Influence of reference temperature on exergy and exergoeconomic performance of a natural gas fired thermal power plant

被引:10
|
作者
Anozie, Ambrose N. [1 ]
Odejobi, Oludare J. [1 ]
机构
[1] Obafemi Awolowo Univ, Dept Chem Engn, Appl Thermodynam & Proc Design Res Lab, Ife 220005, Nigeria
关键词
reference temperature; irreversibility; exergetic efficiency; exergy loss costs; exergoeconomic loss cost; exergy improvement potential; exergoeconomic improvement potential; ENERGY;
D O I
10.1504/IJEX.2013.055780
中图分类号
O414.1 [热力学];
学科分类号
摘要
The influence of reference temperature on exergy and exergoeconomic performance parameters of a thermal plant was investigated. The plant was simulated using HYSYS (2003) process simulator software and the exergy and exergoeconomic analyses were done using Microsoft EXCEL spreadsheet. As reference temperature increased from 15 degrees C to 35 degrees C, exergy efficiency decreased from 11.7% to 11.5% and irreversibility increased from 1790 MW to 1812 MW. Also, overall exergy cost decreased from 6650.78 MW to 6055.40 MW and monetary cost from $75,343.84/h to $68,430.19/h. The optimum (base case) reference temperature, where the exergy and the monetary exergy loss costs were at minimum, was found to be 30 degrees C. At this temperature both the condenser and boiler units made significant contributions to the process exergy and monetary exergy loss costs. The study concluded that the performance of the thermal plant depends on reference temperature, efficiencies of condenser and boiler units.
引用
收藏
页码:102 / 123
页数:22
相关论文
共 50 条
  • [1] Exergoeconomic and exergoenvironmental analysis of a coal-fired thermal power plant
    Duzcan, Abdullah
    Kara, Yusuf Ali
    [J]. JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2021, 43 (12)
  • [2] Exergoeconomic and exergoenvironmental analysis of a coal-fired thermal power plant
    Abdullah Duzcan
    Yusuf Ali Kara
    [J]. Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2021, 43
  • [3] Exergy analysis of operating lignite fired thermal power plant
    Ganapathy, T.
    Alagumurthi, N.
    Gakkhar, R.P.
    Murugesan, K.
    [J]. Journal of Engineering Science and Technology Review, 2009, 2 (01) : 123 - 130
  • [4] Energy and exergy analyses of partial repowering of a natural gas-fired steam power plant
    [J]. Ahmadi, Gholamreza (Gholamreza.ahmadi@iaukhsh.ac.ir), 1600, Inderscience Enterprises Ltd., 29, route de Pre-Bois, Case Postale 856, CH-1215 Geneva 15, CH-1215, Switzerland (23):
  • [5] Energy and Exergy Analyses of a Natural Gas Fired Combined Cycle Power Plant: Parametric Study
    Kilic, Ahmed Emin
    Arcaklioglu, Erol
    [J]. JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2023, 26 (02): : 721 - 730
  • [6] Energy and exergy analyses of partial repowering of a natural gas-fired steam power plant
    Ahmadi, Gholamreza
    Akbari, Omid Ali
    Zarringhalam, Majid
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2017, 23 (02) : 149 - 168
  • [7] Combined Cycle and Steam Gas-Fired Power Plant Analysis through Exergoeconomic and Extended Combined Pinch and Exergy Methods
    Manesh, M. H. Khoshgoftar
    Rosen, M. A.
    [J]. JOURNAL OF ENERGY ENGINEERING, 2018, 144 (02)
  • [8] Exergy, exergoeconomic and exergy-based emission cost analyses of a coconut husk-fired power and desalination plant
    Lourenco, Atilio Barbosa
    Carvalho, Monica
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2020, 32 (03) : 267 - 291
  • [9] Thermal performance of gas turbine power plant based on exergy analysis
    Ibrahim, Thamir K.
    Basrawi, Firdaus
    Awad, Omar I.
    Abdullah, Ahmed N.
    Najafi, G.
    Mamat, Rizlman
    Hagos, F. Y.
    [J]. APPLIED THERMAL ENGINEERING, 2017, 115 : 977 - 985