Analytical calibration of linear transducer arrays for photoacoustic tomography

被引:1
|
作者
Oeri, Milan [1 ]
Bost, Wolfgang [1 ]
Fournelle, Marc [1 ]
机构
[1] Fraunhofer IBMT, Dept Biomed Ultrasound Res, D-66386 St Ingbert, Germany
关键词
photoacoustics; ultrasound; linear transducer calibration; tomography; 3-DIMENSIONAL ULTRASOUND; RECONSTRUCTION; SYSTEM;
D O I
10.1117/12.2182567
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tomographic photoacoustic imaging (PAT) allows to overcome the anisotropic image resolution of conventional reflection mode imaging. In order to achieve high-resolution, tomographic images, precise information on the position of each detector element is required. PAT systems that acquire signals from rotating linear transducer arrays come with inevitable transducer misalignments. Up to now, transducer orientation (x/y-tilt) and radial distance uncertainty were measured experimentally or have not been considered. Uncalibrated, these systems suffer from characteristic artifacts yielding misinterpretations of anatomic structures. Herein, we derive the artifact mathematically and investigate an analytical calibration method that enables the calculation and compensation of important transducer positioning parameters: the rotational radius and in-plane tilt. We studied the approach theoretically and evaluated the performance of the developed algorithm both on numerical and experimental data. A PAT system based on a 5-MHz linear transducer array, a multichannel electronics platform with channel data access, a NIR-emitting laser system and a rotating samples is used to demonstrate the benefit of the transducer calibration method providing isotropic resolution of 160 mu m.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Photoacoustic tomography based on a novel linear array ultrasound transducer configuration
    Lin, Xiangwei
    Leng, Guanji
    Shen, Yi
    Wang, Yan
    Zhang, Miao
    Sun, Mingjian
    [J]. 2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 399 - 403
  • [2] Multi-transducer photoacoustic tomography imaging without radius calibration using Deep learning
    Rajendran, Praveenbalaji
    Pramanik, Manojit
    [J]. PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2022, 2022, 11960
  • [3] A Study of reconstruction in photoacoustic tomography with a focused transducer
    Li, Meng-Lin
    Wang, Lihong V.
    [J]. PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2007, 2007, 6437
  • [4] Deep-learning-based multi-transducer photoacoustic tomography imaging without radius calibration
    Rajendran, Praveenbalaji
    Pramanik, Manojit
    [J]. OPTICS LETTERS, 2021, 46 (18) : 4510 - 4513
  • [5] Photoacoustic and ultrasonic coimage with a linear transducer array
    Zeng, YG
    Xing, D
    Wang, Y
    Yin, BZ
    Chen, Q
    [J]. OPTICS LETTERS, 2004, 29 (15) : 1760 - 1762
  • [6] Compressed sensing in synthetic aperture photoacoustic tomography based on a linear-array ultrasound transducer
    蔺祥伟
    冯乃章
    屈亚威
    陈德应
    沈毅
    孙明健
    [J]. Chinese Optics Letters, 2017, 15 (10) : 55 - 59
  • [7] Compressed sensing in synthetic aperture photoacoustic tomography based on a linear-array ultrasound transducer
    Lin, Xiangwei
    Feng, Naizhang
    Qu, Yawei
    Chen, Deying
    Shen, Yi
    Sun, Mingjian
    [J]. CHINESE OPTICS LETTERS, 2017, 15 (10)
  • [8] A generative adversarial network for artifact removal in photoacoustic computed tomography with a linear-array transducer
    Vu, Tri
    Li, Mucong
    Humayun, Hannah
    Zhou, Yuan
    Yao, Junjie
    [J]. EXPERIMENTAL BIOLOGY AND MEDICINE, 2020, 245 (07) : 597 - 605
  • [9] Breast Transmission Ultrasound Tomography Based on Capacitive Micromachined Ultrasonic Transducer Linear Arrays
    Pei, Yu
    Zhang, Yu
    Hu, Shumin
    Wang, Zhihao
    Li, Yifan
    He, Changde
    Zhang, Sai
    Wang, Renxin
    Zhang, Wendong
    Zhang, Guojun
    [J]. IEEE SENSORS JOURNAL, 2022, 22 (02) : 1209 - 1217
  • [10] Effects of size and arrangement of virtual transducer on photoacoustic tomography
    王少华
    陶超
    刘晓峻
    [J]. Chinese Physics B, 2013, 22 (07) : 278 - 283