PD Detection and Analysis of Oil-pressboard Insulation under Pulsed DC Voltage

被引:15
|
作者
Li, Junhao [1 ]
Zhang, Liang [1 ]
Han, Xutao [1 ]
Yao, Xiu [2 ]
Li, Yanming [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian, Peoples R China
[2] SUNY Buffalo, Dept Elect Engn, Buffalo, NY USA
关键词
Partial discharge; pulsating DC voltage; Converter transformer; Oil-pressboard insulation; PARTIAL DISCHARGE;
D O I
10.1109/TDEI.2016.005820
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
HVDC transmission has been adopted widely for its large energy transport capacity, high stability and more economical in long-distance power transmission. Converter transformer is the key equipment in HVDC transmission system. The insulation of converter transformer valve side endures a composite voltage including AC, DC and pulsating component etc. Partial discharge (PD) occurring in a void surrounded by insulating material is believed to be one of the main causes of insulation breakdown and it is the main factor of electrical aging of materials. Therefore, it is important to recognize the prebreakdown phenomena and to evaluate the lifetime of insulating materials. Much research has been carried out to study the partial discharge characteristics under pure AC or DC voltage. Only a few investigations were focused on composite voltage. In order to obtain more understanding of PD characteristics under composite voltage, the PD detection and analysis of oil-pressboard insulation under pulsating DC voltage waveform are studied in this paper. The voltage waveform of converter transformer is analyzed through computer simulation. A 6-pulse DC voltage generator and PD detection system are set up. Influence of the DC component and pulsating component to the PD characteristics is studied in lab test. The experimental results show the DC component and pulsating component affect the PD inception voltage, but the pulsating component has more significant influence to PD characteristics than DC component. The study provides an experimental foundation for the converter transformer insulation breakdown mechanism analysis.
引用
收藏
页码:324 / 330
页数:7
相关论文
共 50 条
  • [1] PD Characteristics of Oil-pressboard Insulation under AC and DC Mixed Voltage
    Li, Junhao
    Han, Xutao
    Liu, Zehui
    Yao, Xiu
    Li, Yanming
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (01) : 444 - 450
  • [2] Influence of moisture on the interface charge of oil-pressboard composite insulation under DC voltage
    Qi, Bo
    Jiao, Yanqiu
    Gao, Chunjia
    Zhang, Shuqi
    Zhao, Xiaolin
    Li, Chengrong
    [J]. HIGH VOLTAGE, 2018, 3 (01): : 73 - 77
  • [3] Polarity Characteristics of Accumulated Charge in Oil-pressboard Composite Insulation Under DC Voltage
    Zhuang, Yu
    Wang, Yonghong
    Wei, Xinlao
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (23): : 8791 - 8802
  • [4] Characteristics of oil-pressboard insulation under polarity reversal voltage
    Wang, Yonghong
    Wei, Xinlao
    Chen, Qingguo
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2012, 32 (19): : 161 - 168
  • [5] Effect of Cellulose Impurities on Partial Discharges in Oil-pressboard Insulation under DC Voltage
    Li, Yuan
    Zhang, Qiaogen
    Ding, Yuqin
    Zhao, Yi
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (04) : 2271 - 2273
  • [6] Flow Electrification Characteristics of Typical Plane Oil-Pressboard Insulation Under AC/DC Voltage
    Lin, Lin
    Chen, Qingguo
    Chi, Minghe
    Wei, Xinlao
    Zhu, Xuecheng
    Gao, Zhiwei
    [J]. 2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 80 - 83
  • [7] PD Classification in Oil-pressboard Insulation by Simulating a Needle-plate Model with plus DC Voltage
    Li, Simeng
    Li, Qingquan
    He, Dongxin
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2019, 26 (01) : 261 - 269
  • [8] Study on Development Characteristics of Partial Discharge in Oil-Pressboard Insulation under Constant DC Voltage
    Zhang, Chengjie
    Li, Yuan
    Yang, Senhong
    Li, Ranran
    [J]. ENERGIES, 2023, 16 (10)
  • [9] Interface Charge Polarity Effect Based Analysis Model for Electric Field in Oil-pressboard Insulation under DC Voltage
    Qi, Bo
    Gao, Chunjia
    Zhao, Xiaolin
    Li, Chengrong
    Wu, Hao
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (05) : 2704 - 2711
  • [10] Characteristics of Creeping Discharge Caused by a Needle Electrode in Oil-Pressboard Insulation under plus DC Voltage
    Li, Simeng
    Liu, Zhihua
    Ji, Shengchang
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2021, 28 (01) : 215 - 222