Monte Carlo calculations of the dose distribution around a commercial gynecologic tandem applicator

被引:14
|
作者
Gifford, KA [1 ]
Mourtada, F [1 ]
Cho, SH [1 ]
Lawyer, A [1 ]
Horton, JL [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
关键词
Monte Carlo simulation; tandem applicator; Cs-137; tip screw;
D O I
10.1016/j.radonc.2005.09.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Dose rate distributions around Fletcher Suit Delclos (FSD) tandem applicators used for intracavitary brachytherapy are usually calculated by assuming each source is a point source and summing the contributions from each of the sources. Consequently, interpellet attenuation and scattering are ignored. Additional error may be introduced because the applicator walls and tip screw are not considered. The focus of this study was a Monte Carlo simulation of a Selectron tandem, verification of the calculations, and presentation of the implications of the point-source approximation for treatment planning. Materials and methods: MCNPX 2.4.k was used to calculate dose rate distributions around straight and curved tandems. The Monte Carlo calculations were verified with radiochromic film. Results: MCNPX calculated dose to within +/- 2% or +/- 2 mm for 97% of the points on the film parallel to the long axis and 98% on a film perpendicular to the long axis of the straight portion of the tandem. The point source approximation overestimated dose by as much as 33% superior to the tip of the tandem as compared to MCNPX. The point source approximation overestimated dose when photons passed through multiple pellets by as much as 18% as compared to MCNPX. Laterally, the dose distribution was not affected greatly. Conclusions: Interpellet attenuation was a dominant factor in determining the distribution along the length of the pellet train. MCNPX calculated doses accurately when the pellets and applicator walls were included in the geometry. The point source approximation is adequate lateral to the tandem. The point source approximation does not calculate dose accurately superior to the tandem or when photons pass through multiple pellets. (c) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:210 / 215
页数:6
相关论文
共 50 条
  • [1] Monte Carlo calculations around a commercial gynecological applicator
    Gifford, K
    Lawyer, A
    Eifel, P
    Jhingran, A
    Horton, J
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1470 - 1470
  • [2] Monte Carlo calculations of radiotherapy dose distributions within and around orthopaedic implants
    Katsifis, Georgio Andrew
    McKenzie, David R.
    Suchowerska, Natalka
    [J]. PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 22 : 123 - 130
  • [3] EGSnrc Monte Carlo calculated dose distribution around brachytherapy sources
    Tuan, Hoang
    Minh Phuoc Dang
    [J]. NUCLEAR MEDICINE AND BIOLOGY, 2022, 108 : S175 - S176
  • [4] Estimation of microscopic dose enhancement factor around gold nanoparticles by Monte Carlo calculations
    Jones, Bernard L.
    Krishnan, Sunil
    Cho, Sang Hyun
    [J]. MEDICAL PHYSICS, 2010, 37 (07) : 3809 - 3816
  • [6] PATIENT-SPECIFIC MONTE CARLO DOSE CALCULATIONS FOR HIGH-DOSE-RATE ENDORECTAL BRACHYTHERAPY WITH SHIELDED INTRACAVITARY APPLICATOR
    Poon, Emily
    Williamson, Jeffrey F.
    Vuong, Te
    Verhaegen, Frank
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (04): : 1259 - 1266
  • [7] A Monte Carlo approach to calculate dose distribution around the lineal brachytherapy sources
    Vieira, JW
    Lima, FRA
    Kramer, R
    [J]. CELLULAR AND MOLECULAR BIOLOGY, 2002, 48 (05) : 445 - 450
  • [8] Fast Monte Carlo dose calculations for brachytherapy
    Rogers, DWO
    Yegin, G
    Taylor, RE
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S17 - S17
  • [9] Monte Carlo Dose Calculations for Radiobiology Studies
    Mahuvava, C.
    Esplen, N.
    Kry, S.
    Bazalova-Carter, M.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [10] Validation of Monte Carlo dose planning calculations by epithermal beam: Dose distribution measurements in phantoms
    Carolan, MG
    Wallace, SA
    Allen, BJ
    Rosenfeld, AB
    Mathur, JN
    Meriaty, HA
    StecherRasmussen, F
    Moss, RL
    Raaijmakers, CPJ
    Konijnenberg, MW
    [J]. CANCER NEUTRON CAPTURE THERAPY, 1996, : 303 - 310