Analysis of Measurement Inaccuracy in Superlubricity Tests

被引:39
|
作者
Li, Jinjin [1 ]
Zhang, Chenhui [1 ]
Sun, Liang [1 ]
Luo, Jianbin [1 ]
机构
[1] Tsinghua Univ, State Key Lab Tribol, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Superlubricity; Friction Test Methods; Friction Coefficient; LOW-FRICTION; WEAR;
D O I
10.1080/10402004.2012.732200
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Although investigations on superlubricity are increasing, the corresponding measurement errors, which have a great effect on the measured friction coefficient, have not been widely discussed. The present article analyzes the origin of friction measurement errors in a rotating ball-on-flat apparatus and shows that these errors play an important role in the relationship between the measured and real friction coefficient. Based on the analysis, two methods were proposed to eliminate the main measurement error. One is obtaining the same friction coefficients in two reverse sliding directions by adjusting the level of the substrate (rotating plane) and the other is averaging the measured friction coefficients in two reverse sliding directions. The designed experiments proved the effectiveness of the two methods in eliminating the measurement error. Such methods are also effective for investigations on superlubricity.
引用
收藏
页码:141 / 147
页数:7
相关论文
共 50 条
  • [1] Measurement inaccuracy
    Kochsiek, M
    [J]. PTB-MITTEILUNGEN, 2001, 111 (03): : 208 - 209
  • [2] Uncertainty measurement with the kinematic telescopic bar during industrial robot inaccuracy tests
    Jozwik, Jerzy
    Jacniacka, Elzbieta
    Ostrowski, Dawid
    [J]. II INTERNATIONAL CONFERENCE OF COMPUTATIONAL METHODS IN ENGINEERING SCIENCE (CMES'17), 2017, 15
  • [3] INACCURACY IN RAINFALL MEASUREMENT
    MELLANBY, K
    [J]. NATURE, 1976, 264 (5582) : 167 - 167
  • [4] Measurement inaccuracy in air purification
    不详
    [J]. GEFAHRSTOFFE REINHALTUNG DER LUFT, 2006, 66 (10): : 397 - 397
  • [5] The public understanding of measurement inaccuracy
    Newton, PE
    [J]. BRITISH EDUCATIONAL RESEARCH JOURNAL, 2005, 31 (04) : 419 - 442
  • [6] INACCURACY OF THE DERIVED FIBRINOGEN MEASUREMENT
    CHITOLIE, A
    MACKIE, IJ
    GRANT, D
    HAMILTON, JL
    MACHIN, SM
    [J]. BLOOD COAGULATION & FIBRINOLYSIS, 1994, 5 (06) : 955 - 957
  • [7] The inaccuracy of the endoscopic anastomotic measurement techniques
    Tuma, Faiz
    Waheed, Abdul
    Khorgami, Zhamak
    Khaitan, Leena
    [J]. ANNALS OF LAPAROSCOPIC AND ENDOSCOPIC SURGERY, 2019, 4
  • [8] Analysis of inaccuracy in the measurement of the volume flow at different orifice double set of orifices
    Wroblewska, Elzbieta
    Synowiec, Piotr
    Wedrychowicz, Wieslaw
    Andruszkiewicz, Artur
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2018, 94 (08): : 154 - 157
  • [9] INACCURACY OF 4 CHEMICAL PROCEDURES AS DIAGNOSTIC TESTS FOR CANCER
    HENRY, RJ
    BERKMAN, S
    LITTLE, MS
    WINZLER, RJ
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1951, 147 (01): : 37 - 39
  • [10] Inaccuracy of routine creatinine measurement in canine urine
    Trumel, C
    Diquélou, A
    Lefebvre, H
    Braun, JP
    [J]. VETERINARY CLINICAL PATHOLOGY, 2004, 33 (03) : 128 - 132