A New Method for Scheimpflug Camera Calibration

被引:0
|
作者
Legarda, Aritz [1 ]
Izaguirre, Alberto [1 ]
Arana, Nestor [1 ]
Iturrospe, Aitzol [1 ]
机构
[1] Univ Mondragon, CIS Dept, Arrasate Mondragon 20500, Spain
关键词
SELF-CALIBRATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An easy way to achieve higher depth of field in a camera-laser configuration is to tilt the image sensor respect to the lens plane, such that the image plane, laser plane and the lens plane intersect in a unique line (Scheimpflug condition [1]). If something has to be measured with this kind of cameras, a proper camera calibration must be done. The usual calibration methods are not valid in this case because they are based on the pin-hole camera model, this model being valid only for normal cameras, i.e. cameras that have the image plane and the lens plane parallel. Thus, a new camera model and its respective calibration must be developed, which includes the Scheimplug angle in the intrinsic camera parameters. In this article, the new camera model and its calibration are defined. Experimental results indicate that using this calibration cameras under Scheimpflug condition can be accurately calibrated.
引用
收藏
页码:76 / 80
页数:5
相关论文
共 50 条
  • [1] A General Imaging Model Based Method for Scheimpflug Camera Calibration
    Sun Cong
    Liu Haibo
    Chen Shengyi
    Shang Yang
    [J]. ACTA OPTICA SINICA, 2018, 38 (08)
  • [2] Review of Calibration Methods for Scheimpflug Camera
    Sun, Cong
    Liu, Haibo
    Jia, Mengna
    Chen, Shengyi
    [J]. JOURNAL OF SENSORS, 2018, 2018
  • [3] Generic Scheimpflug camera model and its calibration
    Zhang, Xu
    Zhou, Tao
    [J]. 2015 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2015, : 2264 - 2270
  • [4] Scheimpflug Camera Calibration Using Lens Distortion Model
    Fasogbon, Peter
    Duvieubourg, Luc
    Macaire, Ludovic
    [J]. PROCEEDINGS OF INTERNATIONAL CONFERENCE ON COMPUTER VISION AND IMAGE PROCESSING, CVIP 2016, VOL 1, 2017, 459 : 159 - 169
  • [5] On-site calibration method for an underwater stereoscopic camera system based on Scheimpflug principle
    Shao, Mingwei
    Li, Yang
    Zhang, Lingkun
    Ma, Hailong
    [J]. JOURNAL OF OPTICS-INDIA, 2024,
  • [6] Intrinsic camera calibration equipped with Scheimpflug optical device
    Fasogbon, Peter
    Duvieubourg, Luc
    Lacaze, Pierre-Antoine
    Macaire, Ludovic
    [J]. TWELFTH INTERNATIONAL CONFERENCE ON QUALITY CONTROL BY ARTIFICIAL VISION, 2015, 9534
  • [7] A new camera calibration method for robotic applications
    Kim, JS
    Kweon, IS
    [J]. IROS 2001: PROCEEDINGS OF THE 2001 IEEE/RJS INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-4: EXPANDING THE SOCIETAL ROLE OF ROBOTICS IN THE NEXT MILLENNIUM, 2001, : 778 - 783
  • [8] A New Calibration Method for linear CCD camera
    Zhao, Xia
    Liu, Bin
    Yang, Chunhui
    [J]. 2010 SYMPOSIUM ON SECURITY DETECTION AND INFORMATION PROCESSING, 2010, 7 : 290 - 296
  • [9] New Calibration Method of Plenoptic Camera Using CCD Camera Model
    Kim, Song-Ran
    Jeong, Min-Chang
    Kang, Hyun-Soo
    [J]. 2018 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS (ICCE), 2018,
  • [10] Camera self-calibration in Scheimpflug condition for air flow investigation
    Louhichi, Hanene
    Fournel, Thierry
    Lavest, Jean Marc
    Ben Aissia, Habib
    [J]. ADVANCES IN VISUAL COMPUTING, PT 2, 2006, 4292 : 891 - 900