The impact of oral appliance therapy with moderate mandibular advancement on obstructive sleep apnea and upper airway volume

被引:17
|
作者
Pahkala, Riitta [1 ]
Seppa, J. [2 ]
Myllykangas, R. [3 ]
Tervaniemi, J. [4 ]
Vartiainen, V. M. [4 ]
Suominen, A. L. [1 ,5 ]
Muraja-Murro, A. [6 ]
机构
[1] Kuopio Univ Hosp, Dept Oral & Maxillofacial Dis, POB 100, Kuopio 70029, Finland
[2] Kuopio Univ Hosp, Head & Neck Ctr, Kuopio, Finland
[3] Univ Eastern Finland, Inst Dent, Dept Med, Fac Hlth Sci, Kuopio, Finland
[4] Univ Eastern Finland, Dept Clin Radiol, Kuopio Univ Hosp, Inst Dent Oral & Maxillofacial Radiol, Kuopio, Finland
[5] Univ Eastern Finland, Inst Dent, Dept Oral Publ Hlth, Kuopio, Finland
[6] Kuopio Univ Hosp, Dept Clin Neurophysiol, Diagnost Imaging Ctr, Kuopio, Finland
关键词
Obstructive sleep apnea; Mandibular advancement device; Apnea-hypopnea index; CBCT; Upper airway volume; QUALITY-OF-LIFE; NASAL OBSTRUCTION; RESISTANCE; POSITION; RISK;
D O I
10.1007/s11325-019-01914-3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose To find out if a moderate protrusion with a mandibular advancement device (MAD) can significantly increase the upper airway volume and, further, what signs and symptoms of obstructive sleep apnea (OSA) can be improved by this maneuver. Methods There were 58 adults diagnosed with OSA who were referred for MAD therapy. The mean apnea-hypopnea index (AHI) was 19.2 (SD 8.6). Five indicators of signs and symptoms of OSA (AHI, oxygen saturation, snoring, daytime sleepiness, and health-related quality of life) were evaluated at the baseline and after 6 months of MAD therapy. Nasal resistance and airway volume and cross-sectional areas with and without the MAD in situ were recorded. Based on AHI reduction, the treatment response was classified as complete, partial, or non-complete. Statistical analyses included the chi-square,ttests, Mann-Whitney U tests, and regression analyses (linear and logistic). Results Twenty-three patients attained a complete response (residual AHI< 5 events/h) to MAD therapy. In 13 subjects, the response was partial, and in 9 patients, it was non-complete. The complete responders were significantly younger, and they had a deeper overbite than partial/non-complete responders. A convex profile associated positively, but a vertically restricted throat and increased lower facial height associated negatively with the increase in airway volume. Conclusions Excellent MAD therapy outcomes were achieved in most patients. Only age and deep bite had some influence on AHI reduction, indicating multifactorial nature in the response to MAD therapy.
引用
收藏
页码:865 / 873
页数:9
相关论文
共 50 条
  • [1] The impact of oral appliance therapy with moderate mandibular advancement on obstructive sleep apnea and upper airway volume
    Riitta Pahkala
    J. Seppä
    R. Myllykangas
    J. Tervaniemi
    V. M. Vartiainen
    A. L. Suominen
    A. Muraja-Murro
    [J]. Sleep and Breathing, 2020, 24 : 865 - 873
  • [2] Minimizing the mandibular advancement in an oral appliance for the treatment of obstructive sleep apnea
    Anitua, Eduardo
    Duran-Cantolla, Joaquin
    Zamora Almeida, Gabriela
    Hamdan Alkhraisat, Mohammad
    [J]. SLEEP MEDICINE, 2017, 34 : 226 - 231
  • [3] Effect of oral appliance therapy on upper airway collapsibility in obstructive sleep apnea
    Ng, AT
    Gotsopoulos, H
    Qian, J
    Cistulli, PA
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2003, 168 (02) : 238 - 241
  • [4] Functional contribution of a mandibular advancement oral appliance to upper airway patency in obstructive sleep apnoea
    Tsuiki, S.
    Ryan, C.
    Lowe, A. A.
    Inoue, Y.
    [J]. JOURNAL OF SLEEP RESEARCH, 2006, 15 : 203 - 203
  • [5] Oral appliance therapy for obstructive sleep apnea syndrome: Progressive mandibular advancement during polysomnography
    Raphaelson, MA
    Alpher, EJ
    Bakker, KW
    Perlstrom, JR
    [J]. CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE, 1998, 16 (01): : 44 - 50
  • [6] Mandibular Advancement Appliance for Obstructive Sleep Apnea Treatment
    Kostrzewa-Janicka, J.
    Sliwinski, P.
    Wojda, M.
    Rolski, D.
    Mierzwinska-Nastalska, E.
    [J]. RESPIRATORY TREATMENT AND PREVENTION, 2017, 944 : 63 - 71
  • [7] Effect of a Mandibular Advancement Device on the Upper Airway in a Patient With Obstructive Sleep Apnea
    Ignacio Flores-Orozco, Elan
    Esthela Tiznado-Orozco, Gaby
    Diaz-Pena, Rogelio
    Flores Orozco, Esteban Isai
    Galletti, Cosimo
    Gazia, Francesco
    Galletti, Francesco
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2020, 31 (01) : E32 - E35
  • [8] Functional effects of mandibular advancement oral appliances on awake upper airway patency in obstructive sleep apnea
    Tsuiki, S.
    Ryan, F.
    Alan, L.
    Inoue, Y.
    [J]. SLEEP, 2007, 30 : A172 - A172
  • [9] Changes in Upper Airway Volume in Edentulous Obstructive Sleep Apnea Patients Treated with Modified Mandibular Advancement Device
    Tripathi, Arvind
    Gupta, Ashutosh
    Sarkar, Sabyasachi
    Tripathi, Suryakant
    Gupta, Narendra
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (06): : 453 - 458
  • [10] The effect of gradually increased mandibular advancement on the efficacy of an oral appliance in the treatment of obstructive sleep apnea
    Ma, Yanyan
    Yu, Min
    Gao, Xuemei
    [J]. JOURNAL OF CLINICAL SLEEP MEDICINE, 2020, 16 (08): : 1369 - 1376