Electron beam test of key elements of the laser-based calibration system for the muon g-2 experiment

被引:14
|
作者
Anastasi, A. [1 ,3 ]
Basti, A. [14 ]
Bedeschi, F. [14 ]
Bartolini, M. [14 ]
Cantatore, G. [4 ,5 ,8 ]
Cauz, D. [4 ,5 ,10 ]
Corradi, G. [1 ]
Dabagov, S. [1 ,18 ,19 ]
Di Sciascio, G. [7 ]
Di Stefano, R. [6 ,11 ]
Driutti, A. [4 ,5 ,10 ]
Escalante, O. [9 ]
Ferrari, C. [1 ,2 ]
Fienberg, A. T. [13 ]
Fioretti, A. [1 ,2 ]
Gabbanini, C. [1 ,2 ]
Gioiosa, A. [16 ,17 ]
Hampai, D. [1 ]
Hertzog, D. W. [13 ]
Iacovacci, M. [6 ,9 ]
Karuza, M. [4 ,5 ,12 ]
Kaspar, J. [13 ]
Liedl, A. [1 ]
Lusiani, A. [14 ,15 ]
Marignetti, F. [6 ,11 ]
Mastroianni, S. [6 ]
Moricciani, D. [7 ]
Pauletta, G. [4 ,5 ,10 ]
Piacentino, G. M. [16 ,17 ]
Raha, N. [7 ]
Rossi, E. [1 ]
Santi, L. [4 ,5 ]
Venanzoni, G. [1 ]
机构
[1] Ist Nazl Fis Nucl, Lab Nazl Frascati, Via E Fermi 40, I-00044 Frascati, Italy
[2] UOS Pisa, CNR, Ist Nazl Ott, Via Moruzzi 1, I-56124 Pisa, Italy
[3] Univ Messina, Dipartimento MIFT, Messina, Italy
[4] Ist Nazl Fis Nucl, Sez Trieste, Trieste, Italy
[5] GC Udine, Udine, Italy
[6] Ist Nazl Fis Nucl, Sez Napoli, Naples, Italy
[7] Ist Nazl Fis Nucl, Sez Roma Tor Vergata, Rome, Italy
[8] Univ Trieste, Trieste, Italy
[9] Univ Naples Federico II, Naples, Italy
[10] Univ Udine, Udine, Italy
[11] Univ Cassino, Cassino, Italy
[12] Univ Rijeka, Rijeka, Croatia
[13] Univ Washington, Box 351560, Seattle, WA 98195 USA
[14] Ist Nazl Fis Nucl, Sez Pisa, Pisa, Italy
[15] Scuola Normale Super Pisa, Pisa, Italy
[16] Ist Nazl Fis Nucl, Sez Lecce, Lecce, Italy
[17] Univ Molise, Pesche, Italy
[18] Lebedev Phys Inst, Moscow, Russia
[19] NRNU MEPhI, Moscow, Russia
关键词
Electromagnetic calorimeter; Laser; Muon;
D O I
10.1016/j.nima.2016.10.047
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report the test of many of the key elements of the laser-based calibration system for muon g - 2 experiment E989 at Fermilab. The test was performed at the Laboratori Nazionali di Frascati's Beam Test Facility using a 450 MeV electron beam impinging on a small subset of the final g - 2 lead-fluoride crystal calorimeter system. The calibration system was configured as planned for the E989 experiment and uses the same type of laser and most of the final optical elements. We show results regarding the calorimeter's response calibration, the maximum equivalent electron energy which can be provided by the laser and the stability of the calibration system components.
引用
收藏
页码:86 / 91
页数:6
相关论文
共 26 条
  • [1] The Fermilab Muon g-2 experiment: laser calibration system
    Karuza, M.
    Anastasi, A.
    Basti, A.
    Bedeschi, F.
    Bartolini, M.
    Cantatore, G.
    Cauz, D.
    Corradi, G.
    Dabagov, S.
    Di Sciascio, G.
    Di Stefano, R.
    Driutti, A.
    Escalante, O.
    Ferrari, C.
    Fioretti, A.
    Gabbanini, C.
    Gioiosa, A.
    Hampai, D.
    Iacovacci, M.
    Liedl, A.
    Lusiani, A.
    Marignetti, F.
    Mastroianni, S.
    Moricciani, D.
    Nath, A.
    Pauletta, G.
    Piacentino, G. M.
    Raha, N.
    Santi, L.
    Venanzoni, G.
    [J]. JOURNAL OF INSTRUMENTATION, 2017, 12
  • [2] The calibration system of the Muon g-2 experiment
    Driutti, A.
    Basti, A.
    Bedeschi, F.
    Cantatore, G.
    Cauz, D.
    Corradi, G.
    Dabagov, S.
    Di Falco, S.
    Di Sciascio, G.
    Di Stefano, R.
    Donati, S.
    Escalante, O.
    Ferrari, C.
    Fioretti, A.
    Gabbanini, C.
    Gioiosa, A.
    Hampai, D.
    Iacovacci, M.
    Incagli, M.
    Karuza, M.
    Lusiani, A.
    Marignetti, F.
    Mastroianni, S.
    Moricciani, D.
    Nath, A.
    Paulett, G.
    Piacentino, G. M.
    Raha, N.
    Santi, L.
    Smith, M.
    Sorbara, M.
    Venanzoni, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 98 - 101
  • [3] The laser-based gain monitoring system of the calorimeters in the Muon g-2 experiment at Fermilab
    Anastasi, A.
