Wide-field digital retinal imaging versus binocular indirect ophthalmoscopy for retinopathy of prematurity screening: a two-observer prospective, randomised comparison

被引:59
|
作者
Dhaliwal, C. [3 ]
Wright, E.
Graham, C. [2 ]
McIntosh, N. [3 ]
Fleck, B. W. [1 ]
机构
[1] Princess Alexandra Eye Pavil, Edinburgh EH3 9HA, Midlothian, Scotland
[2] Western Gen Hosp, Wellcome Clin Res Facil, Edinburgh EH4 2XU, Midlothian, Scotland
[3] Univ Edinburgh, Dept Neonatol, Royal Infirm, Simpsons Ctr Reprod Hlth, Edinburgh, Midlothian, Scotland
关键词
PLUS DISEASE; INTERNATIONAL CLASSIFICATION; TELEMEDICINE; DIAGNOSIS; AGREEMENT; INFANTS; TRIAL; RISK;
D O I
10.1136/bjo.2008.148908
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To compare the diagnostic accuracy of wide-field digital retinal imaging (WFDRI) with the current "gold standard'' of binocular indirect ophthalmoscopy (BIO) for retinopathy of prematurity (ROP) screening examinations. Methods: A consecutive series of premature infants undergoing ROP screening at Edinburgh Royal Infirmary were eligible for recruitment into this prospective, randomised, comparative study. Infants were screened using both WFDRI (Retcam II with neonatal lens) and BIO by two paediatric ophthalmologists who were randomised to the examination technique. Both examiners documented their clinical findings and management plans in a masked fashion. WFDRI eye findings were compared with those of BIO. Results: A total of 81 infants were recruited, and information from 245 eye examinations was analysed. The sensitivity of WFDRI in detecting any stage of ROP, stage 3 ROP and "plus'' disease was 60%, 57% and 80%, respectively, and specificity 91%, 98% and 98%, respectively. The proportional agreement between WFDRI and BIO was 0.96 for detecting stage 3 disease and 0.97 for detecting "plus'' disease. There was very good agreement on management decisions (kappa 0.85). Conclusion: When used in a routine ROP screening setting, a randomised comparison of WFDRI and BIO, WFDRI showed relatively poor sensitivity in detecting mild forms of ROP in the retinal periphery. This resulted in difficulty in making decisions to discharge infants from the screening programme. Sensitivity was better for more severe forms of ROP, but at present WFDRI should be regarded as an adjunct to, rather than a replacement for, BIO in routine ROP screening.
引用
收藏
页码:355 / 359
页数:5
相关论文
共 38 条
  • [1] Pain in neonates during screening for retinopathy of prematurity using binocular indirect ophthalmoscopy and wide-field digital retinal imaging: a randomised comparison
    Dhaliwal, C. A.
    Wright, E.
    McIntosh, N.
    Dhaliwal, K.
    Fleck, B. W.
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2010, 95 (02): : F146 - F148
  • [2] Alternative methods for the screening of retinopathy of prematurity: binocular indirect ophthalmoscopy vs wide-field digital retinal imaging
    M A Sekeroglu
    E Hekimoglu
    H T Sekeroglu
    U Arslan
    [J]. Eye, 2013, 27 : 1053 - 1057
  • [3] Alternative methods for the screening of retinopathy of prematurity: binocular indirect ophthalmoscopy vs wide-field digital retinal imaging
    Sekeroglu, M. A.
    Hekimoglu, E.
    Sekeroglu, H. T.
    Arslan, U.
    [J]. EYE, 2013, 27 (09) : 1053 - 1057
  • [4] Analysis of the parental satisfaction for retinopathy of prematurity screening using binocular indirect ophthalmoscopy versus wide field retinal imaging
    Dhami, Abhinav
    Gupta, Gaurav
    Dhami, Nimrata Bajaj
    Arora, Nishant
    Dhami, Gobinder Singh
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (08) : 2142 - 2145
  • [5] Commentary: Wide-field imaging vs binocular indirect ophthalmoscopy in retinopathy of prematurity screening: Real-world advantages
    Vinekar, Anand
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (08) : 2146 - 2146
  • [6] Efficacy of wide-field digital retinal imaging for retinopathy of prematurity screening
    Dai, Shuan
    Chow, Kent
    Vincent, Andrea
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (01): : 23 - 29
  • [7] Comparison of Digital Imaging Screening and Indirect Ophthalmoscopy for Retinopathy of Prematurity
    El Din, Zahraa Mohamed Ezz
    El Sada, Mohamed Ahmed
    Ali, Aliaa Adel
    Al Husseiny, Khalid
    Yousef, Aly Abdel Rahman
    [J]. INDIAN JOURNAL OF PEDIATRICS, 2015, 82 (01): : 80 - 83
  • [8] Comparison of Digital Imaging Screening and Indirect Ophthalmoscopy for Retinopathy of Prematurity
    Zahraa Mohamed Ezz El Din
    Mohamed Ahmed El Sada
    Aliaa Adel Ali
    Khalid Al Husseiny
    Aly Abdel Rahman Yousef
    [J]. The Indian Journal of Pediatrics, 2015, 82 : 80 - 83
  • [9] Screening for retinopathy of prematurity using wide-field digital retinal imaging: Sensitivity and specificity
    Fielder, AR
    Cocker, KD
    Capone, A
    Trese, MT
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2002, 120 (09) : 1234 - 1234
  • [10] Pain and stress assessment after retinopathy of prematurity screening examination: Indirect ophthalmoscopy versus digital retinal imaging
    Teresa Moral-Pumarega, M.
    Caserio-Carbonero, Sonia
    De-La-Cruz-Bertolo, Javier
    Tejada-Palacios, Pilar
    Lora-Pablos, David
    Pallas-Alonso, Carmen R.
    [J]. BMC PEDIATRICS, 2012, 12