A fast and accurate numerical method for solving simulated moving bed (SMB) chromatographic separation problems

被引:37
|
作者
Lim, YI [1 ]
Jorgensen, SB
机构
[1] Hankyong Natl Univ, Dept Chem Engn, Amseong 456749, Kyonggi Do, South Korea
[2] Tech Univ Denmark, Dept Chem Engn, DK-2800 Lyngby, Denmark
关键词
numerical analysis; space-time CE/SE method; simulated moving bed (SMB); computational parameters; recycle flow treatment; chromatographic adsorption problem;
D O I
10.1016/j.ces.2003.12.026
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Solving simulated moving bed (SMB) chromatography models requires fast and accurate numerical techniques, since their system size computed is large due to multi-columns and multi-components, in addition the axial solution profiles contain steep moving fronts. The space-time conservation element/solution element (CE/SE) method addressed in this study enforces both local and global flux conservation in space and time, and uses a simple stencil structure (two points at the previous time level and one point at the present time level) on staggered space-time grids. Thus, accurate and computationally efficient numerical solutions are obtained. Stable solutions are guaranteed if the Courant-Friedrichs-Lewy (CFL) condition is satisfied. The boundary condition and recycle flow treatments are much simpler than for the time integrator in the framework of the method of lines. Applying the CE/SE method for SMB chromatographic problems, non-dissipative and accurate solutions are obtained and fast calculation is achieved in this study. The effects of two-computational parameters (CFL number and mesh stepsize) on the numerical solution are examined, illustrating two SMB processes whose Peclet and Stanton numbers are different. It is shown that the CFL number affects little the numerical solution under the relatively high Peclet number and low Stanton number but a small mesh stepsize is required to enhance accuracy. As the Peclet number decreases and the Stanton number increases, a lower CFL number is preferable and larger mesh stepsize is permitted. In the case study of the SMB adsorption problems, a large CFL number and sufficient number of mesh points (or small mesh stepsize) are desirable to reduce the calculation time and increase accuracy. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1931 / 1947
页数:17
相关论文
共 50 条
  • [1] The use of simulated moving bed in chromatographic separation: Study of the SMB configuration
    da Silva, EAB
    de Souza, AAU
    Souza, SMAGU
    SEPARATION SCIENCE AND TECHNOLOGY, 2002, 37 (07) : 1489 - 1504
  • [2] Dynamic optimization of a simulated moving bed (SMB) chromatographic separation process
    Garcia, Maria-Sonia G.
    Balsa-Canto, Eva
    Banga, Julio R.
    Wouwer, Alain Vande
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2006, 45 (26) : 9033 - 9041
  • [3] Process modification of SMB (Simulated Moving Bed) for multicomponent separation
    Kim, Jin-Il
    Koo, Yoon-Mo
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2009, 108 : S57 - S57
  • [4] Fast and Accurate Simulation of Simulated Moving Bed Chromatographic Processes with Linear Adsorption Isotherms
    Pishkari, Rojiar
    Kienle, Achim
    30TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, PTS A-C, 2020, 48 : 487 - 492
  • [5] Simulated Moving Bed(SMB) Chromatography Simulation for Loxoprofen Racemates Separation
    Kim, In Ho
    Song, Sung Moon
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2011, 49 (05): : 623 - 627
  • [6] Micro-simulated moving bed (μSMB) systems: A numerical study
    Subramani, Hariprasad J.
    Kurup, Anjushri S.
    Chemical Engineering Journal, 2006, 120 (03): : 169 - 179
  • [7] Micro-simulated moving bed (μSMB) systems:: A numerical study
    Subramani, Hariprasad J.
    Kurup, Anjushri S.
    CHEMICAL ENGINEERING JOURNAL, 2006, 120 (03) : 169 - 179
  • [8] Continuous Chromatographic Separation of Salt From Sugars by Simulated Moving Bed Technology (SMB) Using Orochem Zucchero™ Columns
    Oroskar, Anil R.
    Nair, Rakesh
    LC GC NORTH AMERICA, 2009, : 41 - 41
  • [9] A novel design of simulated moving bed (SMB) chromatography for separation of ketoprofen enantiomer
    Tae Ho Yoon
    Bong Hyun Chung
    In Ho Kim
    Biotechnology and Bioprocess Engineering, 2004, 9 : 285 - 291
  • [10] A novel design of simulated moving bed (SMB) chromatography for separation of ketoprofen enantiomer
    Yoon, TH
    Chung, BH
    Kim, IH
    BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2004, 9 (04) : 285 - 291