Contrast Enhancement of Luminescence Images via Point-Spread Deconvolution

被引:0
|
作者
Walter, Daniel [1 ]
Liu, Anyao [1 ]
Franklin, Evan [1 ]
Macdonald, Daniel [1 ]
Mitchell, Bernhard [2 ]
Trupke, Thorsten [2 ,3 ]
机构
[1] Australian Natl Univ, Ctr Sustainable Energy Syst, Canberra, ACT 0200, Australia
[2] Univ New South Wales, Sch Photovoltaic & Renewable Energy Engn, Kensington, NSW, Australia
[3] BT Imaging, Surry Hills, NSW, Australia
关键词
point-spread function; deconvolution; luminescence imaging;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
We investigate the impact of point-spread in the silicon CCD sensor of a BT Imaging LIS-R1 luminescence imaging system. It is found that an experimental definition of the point-spread function allows for a significant restoration of CCD point-spread to be achieved. A comparison with short-pass filtering is performed, demonstrating that point-spread will still have a measurable influence on image quality while reducing the luminescence signal and increasing the relative noise level. An implementation of point-spread deconvolution is presented at a multi-crystalline silicon grain boundary, illustrating a practical enhancement of resolution in a typical high-contrast scenario. The characteristics of the point-spread presented here are specific to the experimental apparatus investigated, but the procedure described is universally applicable.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Blind deconvolution for symmetric point-spread functions
    Lou, Yifei
    Zhang, Bin
    Wang, Jing
    Jiang, Ming
    [J]. 2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 3459 - 3462
  • [2] Myopic deconvolution of adaptive optics images by use of object and point-spread function power spectra
    Conan, JM
    Mugnier, LM
    Fusco, T
    Michau, V
    Rousset, G
    [J]. APPLIED OPTICS, 1998, 37 (21): : 4614 - 4622
  • [3] Myopic deconvolution of adaptive optics images by use of object and point-spread function power spectra
    Conan, Jean-Marc
    Mugnier, Laurent M.
    Fusco, Thierry
    Michau, Vincent
    Rousset, Gérard
    [J]. Applied Optics, 1998, 37 (21): : 4614 - 4622
  • [4] Blind deconvolution of images and small-extent point-spread functions using resultant matrices
    Yagle, AE
    [J]. 2000 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL III, PROCEEDINGS, 2000, : 786 - 788
  • [5] A Study of the Point-spread Function in SDSS Images
    Xin, Bo
    Ivezic, Zeljko
    Lupton, Robert H.
    Peterson, John R.
    Yoachim, Peter
    Jones, R. Lynne
    Claver, Charles F.
    Angeli, George
    [J]. ASTRONOMICAL JOURNAL, 2018, 156 (05):
  • [6] Myopic deconvolution of adaptive optics images by use of object and point-spread function power spectra: comment
    Kopeika, NS
    [J]. APPLIED OPTICS, 2000, 39 (15) : 2412 - 2414
  • [7] Myopic deconvolution of adaptive optics images by use of object and point-spread function power spectra: Comment
    Kopeika, Norman S.
    [J]. Applied Optics, 2000, 39 (15): : 2412 - 2414
  • [8] RESOLUTION ENHANCEMENT IN FLUORESCENCE IMAGES BY DECONVOLUTION WITH AXIALLY ASYMMETRIC POINT SPREAD FUNCTIONS
    SCALETTAR, BA
    SWEDLOW, JR
    SEDAT, JW
    AGARD, A
    [J]. BIOPHYSICAL JOURNAL, 1993, 64 (02) : A109 - A109
  • [9] 4Pi microscopy deconvolution with a variable point-spread function
    Baddeley, David
    Carl, Christian
    Cremer, Christoph
    [J]. APPLIED OPTICS, 2006, 45 (27) : 7056 - 7064
  • [10] Sensitivity to point-spread function parameters in medical ultrasound image deconvolution
    Shin, Ho-Chul
    Prager, Richard
    Ng, James
    Gomersall, Henry
    Kingsbury, Nick
    Treece, Graham
    Gee, Andrew
    [J]. ULTRASONICS, 2009, 49 (03) : 344 - 357