A ventilation intervention study in classrooms to improve indoor air quality: the FRESH study

被引:48
|
作者
Rosbach, Jeannette T. M. [1 ,2 ]
Vonk, Machiel [2 ]
Duijm, Frans [2 ]
van Ginkel, Jan T. [3 ]
Gehring, Ulrike [1 ]
Brunekreef, Bert [1 ,4 ]
机构
[1] Univ Utrecht, Inst Risk Assessment Sci, NL-3508 TD Utrecht, Netherlands
[2] Municipal Hlth Serv Groningen, Dept Environm Hlth, NL-9700 AN Groningen, Netherlands
[3] Municipal Hlth Serv IJsselland, Dept Environm Hlth, NL-8001 BL Zwolle, Netherlands
[4] Univ Med Ctr Utrecht, Julius Ctr Hlth Sci & Primary Care, NL-3508 GA Utrecht, Netherlands
关键词
Ventilation; Schools; Carbon dioxide; Indoor air quality; Intervention; CO2; CONCENTRATIONS; HEALTH; PERFORMANCE; SCHOOLS; RATES; ASSOCIATION; RESPONSES;
D O I
10.1186/1476-069X-12-110
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Background: Classroom ventilation rates often do not meet building standards, although it is considered to be important to improve indoor air quality. Poor indoor air quality is thought to influence both children's health and performance. Poor ventilation in The Netherlands most often occurs in the heating season. To improve classroom ventilation a tailor made mechanical ventilation device was developed to improve outdoor air supply. This paper studies the effect of this intervention. Methods: The FRESH study (Forced-ventilation Related Environmental School Health) was designed to investigate the effect of a CO2 controlled mechanical ventilation intervention on classroom CO2 levels using a longitudinal cross-over design. Target CO2 concentrations were 800 and 1200 parts per million (ppm), respectively. The study included 18 classrooms from 17 schools from the north-eastern part of The Netherlands, 12 experimental classrooms and 6 control classrooms. Data on indoor levels of CO2, temperature and relative humidity were collected during three consecutive weeks per school during the heating seasons of 2010 2012. Associations between the intervention and weekly average indoor CO2 levels, classroom temperature and relative humidity were assessed by means of mixed models with random school-effects. Results: At baseline, mean CO2 concentration for all schools was 1335 ppm (range: 763-2000 ppm). The intervention was able to significantly decrease CO2 levels in the intervention classrooms (F (2,10) = 17.59, p < 0.001), with a mean decrease of 491 ppm. With the target set at 800 ppm, mean CO2 was 841 ppm (range: 743-925 ppm); with the target set at 1200 ppm, mean CO2 was 975 ppm (range: 887-1077 ppm). Conclusions: Although the device was not capable of precisely achieving the two predefined levels of CO2, our study showed that classroom CO2 levels can be reduced by intervening on classroom ventilation using a CO2 controlled mechanical ventilation system.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A ventilation intervention study in classrooms to improve indoor air quality: the FRESH study
    Jeannette TM Rosbach
    Machiel Vonk
    Frans Duijm
    Jan T van Ginkel
    Ulrike Gehring
    Bert Brunekreef
    [J]. Environmental Health, 12
  • [2] A comprehensive analysis of the intervention of a fresh air ventilation system on indoor air quality in classrooms
    Chen, Yu-Hao
    Tu, Yen-Pei
    Sung, Shih-Yi
    Weng, Wei-Cheng
    Huang, Hsiao-Lin
    Tsai, Ying, I
    [J]. ATMOSPHERIC POLLUTION RESEARCH, 2022, 13 (04)
  • [3] Classroom ventilation and indoor air qualityresults from the FRESH intervention study
    Rosbach, J.
    Krop, E.
    Vonk, M.
    van Ginkel, J.
    Meliefste, C.
    de Wind, S.
    Gehring, U.
    Brunekreef, B.
    [J]. INDOOR AIR, 2016, 26 (04) : 538 - 545
  • [4] Indoor Air Quality Performance of Ventilation Systems in Classrooms
    Moon, Hyeun Jun
    Sohn, Jong-Ryeul
    Hwang, Taeyon
    [J]. JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2016, 15 (02) : 343 - 348
  • [5] Ventilation strategies to improve indoor air quality
    Luo, Q
    Tang, G
    Huang, W
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 3313 - 3317
  • [6] Study on the impact of fresh air rate on indoor air quality
    Liu, Guodan
    Ye, Bichao
    Hu, Songtao
    Zhang, Changxing
    Zhang, Li
    Zhu, Chun
    [J]. PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 635 - +
  • [7] The effect of ventilation on the indoor air concentration of PCB: An intervention study
    Lyng, Nadja Lynge
    Gunnarsen, Lars
    Andersen, Helle Vibeke
    [J]. BUILDING AND ENVIRONMENT, 2015, 94 : 305 - 312
  • [8] Numerical Study of Classrooms Using Hybrid Ventilation with Fresh Air Cooled by a Tunnel
    Xu Shuhui
    Ma Tianlei
    Wang Zhebin
    [J]. 6TH INTERNATIONAL SYMPOSIUM OF ASIA INSTITUTE OF URBAN ENVIRONMENT: ENERGY CONSERVATION AND CARBON OFF IN ASIA CITY, 2009, : 312 - 317
  • [9] Ventilation for Energy Efficiency and Improved Indoor Air Quality in University Classrooms
    Kumar, Sangeetha
    Nguyen, Annette
    Gayler, Kate
    Madigan, Grace
    Xing, Rachel
    Novoselac, Atila
    [J]. IAQ 2020: INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES, PT 2, 2022,
  • [10] The Effect of Ventilation Strategies on Indoor Air Quality and Energy Consumptions in Classrooms
    Stabile, Luca
    Massimo, Angelamaria
    Canale, Laura
    Russi, Aldo
    Andrade, Alexandro
    Dell'Isola, Marco
    [J]. BUILDINGS, 2019, 9 (05)