Augmentation of vessel squeezing at coronary-myocardial bridge by nitroglycerin: Study by quantitative coronary angiography and intravascular ultrasound

被引:74
|
作者
Hongo, Y [1 ]
Tada, H [1 ]
Ito, K [1 ]
Yasumura, Y [1 ]
Miyatake, K [1 ]
Yamagishi, M [1 ]
机构
[1] Natl Cardiovasc Ctr, Cardiol Div Med, Suita, Osaka 565, Japan
关键词
D O I
10.1016/S0002-8703(99)70123-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Nitroglycerin is known to augment vessel wall squeezing ai the site with coronary-myocardial bridging (CMB). This study was designed td define the mechanism of nitroglycerin-induced augmentation of CMB in clinical settings. Methods We analyzed nitroglycerin reactivity at the site with CMB in 39 patients. Maximal and minimal diameters of CMB during a cardiac cycle were measured by quantitative angiography before and after intracoronary administration of 250 mu g nitroglycerin. In 15 patients, CMB sites were observed by intravascular ultrasound to determine the intimal thickness and the time-serial change in vessel area. Results Before nitroglycerin, CMB was demonstrated with angiography in 25 patients, and the remaining 14 patients showed CMB after nitroglycerin. The maximal diameter during diastole increased from 1.4 +/- 0.4 mm to 1.9 +/- 0.4 mm after nitroglycerin, whereas the minimal diameter during systole decreased from 1.0 +/- 0.4 mm to 0.7 +/- 0.4 mm (P <.01). Thus nitroglycerin augmented the percent vessel narrowing during systole from 24% +/- 21% to 65% +/- 16% (P <.01). Under these conditions, intravascular ultrasound showed the reduction of the cross-sectional area of the sites with CMB by -38% +/- 16% (P <.01) during systole, and this phenomenon continued to early diastole (-30% +/- 16%). The intimal thickness was 0.32 +/- 0.10 mm, which suggests the absence of atherosclerotic disease at CMB sites. Conclusions These results indicate that nitroglycerin-induced augmentation of the percent narrowing of CMB can be derived from further systolic compression of the vessel lumen as well as diastolic expansion, probably because of the increase in vessel compliance after nitroglycerin. We suggest that the delayed dilation of coronary lumen during the early diastole may contribute to the occurrence of myocardial ischemia.
引用
收藏
页码:345 / 350
页数:6
相关论文
共 50 条
  • [1] Intravascular ultrasound and quantitative coronary angiography
    Takahashi, T
    Honda, Y
    Russo, RJ
    Fitzgerald, PJ
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 55 (01) : 118 - 128
  • [2] Coronary angiography and intravascular ultrasound
    Nissen, S
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (4A): : 15A - 20A
  • [3] CORONARY PLAQUE BURDEN BY QUANTITATIVE CORONARY ANGIOGRAPHY CORRELATES WITH PLAQUE BURDEN BY CT CORONARY ANGIOGRAPHY AND INTRAVASCULAR ULTRASOUND
    Kalynych, Anna M.
    Vazquez, Gustavo
    Karmpaliotis, Dimitri
    Qian, Zhen
    Krivitsky, Eric
    Marvasty, Idean B.
    Rinehart, Sarah
    Voros, Szilard
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [4] Use of Intravascular Ultrasound and Coronary Angiography to Measure the Prevalence of Myocardial Bridge in Heart Transplant Patients
    Medina, Frank
    Estrada, Andy
    Fernandez, Christopher
    Balkhy, Husam
    Kim, Gene
    Shah, Atman
    Nathan, Sandeep
    Paul, Jonathan
    Kalathiya, Rohan
    Blair, John
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2023, 205 : 176 - 181
  • [5] Anatomical sex differences in coronary arteries assessed by quantitative coronary angiography and intravascular ultrasound
    Musumeci, G
    Petronio, AS
    Baglini, R
    Limbruno, U
    De Luca, L
    Mariani, M
    Merelli, A
    [J]. EUROPEAN HEART JOURNAL, 2001, 22 : 204 - 204
  • [6] Comparison of coronary vessel sizing using coronary angiography versus intravascular ultrasound in Egyptian patients
    Ebaid, Hany h
    El-sehili, Ahmed
    Rasheed, Hisham
    Ammar, Hisham
    Mahrous, Mohamed
    [J]. CARDIOMETRY, 2021, (20): : 184 - 189
  • [7] Comparison of intravascular ultrasound and quantitative coronary angiography for the assessment of coronary artery disease progression
    Berry, Colin
    L'Allier, Philippe L.
    Gregoire, Jean
    Lesperance, Jacques
    Levesque, Sylvie
    Ibrahim, Reda
    Tardif, Jean-Claude
    [J]. CIRCULATION, 2007, 115 (14) : 1851 - 1857
  • [8] Intravascular ultrasound in equivocal coronary angiography
    Gaster, AL
    Thayssen, P
    Mathar, R
    [J]. SCANDINAVIAN CARDIOVASCULAR JOURNAL, 1999, 33 (05) : 315 - 318
  • [9] Intravascular ultrasound imaging in recurrent myocardial ischaemia and unremarkable coronary angiography
    Scheffold, N
    Schongart, H
    Kaag, N
    Eisenlohr, E
    Cyran, J
    [J]. DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1998, 123 (18) : 556 - 561
  • [10] Comparison of Small Blood Vessel Diameter with Intravascular Ultrasound and Coronary Angiography for Guidance of Percutaneous Coronary Intervention
    Zuniga-Mendoza, Sergio A.
    Zayas-Diaz, Emanuel
    Armenta-Velazquez, Victoria R.
    Silva-Baeza, Ana A.
    Beltran-Ochoa, Juan J.
    Medina-Servin, Misael A.
    Zavala-Cerna, Maria G.
    [J]. DIAGNOSTICS, 2024, 14 (12)