Comparison of matrix-solid phase dispersion and liquid-solid extraction connected with solid-phase extraction in the quantification of selected furanocoumarins from fruits of Heracleum leskowii by high performance liquid chromatography

被引:17
|
作者
Oniszczuk, Anna [1 ]
Waksmundzka-Hajnos, Monika [1 ]
Skaicka-Wozniak, Krystyna [2 ]
Glowniak, Kazimierz [2 ]
机构
[1] Med Univ Lublin, Dept Inorgan Chem, PL-20093 Lublin, Poland
[2] Med Univ Lublin, Dept Pharmacognosy, Med Plant Unit, PL-20093 Lublin, Poland
关键词
Matrix solid-phase dispersion; Liquid-solid extraction; Solid-phase extraction; Heracleum leskowii; Furanocoumarins; High performance liquid chromatography; YIELD; PUVA;
D O I
10.1016/j.indcrop.2013.07.015
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
In this study, we compared a novel application of matrix solid-phase dispersion (MSPD) methodology and classical liquid-solid extraction (LSE) connected with solid-phase extraction (SPE) for the determination of furanocoumarins from Heracleum leskowii fruits. Fruits of H. leskowii contain the following furanocoumarins: umbelliferon, xanthotoxin, angelicin, isopimpinellin, bergapten, imperatorin, isoimperatorin. Several dispersants, eluents and sample to sorbent mass ratio were examined during the optimization of the process in order to obtain the best selectivity and yield. Quantitative analysis was carried out by high performance liquid chromatography with diode array detector (HPLC-DAD). The method was validated. The calibration curves for all standards were linear over the concentration range 10-100 mu g/mL. The correlation coefficients of all calibration curves were R-2 > 0.9990. LOD and LOQ values ranged from 2.97 mu g/mL to 10.82 mu g/mL, and from 9.03 mu g/mL to 38.32 mu g/mL respectively. The recoveries of the LSE-SPE and MSPD method were in the range of 94.04-102.31% and 92.43-96.27%, respectively. The relative standard deviation (RSD%), as a measure of repeatability, was lower than 5.88% for MSPD and 5.09% for LSE-SPE. MSPD extraction method was compared to the classic analytical method combining liquid-solid extraction with solid-phase extraction. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:131 / 136
页数:6
相关论文
共 50 条
  • [1] Comparison of Matrix Solid-Phase Dispersion and Liquid-Solid Extraction Methods Followed by Solid-Phase Extraction in the Analysis of Selected Furanocoumarins from Pimpinella Roots by HPLC-DAD
    Oniszczuk, A.
    Waksmundzka-Hajnos, M.
    Podgorski, R.
    Nowak, R.
    Zukiewicz-Sobczak, W.
    Blicharski, T.
    [J]. ACTA CHROMATOGRAPHICA, 2015, 27 (04) : 687 - 696
  • [2] Simultaneous determination of phenolic acids and linear furanocoumarins in fruits of Libanotis dolichostyla by solid-phase extraction and high performance liquid chromatography
    Zgórka, G
    Glowniak, K
    [J]. PHYTOCHEMICAL ANALYSIS, 1999, 10 (05) : 268 - 271
  • [3] Matrix Solid-Phase Dispersion versus Ultrasound Assisted Extraction with Solid-Phase Extraction in the HPLC Analysis of Furanocoumarins from Fruits of Archangelica officinalis Hoffm.
    Oniszczuk, Anna
    Skalicka-Wozniak, Krystyna
    Oniszczuk, Tomasz
    Waksmundzka-Hajnos, Monika
    Glowniak, Kaziemirz
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2014, 25 (07) : 1166 - 1171
  • [4] Determination of Three Carotenoids in Microalgae by Matrix Solid-Phase Dispersion Extraction and High-Performance Liquid Chromatography
    Gaowa Jin
    Yanming Liu
    Song Xue
    Yingying Meng
    Jingyu Yan
    Fan Yang
    Zhimou Guo
    Jianhua Zhu
    Xinmiao Liang
    [J]. Chromatographia, 2019, 82 : 1593 - 1601
  • [5] Analysis of patulin in apple products by liquid–liquid extraction, solid phase extraction and matrix solid-phase dispersion methods: a comparative study
    Ri-Na Wu
    Feng-Lan Han
    Jie Shang
    Hong Hu
    Lei Han
    [J]. European Food Research and Technology, 2009, 228 : 1009 - 1014
  • [6] Determination of Three Carotenoids in Microalgae by Matrix Solid-Phase Dispersion Extraction and High-Performance Liquid Chromatography
    Jin, Gaowa
    Liu, Yanming
    Xue, Song
    Meng, Yingying
    Yan, Jingyu
    Yang, Fan
    Guo, Zhimou
    Zhu, Jianhua
    Liang, Xinmiao
    [J]. CHROMATOGRAPHIA, 2019, 82 (11) : 1593 - 1601
  • [7] Determination of pyrethroids in porcine tissues by matrix solid-phase dispersion extraction and high-performance liquid chromatography
    Cheng, Jianhua
    Liu, Miao
    Yu, Yong
    Wang, Xiupin
    Zhang, Hanqi
    Ding, Lan
    Jin, Haiyan
    [J]. MEAT SCIENCE, 2009, 82 (04) : 407 - 412
  • [8] Determination of sulfonamides in livers using matrix solid-phase dispersion extraction high-performance liquid chromatography
    Zhang, Yupu
    Xu, Xu
    Qi, Xiao
    Gao, Wenquan
    Sun, Shuo
    Li, Xiaotian
    Jiang, Chengfei
    Yu, Aimin
    Zhang, Hanqi
    Yu, Yong
    [J]. JOURNAL OF SEPARATION SCIENCE, 2012, 35 (01) : 45 - 52
  • [9] Quantification of antihistamine acrivastine in plasma by solid-phase extraction and high-performance liquid chromatography
    Collins, Benjamin R.
    Gu, Xiaochen
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (01) : 293 - 297
  • [10] Separation of Acylglycerols from Biodiesel by High Performance Liquid Chromatography and Solid-Phase Extraction
    de Andrade, Debora F.
    Mazzei, Jose L.
    d'Avila, Luiz A.