Contact and non-contact thermometry in the milk acquisition process

被引:2
|
作者
Karas, I [1 ]
Gálik, R [1 ]
机构
[1] Slovenska Polnohospodarska Univ, Mech Fak, Katedra Mech Zivocisnev Potravinarskej Vyroby, Kalvaria 3, Nitra, Slovakia
关键词
temperatures; non-contact thermometer; mammary gland; milking house;
D O I
10.17221/4264-CJAS
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Temperatures of the northern wall, ceiling and floor of a 2 x 12 milking house as well as of a waiting area in front of the milking house were measured for 24 hours a day in the winter season with an average external daily temperature of -8.6degreesC. The influence of low external temperatures on the temperatures of cows' mammary glands was measured with a non-contact thermometer RAYNGER ST 6 equipped with laser. The analysis showed that the low external temperatures and insufficiently warmed external walls [average 24-hour temperatures: (t(st) = +1.32degreesC), ceiling (t(s) = +2.65degreesC), floor (t(p) = +3.29degreesC)] as well as the waiting area in front of the milking house (t(d) = +1.9degreesC) produced unsuitable temperature conditions despite of the use of heaters in the milking house, resulting in the undercooling of mammary glands and the traumatising of dairy cows. The temperatures of mammary glands of tested dairy cows were evaluated by a multifactor analysis of variance. The time and place of measuring were statistically significant on the significance level 0.05. The F-test value for the factor of time was 12.342, with probability 0.0007. The F-test value for the place of temperature measuring was 1061.979, probability 0.0000. Among the equations of curves of the dependences of teat end temperature on the milking time, the closest seemed to be the logarithmic function with determination index R-2 = 0.7404.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [1] Non-contact phosphor thermometry for process control
    Cates, MR
    Beshears, DL
    Allison, SW
    [J]. OPTICAL INSPECTION AND MICROMEASUREMENTS, 1996, 2782 : 125 - 131
  • [2] A Nickel–Carbon Eutectic Cell for Contact and Non-contact Thermometry
    Renato Nunes Teixeira
    Antônio Carlos Baratto
    [J]. International Journal of Thermophysics, 2007, 28 : 1993 - 2001
  • [3] Non-Contact Infrared Thermometry in Febrile Infants
    Thiagarajan, Srinivasan
    Balaji, Rajeshwar
    Pothapregada, Sriram
    [J]. INDIAN PEDIATRICS, 2020, 57 (09) : 857 - 858
  • [4] Comparison of non-contact infrared thermometry and rectal thermometry in cats
    Nutt, Kelly R.
    Levy, Julie K.
    Tucker, Sylvia J.
    [J]. JOURNAL OF FELINE MEDICINE AND SURGERY, 2016, 18 (10) : 798 - 803
  • [5] Non-Contact Infrared Thermometry in Febrile Infants
    Srinivasan Thiagarajan
    Rajeshwar Balaji
    Sriram Pothapregada
    [J]. Indian Pediatrics, 2020, 57 (9) : 857 - 858
  • [6] A non-contact ammeter using phosphor thermometry
    Shope, DA
    Mahajan, SM
    [J]. PROCEEDINGS OF THE THIRTY-FOURTH SOUTHEASTERN SYMPOSIUM ON SYSTEM THEORY, 2002, : 184 - 187
  • [7] A nickel-carbon eutectic cell for contact and non-contact thermometry
    Teixeira, Renato Nunes
    Baratto, Antonio Carlos
    [J]. INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2007, 28 (06) : 1993 - 2001
  • [8] NON-CONTACT TEST SIGNAL ACQUISITION
    ETTINGER, GM
    SHOOTER, LT
    TILLIER, M
    [J]. MICROPROCESSORS AND MICROSYSTEMS, 1982, 6 (02) : 69 - 71
  • [9] Non-contact thermometry in the Optical Technology Division at NIST
    Gibson, CE
    Yoon, HW
    Tsai, BK
    Johnson, BC
    Saunders, RD
    [J]. THERMOSENSE XXIII, 2001, 4360 : 333 - 341
  • [10] Non-contact thermometry in the milking stopping control system
    Karas, I
    Gálik, R
    [J]. CZECH JOURNAL OF ANIMAL SCIENCE, 2005, 50 (05) : 196 - 200