Full-scale removal of DNAPL constituents using steam-enhanced extraction and electrical resistance heating

被引:75
|
作者
Heron, G
Carroll, S
Nielsen, SG
机构
[1] TerraTherm Inc, Keene, CA 93531 USA
[2] Water Management Consultants Inc, Reno, NV USA
[3] NIRAS Consulting Engineers & Planners, DK-8000 Aarhus, Denmark
来源
关键词
D O I
10.1111/j.1745-6592.2005.00060.x
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
In 2003, the United States Department of Energy completed a full-scale non-aqueous phase liquid (NAPL) remediation of Area A of the Northeast Site at the Young-Rainey STAR Center, Largo, Florida. Area A covered an area of 930 m 2 (10,000 square feet) and extended to a depth of 10.7 m (35 feet), representing a total cleanup volume of 9930 m 3 (12,960 cubic yards). The site was contaminated with similar to 2500 kg (5500 lb) of NAPL constituents such as trichloroethylene, cis-1,2-dichloroethylene, methylene chloride, toluene, and petroleum hydrocarbons. The site consists of a fine-grained sand aquifer underlain by a Hawthorn clay at 9 m (30 feet) depth. The upper 1.5 m (5 feet) of this clay formed part of the remediation volume, as dense non - aqueous phase liquid was present in this layer. The site was remediated using a combination of steam-enhanced extraction and electrical resistance heating. Operations lasted 4.5 months. The site was heated to the target temperatures within 6 weeks, at which time the mass removal rate increased more than 1000-fold. After the target volume had been heated to or near boiling temperatures, pressure cycles were used to increase the mass removal rates, until a final phase of diminishing returns was reached. Postoperational sampling of soil and ground water at randomly selected locations showed the concentrations of all contaminants of concern (COC) to be well below the remedial goals. The majority of the ground water samples were below maximum contaminant level (MCL) for all the COC. The estimate of volatile organic contaminant (VOC) mass removed from the site (1130 kg 2500 lb) agreed well with the estimate of VOC present before operation (1170 kg 2580 lb). The postoperational sampling showed that similar to 0.5 kg (1 pound) of VOCs remained in the remedial volume, and showed remedial efficiencies of between 99.85% and 99.99% for the four chemicals of concern. Since the postoperational sampling shows all concentrations to be below or close to ground water MCLs, the thermal remedy may be satisfactory for site closure without a polishing phase.
引用
收藏
页码:92 / 107
页数:16
相关论文
共 50 条
  • [1] DNAPL/LNAPL remediation in clay till using steam-enhanced extraction
    Adams, TV
    Smith, GJ
    [J]. FIRST INTERNATIONAL CONFERENCE ON REMEDIATION OF CHLORINATED AND RECALCITRANT COMPOUNDS, VOL 5: PHYSICAL, CHEMICAL AND THERMAL TECHNOLOGIES, 1998, : 103 - 108
  • [2] Combination of steam-enhanced extraction and electrical resistance heating for efficient remediation of perchloroethylene-contaminated soil:Coupling merits and energy consumption
    Rui Yue
    Zhikang Chen
    Liujun Liu
    Lipu Yin
    Yicheng Qiu
    Xianhui Wang
    Zhicheng Wang
    Xuhui Mao
    [J]. Frontiers of Environmental Science & Engineering., 2022, 16 (11) - 129
  • [3] Combination of steam-enhanced extraction and electrical resistance heating for efficient remediation of perchloroethylene-contaminated soil: Coupling merits and energy consumption
    Yue, Rui
    Chen, Zhikang
    Liu, Liujun
    Yin, Lipu
    Qiu, Yicheng
    Wang, Xianhui
    Wang, Zhicheng
    Mao, Xuhui
    [J]. FRONTIERS OF ENVIRONMENTAL SCIENCE & ENGINEERING, 2022, 16 (11)
  • [4] Combination of steam-enhanced extraction and electrical resistance heating for efficient remediation of perchloroethylene-contaminated soil: Coupling merits and energy consumption
    Rui Yue
    Zhikang Chen
    Liujun Liu
    Lipu Yin
    Yicheng Qiu
    Xianhui Wang
    Zhicheng Wang
    Xuhui Mao
    [J]. Frontiers of Environmental Science & Engineering, 2022, 16
  • [5] In Situ Thermal Remediation of DNAPL and LNAPL Using Electrical Resistance Heating
    Beyke, Gregory
    Fleming, David
    [J]. REMEDIATION-THE JOURNAL OF ENVIRONMENTAL CLEANUP COSTS TECHNOLOGIES & TECHNIQUES, 2005, 15 (03): : 5 - 22
  • [6] Enhanced biological phosphorus removal in a semi full-scale SBBR
    Arnz, P
    Arnold, E
    Wilderer, PA
    [J]. WATER SCIENCE AND TECHNOLOGY, 2001, 43 (03) : 167 - 174
  • [7] Enhancing DNAPL removal from low permeability zone using electrical resistance heating with pulsed direct current
    Geng, Zhuning
    Liu, Bo
    Li, Guanghe
    Zhang, Fang
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2021, 413
  • [8] Demonstration of enhanced nutrient removal at two full-scale SBR plants
    Peters, M
    Newland, M
    Seviour, T
    Broom, T
    Bridle, T
    [J]. WATER SCIENCE AND TECHNOLOGY, 2004, 50 (10) : 115 - 120
  • [9] Metabolic modelling of full-scale enhanced biological phosphorus removal sludge
    Lanham, Ana B.
    Oehmen, Adrian
    Saunders, Aaron M.
    Carvalho, Gilda
    Nielsen, Per H.
    Reis, Maria A. M.
    [J]. WATER RESEARCH, 2014, 66 : 283 - 295
  • [10] Removal of antibiotic resistance genes in four full-scale membrane bioreactors
    Li, Bing
    Qiu, Yong
    Li, Ji
    Liang, Peng
    Huang, Xia
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2019, 653 : 112 - 119