Critical review of information relevant to the correction of the effect of chemical impurities in gases used for the realization of ITS-90 fixed points

被引:22
|
作者
Pavese, Franco [1 ]
机构
[1] Ist Nazl Ric Metrol INRIM, I-10135 Turin, Italy
关键词
TRIPLE-POINT; ISOTOPIC COMPOSITION; THERMODYNAMIC PROPERTIES; PHASE SEPARATION; ARGON; NEON; EQUILIBRIUM; MIXTURES; TEMPERATURE; DEUTERIUM;
D O I
10.1088/0026-1394/46/1/007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
According to the Guide to the Expression of Uncertainty in Measurement (GUM) on which the expression of uncertainty in the field of metrology is based, since 1995, 'it is assumed that the results of a measurement have been corrected for all recognised significant systematic effects'. Since the International Temperature Scale of 1990 specifies that the substances used for the realization of the 'fixed points' be 'ideally pure', to fully implement the intent of the GUM corrections should be applied for any chemical impurities that affect the value of the measurand. In general, thermometrists' opinion is that significant laboratory research and more literature search are still needed for further progress towards reliable corrections. This paper, reviewing the available literature data, shows that the situation is more favourable in the case of the substances used for the realization of the Scale reference points in the range 13.8 K to 273.16 K based on the use of hydrogen, neon, oxygen and argon. The appendix reports a similar review also for nitrogen. Then the paper discusses the other conditions, physical-chemical and thermal, of the substances inside the thermometric cells, concurring with the chemical impurity effects to the overall state of knowledge of the realized triple point temperature relevant to the solution of the problem of performing the corrections.
引用
收藏
页码:47 / 61
页数:15
相关论文
共 12 条
  • [1] Methods for the Realization of its-90 Fixed Points: Necessity of Improvement
    A. G. Ivanova
    S. F. Gerasimov
    A. I. Pokhodun
    V. М. Fuksov
    [J]. Measurement Techniques, 2021, 64 : 573 - 579
  • [2] Methods for the Realization of its-90 Fixed Points: Necessity of Improvement
    Ivanova, A. G.
    Gerasimov, S. F.
    Pokhodun, A., I
    Fuksov, V. M.
    [J]. MEASUREMENT TECHNIQUES, 2021, 64 (07) : 573 - 579
  • [3] Determination of the uncertainties for ITS-90 realization by SPRTs between fixed points
    Meyer, C. W.
    Ripple, D. C.
    [J]. METROLOGIA, 2006, 43 (05) : 327 - 340
  • [4] A criterion for uniformity of a temperature field in realization of the ITS-90 fixed points
    Ilin, AU
    [J]. TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 7, PTS 1 AND 2, 2003, 684 : 297 - 301
  • [5] Realization of Low-Temperature Fixed Points of the ITS-90 at NMIJ/AIST
    T. Nakano
    O. Tamura
    H. Sakurai
    [J]. International Journal of Thermophysics, 2007, 28 : 1893 - 1903
  • [6] Realization of low-temperature fixed points of the ITS-90 at NMIJ/AIST
    Nakano, T.
    Tamura, O.
    Sakurai, H.
    [J]. INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2007, 28 (06) : 1893 - 1903
  • [7] Realization of two temperature reference points between argon and mercury fixed points on ITS-90
    El-Shamma, H
    [J]. TEMPMEKO 2001: 8TH INTERNATIONAL SYMPOSIUM ON TEMPERATURE AND THERMAL MEASUREMENT IN INDUSTRY AND SCIENCE, VOL 1 & 2, PROCEEDINGS, 2002, : 435 - 440
  • [8] Realization at IMGC of the ITS-90 fixed points from the argon triple point upwards
    Marcarino, P
    Steur, PPM
    Dematteis, R
    [J]. TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 7, PTS 1 AND 2, 2003, 684 : 65 - 70
  • [9] Liquidus slopes of impurities in ITS-90 fixed points from the mercury point to the copper point in the low concentration limit
    Pearce, Jonathan V.
    Gisby, John A.
    Steur, Peter P. M.
    [J]. METROLOGIA, 2016, 53 (04) : 1101 - 1114
  • [10] Methods for the assessment of correction for chemical-impurity effects and related uncertainty in ITS-90 fixed points, namely of e-H2, Ne, O2 and Ar
    Pavese, Franco
    [J]. METROLOGIA, 2011, 48 (05) : 268 - 274