Informing urban climate planning with high resolution data: the Hestia fossil fuel CO2emissions for Baltimore, Maryland

被引:10
|
作者
Roest, Geoffrey S. [1 ]
Gurney, K. R. [1 ]
Miller, S. M. [2 ]
Liang, J. [3 ,4 ]
机构
[1] No Arizona Univ, Sch Informat Comp & Cyber Syst, Flagstaff, AZ 86011 USA
[2] Johns Hopkins Univ, Dept Environm Hlth & Engn, Baltimore, MD USA
[3] Arizona State Univ, Sch Life Sci, Tempe, AZ USA
[4] ESRI, Redlands, CA USA
关键词
Fossil fuel; Carbon dioxide; Emissions; Hestia; Baltimore; CO2; EMISSIONS; CARBON MITIGATION; QUANTIFICATION; SCALE; FOOTPRINT;
D O I
10.1186/s13021-020-00157-0
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Background Cities contribute more than 70% of global anthropogenic carbon dioxide (CO2) emissions and are leading the effort to reduce greenhouse gas (GHG) emissions through sustainable planning and development. However, urban greenhouse gas mitigation often relies on self-reported emissions estimates that may be incomplete and unverifiable via atmospheric monitoring of GHGs. We present the Hestia Scope 1 fossil fuel CO2(FFCO2) emissions for the city of Baltimore, Maryland-a gridded annual and hourly emissions data product for 2010 through 2015 (Hestia-Baltimore v1.6). We also compare the Hestia-Baltimore emissions to overlapping Scope 1 FFCO(2)emissions in Baltimore's self-reported inventory for 2014. Results The Hestia-Baltimore emissions in 2014 totaled 1487.3 kt C (95% confidence interval of 1158.9-1944.9 kt C), with the largest emissions coming from onroad (34.2% of total city emissions), commercial (19.9%), residential (19.0%), and industrial (11.8%) sectors. Scope 1 electricity production and marine shipping were each generally less than 10% of the city's total emissions. Baltimore's self-reported Scope 1 FFCO(2)emissions included onroad, natural gas consumption in buildings, and some electricity generating facilities within city limits. The self-reported Scope 1 FFCO(2)total of 1182.6 kt C was similar to the sum of matching emission sectors and fuels in Hestia-Baltimore v1.6. However, 20.5% of Hestia-Baltimore's emissions were in sectors and fuels that were not included in the self-reported inventory. Petroleum use in buildings were omitted and all Scope 1 emissions from industrial point sources, marine shipping, nonroad vehicles, rail, and aircraft were categorically excluded. Conclusions The omission of petroleum combustion in buildings and categorical exclusions of several sectors resulted in an underestimate of total Scope 1 FFCO(2)emissions in Baltimore's self-reported inventory. Accurate Scope 1 FFCO(2)emissions, along with Scope 2 and 3 emissions, are needed to inform effective urban policymaking for system-wide GHG mitigation. We emphasize the need for comprehensive Scope 1 emissions estimates for emissions verification and measuring progress towards Scope 1 GHG mitigation goals using atmospheric monitoring.
引用
收藏
页数:16
相关论文
共 49 条
  • [1] Informing urban climate planning with high resolution data: the Hestia fossil fuel CO2 emissions for Baltimore, Maryland
    Geoffrey S. Roest
    K. R. Gurney
    S. M. Miller
    J. Liang
    [J]. Carbon Balance and Management, 15
  • [2] Vulcan and Hestia: High resolution quantification of fossil fuel CO2 emissions
    Gurney, K. R.
    Zhou, Y.
    Mendoza, D.
    Chandrasekaran, V.
    Geethakumar, S.
    Razlivanov, I.
    Song, Y.
    Godbole, A.
    [J]. 19TH INTERNATIONAL CONGRESS ON MODELLING AND SIMULATION (MODSIM2011), 2011, : 1781 - 1787
  • [3] The Hestia fossil fuel CO2 emissions data product for the Los Angeles megacity (Hestia-LA)
    Gurney, Kevin R.
    Patarasuk, Risa
    Liang, Jianming
    Song, Yang
    O'Keeffe, Darragh
    Rao, Preeti
    Whetstone, James R.
    Duren, Riley M.
    Eldering, Annmarie
    Miller, Charles
    [J]. EARTH SYSTEM SCIENCE DATA, 2019, 11 (03) : 1309 - 1335
  • [5] Mapping urban building fossil fuel CO2 emissions with a high spatial and temporal resolution
    W. Li
    [J]. International Journal of Environmental Science and Technology, 2022, 19 : 1785 - 1798
  • [6] Biofuel burning and human respiration bias on satellite estimates of fossil fuel CO2emissions
    Ciais, P.
    Wang, Y.
    Andrew, R.
    Breon, F. M.
    Chevallier, F.
    Broquet, G.
    Nabuurs, G. J.
    Peters, G.
    McGrath, M.
    Meng, W.
    Zheng, B.
    Tao, S.
    [J]. ENVIRONMENTAL RESEARCH LETTERS, 2020, 15 (07):
  • [7] Industrial growth and CO2emissions in Vietnam: the key role of financial development and fossil fuel consumption
    Ali, Kishwar
    Bakhsh, Satar
    Ullah, Saif
    Ullah, Atta
    Ullah, Sami
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (06) : 7515 - 7527
  • [8] High spatiotemporal resolution urban fossil fuel CO2 emissions mapping and modeling: A pilot study in Indianapolis, Indiana, USA
    Gurney, Kevin R.
    Razlivanov, Igor
    Song, Yang
    Zhou, Yuyu
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 242
  • [9] Urban high-resolution fossil fuel CO2 emissions quantification and exploration of emission drivers for potential policy applications
    Patarasuk, Risa
    Gurney, Kevin Robert
    O'Keeffe, Darragh
    Song, Yang
    Huang, Jianhua
    Rao, Preeti
    Buchert, Martin
    Lin, John C.
    Mendoza, Daniel
    Ehleringer, James R.
    [J]. URBAN ECOSYSTEMS, 2016, 19 (03) : 1013 - 1039
  • [10] Urban high-resolution fossil fuel CO2 emissions quantification and exploration of emission drivers for potential policy applications
    Risa Patarasuk
    Kevin Robert Gurney
    Darragh O’Keeffe
    Yang Song
    Jianhua Huang
    Preeti Rao
    Martin Buchert
    John C. Lin
    Daniel Mendoza
    James R. Ehleringer
    [J]. Urban Ecosystems, 2016, 19 : 1013 - 1039