STEEL
    HISHINUMA, A
    KATANO, Y
    SHIRAISHI, K
    [J]. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1977, 14 (10) : 723 - 730
  • [10] THEORETICAL AND EXPERIMENTAL INVESTIGATION OF DOSE ENHANCEMENT DUE TO CHARGE STORAGE IN ELECTRON-IRRADIATED PHANTOMS
    RAWLINSON, JA
    BIELAJEW, AF
    MUNRO, P
    GALBRAITH, DM
    [J]. MEDICAL PHYSICS, 1984, 11 (06) : 814 - 821