Evaluation of the functional obsolescence of building services in European office buildings

被引:17
|
作者
Allehaux, D [1 ]
Tessier, P [1 ]
机构
[1] SETEC Equipements, F-75583 Paris 12, France
关键词
office buildings; functional obsolescence; building services; TOBUS;
D O I
10.1016/S0378-7788(01)00104-9
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
With the support of the TOBUS software, it is now possible to evaluate, in a methodical and rigorous manner, one of the major causes of obsolescence for office buildings. The functional obsolescence is a major parameter affecting technical installations and influences the value of an office building. The tool can be used during an office building audit to examine and assess all the building services which are likely to be found in modern buildings (i.e. heating, ventilating and air conditioning (HVAC) plants, fire fighting services, electrical installations, information networks, building management systems, etc.). The selected quality assessment criteria correspond to the requirements of modem buildings, including compliance with user needs, flexibility, divisibility and maintainability, as well as conformity with building regulations, Moreover, the software is used to pet-form an exhaustive diagnosis of the entire building, including architectural and technical aspects, and supports the user to define and evaluate different scenarios and retrofitting actions, providing the corresponding costs. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 50 条
  • [1] Obsolescence of Green Office Buildings: A Literature Review
    Rodi, Wan Norhishamuddin Wan
    Hwa, Ting Kien
    Said, Ahmad Shahrin
    Mahamood, Nur Medeena
    Abdullah, Mohd Isa
    Abd Rasam, Abd. Rauf
    [J]. INTERNATIONAL ACCOUNTING AND BUSINESS CONFERENCE 2015, IABC 2015, 2015, 31 : 651 - 660
  • [2] Identifying building obsolescence: towards increasing buildings' service life
    Pourebrahimi, Mohammad
    Eghbali, Seyed Rahman
    Roders, Ana Pereira
    [J]. INTERNATIONAL JOURNAL OF BUILDING PATHOLOGY AND ADAPTATION, 2020, 38 (05) : 635 - 652
  • [3] Evaluation of daylighting in office buildings
    Doulos, L.
    Tsangrassoulis, A.
    Topalis, F. V.
    [J]. ENVIRONMENTAL SCIENCE, ECOSYSTEMS AND DEVELOPMENT, 2007, : 368 - +
  • [4] Development of a methodology for selecting office building upgrading solutions based on a test survey in European buildings
    Wittchen, KB
    Brandt, E
    [J]. ENERGY AND BUILDINGS, 2002, 34 (02) : 163 - 169
  • [5] Building Integrated Photovoltaic Retrofitting in Office Buildings
    El Gindi, Salwa
    Abdin, Ahmed Reda
    Hassan, Ayman
    [J]. INTERNATIONAL CONFERENCE - ALTERNATIVE AND RENEWABLE ENERGY QUEST (AREQ 2017), 2017, 115 : 239 - 252
  • [6] Ventilation rates in European office buildings: A review
    Dimitroulopoulou, C.
    Bartzis, J.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2014, 23 (01) : 5 - 25
  • [7] Economic Evaluation of Variable Office Buildings
    Schach, Rainer
    Harzdorf, Anne
    Weller, Cornell
    [J]. ICCREM 2017: REAL ESTATE AND URBANIZATION, 2017, : 1 - 8
  • [8] Evaluation of lighting controls in office buildings
    Doulos, L.
    Tsangrassoulis, A.
    Topalis, F. V.
    [J]. PROCEEDINGS OF THE WSEAS INTERNATIONAL CONFERENCE ON CIRCUITS, SYSTEMS, ELECTRONICS, CONTROL & SIGNAL PROCESSING: SELECTED TOPICS ON CIRCUITS, SYSTEMS, ELECTRONICS, CONTROL & SIGNAL PROCESSING, 2007, : 69 - +
  • [9] Causes of sick building syndrome in German office buildings
    Brasche, S
    Bullinger, M
    Gebhardt, H
    Herzog, V
    Bischof, W
    [J]. GESUNDHEITSWESEN, 2000, 62 (8-9) : A62 - A63
  • [10] GREEN BUILDING RATING FOR OFFICE BUILDINGS - LESSONS LEARNED
    Zuo, Jian
    Xia, Bo
    Chen, Qing
    Pullen, Stephen
    Skitmore, Martin
    [J]. JOURNAL OF GREEN BUILDING, 2016, 11 (02): : 131 - 146