Modelling the variation in rectal dose due to inter-fraction rectal wall deformation in external beam prostate treatments

被引:2
|
作者
Booth, J [1 ]
Zavgorodni, S
机构
[1] Royal Prince Alfred Hosp, Camperdown, NSW 2050, Australia
[2] Univ Adelaide, Adelaide, SA 5005, Australia
[3] Royal Adelaide Hosp, Adelaide, SA 5000, Australia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2005年 / 50卷 / 21期
关键词
D O I
10.1088/0031-9155/50/21/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Prostate radiotherapy inevitably deposits radiation dose in the rectal wall, and the dose delivered to prostate is limited by the expected rectal complications. Accurate evaluation of the rectal dose is non-trivial due to a number of factors. One of these is variation of the shape and position of the rectal wall (with respect to the clinical target volume (CTV)), which may differ daily from that taken during planning CT acquisition. This study uses data currently available in the literature on rectal wall motion to provide estimates of mean population rectal wall dose. The rectal wall geometry is characterized by a population mean radius of the rectum as well as inter-patient and inter-fraction standard deviations in rectum radius. The model is used to evaluate the range of interfraction and inter-patient rectal dose variations. The simulation of individual patients with full and empty rectum in the planning CT scan showed that large variations in rectal dose (> 15 Gy) are possible. Mean calculated dose accounting for treatment and planning uncertainties in the rectal wall surface was calculated as well as the map of planning dose over/underpredictions. It was found that accuracy of planning dose is dependent on the CTV-PTV margin size with larger margins producing more accurate estimates. Over a patient population, the variation in rectal dose is reduced by increasing the number of pre-treatment CT scans.
引用
收藏
页码:5055 / 5074
页数:20
相关论文
共 45 条
  • [1] A geometric model for evaluating the effects of inter-fraction rectal motion during prostate radiotherapy
    Pavel-Mititean, LM
    Rowbottom, CG
    Hector, CL
    Partridge, M
    Bortfeld, T
    Schlegel, W
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12): : 2613 - 2629
  • [2] The impact of a diet protocol on prostate IGRT patients' rectal volumes and their inter-fraction consistency
    Gan, P. Z. H.
    Lin, X.
    Chua, Z. J.
    Pang, P. P. E.
    Hussain, A.
    Teh, J. Y. H.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S584 - S584
  • [3] Inter-fraction error analyses and rectal and bladder volume variations using CBCT in prostate cancer
    Rosa, C.
    Borgia, M.
    Lucarelli, M.
    Fasciolo, D.
    Vinciguerra, A.
    Augurio, A.
    Marcucci, S.
    Caravatta, L.
    Marchioni, M.
    Di Nicola, M.
    Genovesi, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1199 - S1200
  • [4] Inter-Fraction Rectum Motion for Patients with Rectal Cancer Detected by Daily Cone Beam CT
    Lotey, R.
    Yu, N.
    Abdel-Wahab, M.
    Xia, P.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [5] Dosimetric Impact of Inter-Fraction Variations in Bladder Filling and Rectal Emptying in Patients Undergoing Prostate SBRT
    Gorovets, D.
    Lichtenwalner, P.
    Shi, C.
    Borofsky, K. L.
    Parhar, P. K.
    Zelefsky, M. J.
    Chan, M. F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E511 - E511
  • [6] Inter-fraction variation of the heart dose for VMAT post-mastectomy irradiation of chest wall
    Tang, B.
    Kang, S.
    Wang, P.
    Li, J.
    Xin, X.
    Liao, X.
    Ma, J.
    Orlandini, L. C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1117 - S1118
  • [7] Radiological measurements to predict dose variation due to inter-fraction variability in H&N
    Catucci, F.
    Cusumano, D.
    Menna, S.
    D'Aviero, A.
    Di Dio, C.
    Re, A.
    Iezzi, M.
    Piccari, D.
    Quaranta, F.
    Boschetti, A.
    Marras, M.
    Piro, D.
    Votta, C.
    Sanna, E.
    Flore, C.
    Mattiucci, G. C.
    Valentini, V.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1256 - S1257
  • [8] An analysis of inter-fraction prostate deformation relative to implanted fiducial markers using finite element modelling
    Jaffray, D
    Brock, K
    Nichol, A
    Moseley, D
    Catton, C
    Warde, P
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S229 - S229
  • [9] Investigation of the changes in the prostate, bladder, and rectal wall sizes during external beam radiotherapy
    Tanaka, Osamu
    Seike, Kensaku
    Taniguchi, Takuya
    Ono, Kousei
    Matsuo, Masayuki
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2019, 24 (02) : 204 - 207
  • [10] EFFECTS OF PROSTATE-RECTUM SEPARATION ON RECTAL DOSE FROM EXTERNAL BEAM RADIOTHERAPY
    Susil, Robert C.
    McNutt, Todd R.
    DeWeese, Theodore L.
    Song, Danny
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (04): : 1251 - 1258