A gas-filled calorimeter for high intensity beam environments

被引:0
|
作者
Abrams, Robert [1 ]
Ankenbrandt, Charles [1 ]
Flanagan, Gene [1 ]
Hauptman, John [2 ]
Kahn, Steven [1 ]
Lee, Sehwook [2 ]
Notani, Masahiro [1 ]
机构
[1] Muons Inc, Batavia, IL 60510 USA
[2] Iowa State Univ, Ames, IA 50011 USA
关键词
Calorimeter; Cherenkov; radiation tolerant;
D O I
10.1016/j.phpro.2012.02.387
中图分类号
O59 [应用物理学];
学科分类号
摘要
We describe a novel gas-Cherenkov calorimeter, which detects Cherenkov light showers emitted in an array of thin metal tubes or channels filled with gas. The materials are not vulnerable to radiation damage, and the detector is inherently fast and able to operate in high rate environments. Future accelerators such as the ILC and a muon collider will need fast, radiation-tolerant detectors for monitoring beams and beam halos, and detectors are needed that can operate in the presence of high particle rates. Such detectors will also be useful for high rate environments at upgraded facilities such as RHIC, CEBAF II, and at Fermilab's Project X. (C) 2012 Published by Elsevier B.V. Selection and/or peer review under responsibility of the organizing committee for 11.
引用
收藏
页码:364 / 371
页数:8
相关论文
共 50 条
  • [1] Intensity Stabilization of Ionizing Pulses in High-Pressure, Gas-Filled Capillaries
    Gao, Xiaohui
    Patwardhan, Gauri
    Shim, Bonggu
    Popmintchev, Tenio
    Kapteyn, Henry C.
    Murnane, Margaret M.
    Gaeta, Alexander L.
    2016 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2016,
  • [2] Nonlinear beam matching to gas-filled multipass cells
    Hanna, Marc
    Daniault, Louis
    Guichard, Florent
    Daher, Nour
    Delen, Xavier
    Lopez-Martens, Rodrigo
    Georges, Patrick
    OSA CONTINUUM, 2021, 4 (02) : 732 - 738
  • [3] Guiding of high-intensity feratosecond laser pulses in evacuated and gas-filled capillaries
    Lin, JQ
    Nakano, H
    Nishikawa, T
    Ozaki, T
    Oguri, K
    OPTICS COMMUNICATIONS, 2003, 221 (4-6) : 411 - 417
  • [4] Beam intensity monitor based on gas scintillation emitted from helium gas molecules in a gas-filled recoil ion separator
    Kaji, D.
    Morimoto, K.
    Tokanai, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 737 : 19 - 21
  • [5] The impulse strength of solid and gas-filled high
    Gemant, A
    JOURNAL OF THE FRANKLIN INSTITUTE, 1942, 234 : 519 - 533
  • [6] DESIGN OF A GAS-FILLED PARTICLE-BEAM REACTOR CHAMBER
    SWEENEY, MA
    COOK, DL
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (07): : 800 - 801
  • [7] Improved gas-filled hohlraum performance on Nova with beam smoothing
    Kauffman, RL
    Powers, LV
    Dixit, SN
    Glendinning, SG
    Glenzer, SH
    Kirkwood, RK
    Landon, OL
    MacGowan, BJ
    Moody, JD
    Orzechowski, TJ
    Pennington, DM
    Stone, GF
    Suter, LJ
    Turner, RE
    Weiland, TL
    Richard, AL
    Blain, MA
    PHYSICS OF PLASMAS, 1998, 5 (05) : 1927 - 1934
  • [8] On the mechanism of subnanosecond electron beam formation in gas-filled diodes
    Tarasenko, V. F.
    Yakovlenko, S. I.
    Shunailov, S. A.
    Kostyrya, I. D.
    Tkachev, A. N.
    LASER PHYSICS, 2006, 16 (03) : 526 - 533
  • [9] Simulations of a gas-filled helical muon beam cooling channel
    Yonehara, K
    Kaplan, D
    Beard, K
    Bogacz, SA
    Derbenev, Y
    Johnson, R
    Paul, K
    Roberts, T
    2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 3474 - 3476
  • [10] ION-BEAM CHARACTERISTICS OF A GAS-FILLED ACCELERATOR TUBE
    BERG, RS
    BICKES, RW
    BOERS, JE
    SHOPE, LA
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1981, 18 (03): : 983 - 986