Dosimetric Comparison of Four Different Techniques for Supraclavicular Irradiation in 3D-conformal Radiotherapy of Breast Cancer

被引:6
|
作者
Firouzjah, Razzagh Abedi [1 ]
Banaei, Amin [2 ,3 ]
Farhood, Bagher [4 ]
Bakhshandeh, Mohsen [5 ]
机构
[1] Shahid Sadoughi Univ Med Sci, Fac Med, Dept Med Phys, Yazd, Iran
[2] AJA Univ Med Sci, Fac Paramed Sci, Dept Radiol, Tehran, Iran
[3] Tarbiat Modares Univ, Fac Med Sci, Dept Med Phys, Tehran, Iran
[4] Kashan Univ Med Sci, Fac Paramed Sci, Dept Med Phys & Radiol, Kashan, Iran
[5] Shahid Beheshti Univ Med Sci, Allied Med Sci Fac, Radiat Technol Dept, Tehran 1985717443, Iran
来源
HEALTH PHYSICS | 2019年 / 116卷 / 05期
关键词
accelerators; medical; cancer; dose; radiation therapy; RADIATION-THERAPY; HEAD; MASTECTOMY; ALGORITHMS; STENOSIS; PHANTOM; IMRT;
D O I
10.1097/HP.0000000000000991
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study aimed to compare and evaluated the dosimetric characteristics of esophagus, spinal cord, carotid artery, lungs, and brachial plexus in patients with breast cancer undergoing four various techniques of supraclavicular irradiation. By keeping unchanged the breast tangential radiotherapy fields, four different treatment field arrangements were created to irradiate the supraclavicular region as follows: (1) four field (4F; 1 anterior-posterior and 1 posterior-anterior), (2) six field (6F; 2 anterior-posterior and 2 posterior-anterior), (3) five field-1 (5F-1; 2 anterior-posterior and 1 posterior-anterior), and (4) five field-2 (5F-2; 1 anterior-posterior and 2 posterior-anterior). Then, the dosimetric parameters for the above-mentioned organs were evaluated. The mean dose (D-mean) of the esophagus had significant difference between 6F and 5F-2 techniques. For the spinal cord, the D-mean dosimetric parameter demonstrated significant difference between the 4F and 6F techniques, and between the 4F and 5F-1 techniques, with lower values for the 4F technique. There was no significant difference between the different irradiation techniques in all the dosimetric parameters for the carotid artery. The D-mean of the left lung significantly differed between the 4F and 5F-2 techniques, with lower values for the 5F-2 technique. Furthermore, the V-20Gy dosimetric parameter had significant difference between the 4F and 6F, and also 4F and 5F-2, techniques with lower values for 5F-2. The maximum dose (D-max) of the brachial plexus showed significant difference between the two techniques of 5F. The V-45Gy dosimetric parameter of the brachial plexus revealed significant difference between the 4F and 6F techniques, and also between the 4F and 5F-1 techniques, with lower values for 5F-1. In general, these techniques had similar dosimetric results, with little differences. The dosimetric parameters for the esophagus and lung showed better results with the 5F-2 technique in comparison with other techniques. Dosimetric results for the brachial plexus and spinal cord improved with the 5F-1 and 4F techniques, respectively, against other techniques. Dose distribution for the carotid artery did not differ in the four irradiation techniques.
引用
收藏
页码:631 / 636
页数:6
相关论文
共 50 条
  • [1] Dosimetric comparison of conventional and conformal techniques in the irradiation of the supraclavicular fossa in breast cancer
    Ahmed, M.
    [J]. EUROPEAN JOURNAL OF CANCER, 2014, 50 : S210 - S210
  • [2] COMPARISON OF HYBRID TECHNIQUES WITH 3D-CONFORMAL RADIOTHERAPY IN PATIENTS WITH LUNG CANCER
    Azaklioglu, Oemer
    Akcay, Dogukan
    Er, Ilhami
    Akguengoer, Kadir
    Demiral, Ayse Nur
    [J]. JOURNAL OF BASIC AND CLINICAL HEALTH SCIENCES, 2023, 7 (03): : 50 - 57
  • [3] Dosimetric comparison of radiation techniques in the irradiation of the supraclavicular fossa in breast cancer
    Ahmed, M.
    King, D.
    Barron, S.
    Quigley, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S64 - S65
  • [4] Hypofractionated Helical Tomotherapy for breast cancer Vs prone 3D-conformal radiotherapy: A dosimetric analysis
    Giugliano, F.
    Iadanza, L.
    Falivene, S.
    Borzillo, V.
    Cammarota, F.
    Muto, M.
    Ravo, V.
    Di Franco, R.
    Muto, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S52 - S52
  • [5] Dosimetric impact of axillary irradiation: Comparison between 3D-conformal radiotherapy and two types of intensity-modulated radiotherapy
    Abbassi, Louisa Marie
    Arsene-Henry, Alexandre
    Kirova, Youlia M.
    [J]. CANCER RESEARCH, 2020, 80 (04)
  • [6] Dosimetric comparison of four different radiotherapy planning techniques for adjuvant radiotherapy of left-sided breast, axilla, and supraclavicular fossa
    Gupte, Ajinkya
    Sasidharan, Ajay
    Kunheri, Beena
    Kumar, Amala
    Reddy, Sruthi
    Nair, Haridas
    Pushpaja, K. U.
    Anoop, R.
    Dutta, Debnarayan
    [J]. JOURNAL OF MEDICAL PHYSICS, 2021, 46 (04) : 308 - 314
  • [7] Dosimetric comparison between 3D-conformal radiation therapy and VMAT in Total Lymphoid Irradiation
    Ferrer, C.
    Huertas, C.
    Escribano, A.
    Plaza, R.
    Morera, R.
    Serrada, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S852 - S852
  • [8] Feasibility of TomoDirect 3D-conformal Radiotherapy for Craniospinal Irradiation
    Kim, J.
    Jeong, K.
    Chung, Y.
    Choi, W.
    Woo, J.
    Baek, J.
    Bak, J.
    Cho, J.
    Cho, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S828 - S828
  • [9] Dosimetric comparison of radiotherapy techniques for left breast, axilla and supraclavicular fossa
    Gupte, A.
    Sasidharan, A.
    Kunheri, B.
    Kumar, A.
    Reddy, S.
    Nair, H.
    Dutta, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1366 - S1366
  • [10] Comparison of Breast Radiotherapy Induced Secondary Cancer Risk for 3D-Conformal Therapy, IMRT and VMAT
    Lee, B.
    Sung, J.
    Yoon, M.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)