Comparison of Toric Intraocular Lens Alignment Between Femtosecond Laser-Assisted Capsular Marking and Manual Corneal Marking

被引:4
|
作者
Cao, Danmin [1 ,2 ]
Xu, Yanxue [2 ]
Wang, Yong [1 ,2 ]
机构
[1] Wuhan Univ, Aier Eye Hosp, Wuhan, Peoples R China
[2] Cent South Univ, Aier Sch Ophthalmol, Changsha, Peoples R China
关键词
CATARACT; ASTIGMATISM; SURGERY; CYCLOROTATION; MISALIGNMENT; ACCURACY; OUTCOMES; SYSTEM;
D O I
10.3928/1081597X-20200602-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare toric intraocutar tens (IOL) alignment between femtosecond laser-assisted capsular marking and manual. corneal marking. METHODS: This study prospectively included 72 consecutive eyes (from 72 patients) with cataract and anterior corneal astigmatism of 1.00 diopter (D) or greater that underwent femtosecond laser-assisted cataract surgery with implantation of a toric IOL. These eyes were randomly categorized into two groups based on the IOL alignment method. The femtosecond laser capsular marking group included 36 eyes with capsular markers using the latest femtosecond laser platform. The manual marking group included 36 eyes with manual corneal markers. The preservation of the markers was assessed. Visual acuity and refractive outcomes, as well. as deviation from the target axis, were evaluated. RESULTS: In the femtosecond laser capsular marking group, all capsular markers were retained for at Least 3 months. In the manual marking group, 22.2% of the corneal markers disappeared within 1 month and all markers disappeared within 3 months. At 1 month postoperatively, the mean magnitudes of refractive astigmatism were -0.41 +/- 0.26 and -0.45 +/- 0.31 D (P = .81), and the uncorrected distance visual acuities were 0.07 +/- 0.06 and 0.07 +/- 0.05 logMAR (P= .56) in the femtosecond laser capsular marking and manual marking groups, respectively. The misalignment of the toric IOL within 1 hour postoperatively was 1.5 degrees +/- 1.4 degrees in the femtosecond laser capsular marking group and 4.4 degrees +/- 2.1 degrees in the manual marking group (P < .01). The deviation from the target axis of implantation was 1.6 degrees +/- 1.3 degrees in the femtosecond Laser capsular group and 4.8 degrees +/- 2.5 degrees in the manual marking group (P < .01) at 1 month postoperatively. CONCLUSIONS: IOL misalignment was significantly tower in the femtosecond laser-assisted capsular marking group than in the manual corneal marking group. In addition, the longterm preservation of the capsular marker is helpful in evaluating the rotation of the toric IOL.
引用
收藏
页码:536 / +
页数:8
相关论文
共 50 条
  • [1] Laser-assisted marking for toric intraocular lens alignment
    Dick, H. Burkhard
    Schultz, Tim
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01): : 7 - 10
  • [2] Effect of corneal marking features on toric intraocular lens alignment
    Aytogan, Hasan
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (07) : 1653 - 1658
  • [3] Effect of corneal marking features on toric intraocular lens alignment
    Hasan Aytogan
    [J]. International Ophthalmology, 2020, 40 : 1653 - 1658
  • [4] Verion digital marking versus smartphone-assisted manual marking and isolated manual marking in toric intraocular lens implantation
    Khatib, Zain Irfan
    Haldipurkar, Suhas S.
    Shetty, Vijay
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (03) : 455 - +
  • [5] Intraoperative capsular marking for toric intraocular lens placement
    Sethi, Harinder Singh
    Naik, Mayuresh P.
    [J]. TAIWAN JOURNAL OF OPHTHALMOLOGY, 2020, 10 (04) : 298 - 301
  • [6] Iris Registration Capsulotomy Marking Versus Manual Marking for Toric Intraocular Lens Alignment in Cataract Surgery
    Chen, Qingzhong
    Zhang, Guangbin
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 221 : 97 - 104
  • [7] Manual vs Femtosecond Laser-Assisted Cataract Surgery with Toric Intraocular Lens Implantation
    Lockwood, Ames C.
    Perez-Straziota, Claudia
    Waldron, Rhonda G.
    Randleman, James Bradley
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [8] Rotational slit-beam marking: an advanced manual corneal astigmatic marking method for toric intraocular lens implantation
    Wu, Qianru
    Liu, Yinan
    Cai, Hongyuan
    Zhang, Chun
    Chen, Xiaoyong
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (11) : 3115 - 3125
  • [9] Rotational slit-beam marking: an advanced manual corneal astigmatic marking method for toric intraocular lens implantation
    Qianru Wu
    Yinan Liu
    Hongyuan Cai
    Chun Zhang
    Xiaoyong Chen
    [J]. International Ophthalmology, 2020, 40 : 3115 - 3125
  • [10] Femtosecond laser-assisted refractive capsulorhexis - Precise capsulotomy with accurate toric intraocular lens alignment
    Kaur, Manpreet
    Titiyal, Jeewan Singh
    Shaikh, Farin
    Rani, Deeksha
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (11) : 2562 - +