National reference doses for common radiographic, fluoroscopic and dental X-ray examinations in the UK

被引:160
|
作者
Hart, D. [1 ]
Hillier, M. C. [1 ]
Wall, B. F. [1 ]
机构
[1] Hlth Protect Agcy, Radiat Protect Div, Didcot OX11 0RQ, Oxon, England
来源
BRITISH JOURNAL OF RADIOLOGY | 2009年 / 82卷 / 973期
关键词
D O I
10.1259/bjr/12568539
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The National Patient Dose Database (NPDD) is maintained by the Radiation Protection Division of the Health Protection Agency. The latest review of the database analysed the data collected from 316 hospitals over a 5-year period to the end of 2005. The information supplied amounted to a total of 23 000 entrance surface dose measurements and 57 000 dose-area product measurements for single radiographs, and 208 000 dose-area product measurements along with 187 000 fluoroscopy times for diagnostic examinations or interventional procedures. In addition, patient dose data for dental X-ray examinations were included for the first time in the series of 5-yearly reviews. This article presents a summary of a key output from the NPDD national reference doses. These are based on the third quartile values of the dose distributions for 30 types of diagnostic X-ray examination and 8 types of interventional procedure on adults, and for 4 types of X-ray examination on children. The reference doses are approximately 16% lower than the corresponding values in the previous (2000) review, and are typically less than half the values of the original UK national reference doses that were derived from a survey in the mid-1980s. This commentary suggests that two of the national reference doses from the 2000 review be retained as diagnostic reference levels because the older sample size was larger than for the 2005 review. No clear evidence could be found for the use of digital imaging equipment having a significant effect on dose.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 50 条
  • [1] PATIENT DOSES IN COMMON DIAGNOSTIC X-RAY EXAMINATIONS
    Metaxas, Vasileios, I
    Messaris, Gerasimos A.
    Lekatou, Aristea N.
    Petsas, Theodore G.
    Panayiotakis, George S.
    RADIATION PROTECTION DOSIMETRY, 2019, 184 (01) : 12 - 27
  • [2] Radiation Doses of Common Dental Radiographic Examinations: A Review
    Brooks, Sharon L.
    ACTA STOMATOLOGICA CROATICA, 2008, 42 (03) : 207 - 217
  • [3] SOME OBSERVATIONS ON SKIN AND ORGAN DOSES DURING X-RAY FLUOROSCOPIC EXAMINATIONS
    TOLE, NM
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (688): : 381 - 383
  • [4] Slovenian national survey of doses to patients undergoing X-ray examinations
    Fortuna, T
    Zdesar, U
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 3, 1996, : C398 - C400
  • [5] REQUIREMENTS IN DESIGN OF AN X-RAY TABLE FOR FLUOROSCOPIC EXAMINATIONS
    BERRIDGE, FR
    BRITISH JOURNAL OF RADIOLOGY, 1971, 44 (518): : 150 - &
  • [6] Radiation doses from some common paediatric X-ray examinations in Sudan
    Suliman, I. I.
    Elshiekh, E. H. A.
    RADIATION PROTECTION DOSIMETRY, 2008, 132 (01) : 64 - 72
  • [7] Evaluation of the Entrance Surface Doses (ESD) for common diagnostic X-ray examinations
    Alomairy, Nada
    Hadi, Dareen
    Al-Zaid, Amna
    Fasikh, Rawan
    Arif, Raneem
    Al-Hazmi, Rawan
    Kharizy, Ali
    Alyami, Ali
    Hummdy, Ahmed
    Shubayr, Nasser
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2023, 16 (04)
  • [8] DOSES TO VERTEBRAL MARROW DURING COMMON X-RAY EXAMINATIONS IN CLINICAL SITUATIONS
    SEIDLITZ, L
    MARGULIS, AR
    INVESTIGATIVE RADIOLOGY, 1974, 9 (06) : 419 - 424
  • [9] Control of effective doses in X-ray examinations
    Stavitskii R.V.
    Zhanina T.V.
    Murashov A.I.
    Kovalev A.S.
    Biomedical Engineering, 1999, 33 (2) : 97 - 103
  • [10] Estimation of patient doses for common diagnostic X-ray examinations in Latvian hospitals, analysis of radiographic techniques and comparison with European guidelines
    Bogucarskis, K
    Salmins, A
    Gfirtner, H
    Anatschkowa, E
    RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 176 - 179