    Basti, A.
    Bedeschi, F.
    Boiano, A.
    Bottalico, E.
    Cantatore, G.
    Cauz, D.
    Chapelain, A. T.
    Corradi, G.
    Dabagov, S.
    Di Falco, S.
    Di Meo, P.
    Di Sciascio, G.
    Di Stefano, R.
    Donati, S.
    Driutti, A.
    Ferrari, C.
    Fienberg, A. T.
    Fioretti, A.
    Gabbanini, C.
    Gibbons, L. K.
    Gioiosa, A.
    Girotti, P.
    Hampai, D.
    Hempstead, J. B.
    Hertzog, D. W.
    Iacovacci, M.
    Incagli, M.
    Karuza, M.
    Kaspar, J.
    Khaw, K. S.
    Lusiani, A.
    Marignetti, F.
    Mastroianni, S.
    Miozzi, S.
    Nath, A.
    Pauletta, G.
    Piacentino, G. M.
    Raha, N.
    Santi, L.
    Smith, M.
    Sorbara, M.
    Sweigart, D. A.
    Venanzoni, G.
    [J]. JOURNAL OF INSTRUMENTATION, 2019, 14
  • [4] The monitoring electronics of the laser calibration system in the Muon g-2 experiment
    Anastasi, A.
    Anastasio, A.
    Avino, S.
    Bedeschi, F.
    Boiano, A.
    Cantatore, G.
    Cauz, D.
    Ceravolo, S.
    Corradi, G.
    Dabagov, S.
    Di Falco, S.
    Di Meo, S.
    Donati, S.
    Driutti, A.
    Di Sciascio, G.
    Di Stefano, R.
    Escalante, O.
    Ferrari, C.
    Fioretti, A.
    Gabbanini, C.
    Gagliardi, G.
    Gioiosa, A.
    Hampai, D.
    Iacovacci, M.
    Incagli, M.
    Karuza, M.
    Lusiani, A.
    Marignetti, F.
    Mastroianni, S.
    Moricciani, D.
    Nath, A.
    Pauletta, G.
    Piacentino, G. M.
    Raha, N.
    Santi, L.
    Smith, M. W.
    Venanzoni, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 372 - 373
  • [5] Test of candidate light distributors for the muon (g-2) laser calibration system
    Anastasi, A.
    Babusci, D.
    Baffigi, F.
    Cantatore, G.
    Cauz, D.
    Corradi, G.
    Dabagov, S.
    Di Sciascio, G.
    Di Stefano, R.
    Ferrari, C.
    Fienberg, A. T.
    Fioretti, A.
    Fulgentini, L.
    Gabbanini, C.
    Gizzi, L. A.
    Hampai, D.
    Hertzog, D. W.
    Iacovacci, M.
    Karuza, M.
    Kaspar, J.
    Koester, P.
    Labate, L.
    Mastroianni, S.
    Moricciani, D.
    Pauletta, G.
    Santi, L.
    Venanzoni, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 788 : 43 - 48
  • [6] The Readout Controller for the Calibration System of the Muon g-2 Experiment
    Mastroianni, S.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (04) : 1033 - 1039
  • [7] Laser calibration system for the Muon g - 2 Experiment at Fermilab
    Nath, A.
    [J]. NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2019, 42 (04):
  • [8] The laser control of the muon g-2 experiment at Fermilab
    Anastasi, A.
    Anastasio, A.
    Avino, S.
    Basti, A.
    Bedeschi, F.
    Boiano, A.
    Cantatore, G.
    Cauz, D.
    Ceravolo, S.
    Corradi, G.
    Dabagov, S.
    Di Meo, P.
    Driutti, A.
    Di Sciascio, G.
    Di Stefano, R.
    Escalante, O.
    Ferrari, C.
    Fienberg, A. T.
    Fioretti, A.
    Gabbanini, C.
    Gagliardi, G.
    Gioiosa, A.
    Hampai, D.
    Hertzog, D. W.
    Iacovacci, M.
    Incagli, M.
    Karuza, M.
    Kaspar, J.
    Lusiani, A.
    Marignetti, F.
    Mastroianni, S.
    Moricciani, D.
    Nath, A.
    Pauletta, G.
    Piacentino, G. M.
    Raha, N.
    Santi, L.
    Smith, M. W.
    Venanzoni, G.
    [J]. JOURNAL OF INSTRUMENTATION, 2018, 13
  • [9] Muon g-2 calibration system data flow
    Anastasia, A.
    Anastasio, A.
    Avino, S.
    Bedeschi, F.
    Boiano, A.
    Cantatore, G.
    Cauz, D.
    Ceravolo, S.
    Corradi, G.
    Dabagov, S.
    Di Falco, S.
    Di Meo, P.
    Donati, S.
    Driutti, A.
    Di Sciascio, G.
    Di Stefano, R.
    Escalante, O.
    Ferrari, C.
    Fioretti, A.
    Gabbanini, C.
    Gagliardi, G.
    Gioiosa, A.
    Hampai, D.
    Iacovacci, M.
    Incagli, M.
    Karuza, M.
    Lusiani, A.
    Marignetti, F.
    Mastroianni, S.
    Moricciani, D.
    Nath, A.
    Pauletta, G.
    Piacentino, G. M.
    Raha, N.
    Santi, L.
    Smith, M. W.
    Venanzoni, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 335 - 336
  • [10] The slow control system of the muon g-2 experiment
    Stillman, A
    [J]. PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 1996, : 2211 - 2213