Fast in situ gamma spectroscopy using hand-held spectrometer with NaI probe

被引:4
|
作者
Gugula, Szymon [1 ]
Kozak, Krzysztof [1 ]
Mazur, Jadwiga [1 ]
Grzadziel, Dominik [1 ]
Mroczek, Mariusz [1 ]
机构
[1] Inst Nucl Phys PAN, Radzikowskiego 152, PL-31342 Krakow, Poland
关键词
Gamma spectroscopy; NaI detector; In situ measurements; Efficiency calibration; AIRBORNE; SOIL;
D O I
10.1016/j.jenvrad.2017.09.018
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this work a hand-held spectrometer InSpector 1000 with NaI (Tl) 2 '' x 2 '' detector has been adapted to fast in situ gamma-ray spectroscopy. Two specially designed mounting stands with shielding have been built, allowing conducting measurements in different geometries. Three particular geometries (NW, IS50, 1500) have been chosen for efficiency calibration and further study. The first one (NW) is intended for small environmental samples (volume ca 140 cm(3)) collected on site. IS50 geometry is a typical in situ geometry meant for radioactivity measurements in soil with detector pointed towards the ground. In this geometry the probe is shielded and mounted 50 cm above the soil surface. The new proposed geometry 1500 is designed in the way that the detector is inserted directly into the soil in order to increase the counting efficiency. The methods of efficiency calibration involved using calibration standards (in NW geometry) and the results obtained in previous in situ measurements with InSpector 2000 portable spectrometer with HPGe detector and ISOCS (TM) Shield Systems, which is routinely used in environmental measurements. NW geometry turned out to be useful for natural radioisotopes concentrations (K-40, U-238 and Th-232), which significantly exceed typical values of those concentrations observed in Poland. Both 1550 and IS00 geometries are applicative for quick (2 h long measurement) evaluation of typical concentrations of K, U and Th in soils. The newly proposed geometry IS00 is superior as it showed lower detection limits and uncertainties as well as its handling was far easier than of IS50. Authors have proven that hand-held spectrometer InSpector 1000, together with mounting stands and shielding, can be successfully used for fast in situ gamma-spectroscopy. Its relatively small weight and good mobility are additional assets. Moreover, detailed procedures for measurements in each geometry have been developed to conduct such analyses properly. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:87 / 94
页数:8
相关论文
共 50 条
  • [1] HAND-HELD GAMMA-RAY SPECTROMETER GUN
    WAECHTER, DA
    WOLF, MA
    UMBARGER, CJ
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) : 301 - 303
  • [2] Hand-held gamma probe or hand-held miniature gamma camera for minimally invasive parathyroidectomy: competition, evolution or synergy?
    Domenico Rubello
    Giuliano Mariani
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 162 - 164
  • [3] Hand-held gamma probe or hand-held miniature gamma camera for minimally invasive parathyroidectomy: competition, evolution or synergy?
    Rubello, Domenico
    Mariani, Giuliano
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (02) : 162 - 164
  • [4] A simple hand-held spectrometer
    Daw, HA
    [J]. AMERICAN JOURNAL OF PHYSICS, 1997, 65 (03) : 251 - 254
  • [5] PEROPERATIVE LOCALIZATION OF METASTASES WITH A HAND-HELD GAMMA-PROBE
    ADAMS, S
    HOVY, L
    BAUM, RP
    ADAMS, M
    MAUL, FD
    KAHLAWITZSCH, H
    ZICHNER, L
    JONAS, D
    HOR, G
    [J]. NUKLEARMEDIZIN, 1995, 34 (04) : 161 - 164
  • [6] Direction-Sensitive Hand-Held Gamma-Ray Spectrometer
    Mukhopadhyay, Sanjoy
    [J]. HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XV, 2013, 8852
  • [7] Imaging of Osteoarthritis using a Hand-held Terahertz Probe
    Kan, Kanis W. C.
    Lee, Wing-Sze
    Cheung, W. H.
    Pickwell-MacPherson, Emma
    [J]. 2009 34TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES, VOLS 1 AND 2, 2009, : 83 - +
  • [8] Evaluation of hand-held gamma camera with 1-mm NaI(Tl) pixels
    Yamaguchi, Y
    MacDonald, LR
    Patt, BE
    Iwanczyk, JS
    Aarsvold, JN
    Mintzer, RA
    Alazraki, NP
    Greene, CM
    [J]. PENETRATING RADIATION SYSTEMS AND APPLICATIONS IV, 2002, 4786 : 103 - 113
  • [9] LOCALIZATION BY HAND-HELD GAMMA PROBE OF TUMOR LABELED WITH ANTIBODY COCKTAIL
    SARDI, A
    SIDDIQI, MA
    HINKLE, G
    ROUSSEAU, M
    GERSMAN, M
    HILL, T
    OLSEN, J
    TUTTLE, S
    YOUNG, D
    HOUCHENS, D
    THURSTON, M
    MARTIN, EW
    [J]. JOURNAL OF SURGICAL RESEARCH, 1989, 47 (03) : 227 - 234
  • [10] HAND-HELD ELECTROMAGNET-PROBE
    CRAWFORD, WA
    [J]. AMERICAN MINERALOGIST, 1976, 61 (1-2) : 173 - 173