Imaging Interferometer (IIM) aboard Chang'E-1 is a Fourier transform imaging spectrometer, with goals to analyze the abundance and distribution of chemical elements on the lunar surface. IIM data suffer from various degradations, which will lead to misleading interpretations of IIM data and inaccuracy of subsequent applications. In this paper, we introduced a noise reduction method based on low-rank matrix decomposition theory. The restoration results are expected to have a better performance in image quality and spectral signatures according to visual and quantitative assessments. Meanwhile, we analyze the characteristic of the noise separated from UM data using top spectral view of noise cube. The preliminary analysis of the noise characteristics contribute to optimize the data preprocessing of HM data such as spectrum reconstruction and radiometric correction.
引用
下载
收藏
页码:148 / 153
页数:6
相关论文
共 50 条
  • [1] A preliminary experience in the use of Chang'E-1 IIM data
    Wu, Yunzhao
    Zheng, Yongchun
    Zou, Yongliao
    Chen, Jun
    Xu, XiSheng
    Tang, Zesheng
    Xu, Aoao
    Yan, Bokun
    Gan, Fuping
    Zhang, Xia
    PLANETARY AND SPACE SCIENCE, 2010, 58 (14-15) : 1922 - 1931
  • [2] Photometric correction and in-flight calibration of Chang' E-1 Interference Imaging Spectrometer (IIM) data
    Wu, Yunzhao
    Besse, Sebastien
    Li, Jian-Yang
    Combe, Jean-Philippe
    Wang, Zhenchao
    Zhou, Xianfeng
    Wang, Chao
    ICARUS, 2013, 222 (01) : 283 - 295
  • [3] Lunar titanium abundance characterization using Chang'E-1 IIM data
    WANG XianMin* & NIU RuiQing Institute of Geophysics and Geomatics
    Science China(Physics,Mechanics & Astronomy), 2012, (01) : 170 - 178
  • [4] Lunar titanium abundance characterization using Chang'E-1 IIM data
    Wang XianMin
    Niu RuiQing
    SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY, 2012, 55 (01) : 170 - 178
  • [5] Information Extraction of the Chang'E-1 Interference Imaging Spectrometer (IIM) 2C Data
    Wang Xiang
    Chen Jian-ping
    Li Jian-feng
    Shi Rui
    Wu Zhao
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (04) : 1145 - 1150
  • [6] Lunar titanium abundance characterization using Chang’E-1 IIM data
    XianMin Wang
    RuiQing Niu
    Science China Physics, Mechanics and Astronomy, 2012, 55 : 170 - 178
  • [7] Refinement of lunar TiO2 analysis with multispectral features of Chang’E-1 IIM data
    Xianmin Wang
    Peimin Zhu
    Astrophysics and Space Science, 2013, 343 : 33 - 44
  • [8] Refinement of lunar TiO2 analysis with multispectral features of Chang'E-1 IIM data
    Wang, Xianmin
    Zhu, Peimin
    ASTROPHYSICS AND SPACE SCIENCE, 2013, 343 (01) : 33 - 44
  • [9] Lunar absolute reflectance as observed by Chang'E-1 Imaging Interferometer
    Zhang Jiang
    Ling ZongCheng
    Liu JianZhong
    Wu ZhongChen
    Li Bo
    Ni YuHeng
    SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY, 2015, 58 (08)
  • [10] Lunar absolute reflectance as observed by Chang’E-1 Imaging Interferometer
    Jiang Zhang
    ZongCheng Ling
    JianZhong Liu
    ZhongChen Wu
    Bo Li
    YuHeng Ni
    Science China Physics, Mechanics & Astronomy, 2015, 58