JCO criticality accident as POST-LOCA: Poor structure induced loss of organizational control accident
被引:0
|
作者:
Furuhama, Y
论文数: 0引用数: 0
h-index: 0
机构:
Tokyo Elect Power Co Ltd, Nucl Power R&D Ctr, Human Factors Grp, Tsurumi Ku, Yokohama, Kanagawa 2308510, JapanTokyo Elect Power Co Ltd, Nucl Power R&D Ctr, Human Factors Grp, Tsurumi Ku, Yokohama, Kanagawa 2308510, Japan
Furuhama, Y
[1
]
机构:
[1] Tokyo Elect Power Co Ltd, Nucl Power R&D Ctr, Human Factors Grp, Tsurumi Ku, Yokohama, Kanagawa 2308510, Japan
Some problems in operation and business management of JCO have been studied as background factors of the criticality accident. Open information about business conditions of JCO suggests that the cause of the accident is not so simple as to be attributed only to economic pressure, but includes immanent problems in JCO. We investigate the problems from five viewpoints, organization of safety management, system of operation management, activities for business improvement, risk awareness, and restructuring of business, and discuss the effects and causality of background factors as well as remedies for them.