Improved Electric Wiring of Hemoglobin with Impure-Multiwalled Carbon Nanotube/Nafion Modified Glassy Carbon Electrode and Its Highly Selective Hydrogen Peroxide Biosensing

被引:77
|
作者
Kumar, Annamalai Senthil [1 ]
Gayathri, Prakasam [1 ]
Barathi, Palani [1 ]
Vijayaraghavan, Rajagopalan [2 ]
机构
[1] Vellore Inst Technol Univ, Sch Adv Sci, Environm & Analyt Chem Div, Vellore 632014, Tamil Nadu, India
[2] Vellore Inst Technol Univ, Sch Adv Sci, Mat Chem Div, Vellore 632014, Tamil Nadu, India
来源
JOURNAL OF PHYSICAL CHEMISTRY C | 2012年 / 116卷 / 44期
关键词
CHEMICALLY-MODIFIED ELECTRODE; DIRECT ELECTROCHEMISTRY; NANOGRAPHITE IMPURITIES; AMPEROMETRIC DETERMINATION; IONIC LIQUID; NITRIC-OXIDE; ELECTROCATALYSIS; NANOPARTICLES; OXIDATION; REDUCTION;
D O I
10.1021/jp3064933
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A hemoglobin (Hb) modified glassy carbon electrode consisting of low cost as commercially received impure-multiwalled carbon nanotube (i-MWCNT, 90% purity) and rafion (GCE/i-MWCNT@Hb/Nf) has been demonstrated for improved electric wiring of Fib and efficient direct electrontransfer characteristics. This report is the first attempt for coupling i-MWCNT with Hb for the biosensor purpose. The Hb electrode was assembled by a simple preparation procedure within 38.3 (+/- 2.5) min of time, without any linker, surfactant, promoters, and extensive functionalization of the MWCNT. Impurities within the i-MWCNT such as metal oxides (Fe3O4, Co3O4, and NiO), graphite, and amorphous carbon were quantitatively identified by X-ray diffraction (XRD) and thermogravimetric analysis (TGA). The metal oxide impurities were found to assist the binding of Hb onto i-MWCNT, whereas the graphitic impurity facilitated the direct electron-transfer reaction. The measured surface excess value of the Fib on the GCE/CNT@Hb/Nf with respect to different CNTs are in the sequences of i-MWCNT > purified-MWCNT > impure single-walled carbon nanotube > functionalized-MWCNT. The GCE/i-MWCNT@Hb/Nf shows enhanced and selective H2O2 electrocatalytic reduction signal without interference from cysteine, ascorbic acid, uric acid, nitrite, and nitrate. Note that Hb can mediate the nitrite reduction reaction too; however, no interference has been observed in this work. Various types of milk, cosmetic bleaching cream, and medical real samples were successfully analyzed with recovery values closer to 100%. The electrode has been found to be stable for 110 days.
引用
收藏
页码:23692 / 23703
页数:12
相关论文
共 50 条
  • [1] Analytical Biosensing of Hydrogen Peroxide on Brilliant Cresyl Blue/Multiwalled Carbon Nanotubes Modified Glassy Carbon Electrode
    Peng, Ya-Yu
    Upadhyay, A. K.
    Chen, Shen-Ming
    [J]. ELECTROANALYSIS, 2010, 22 (04) : 463 - 470
  • [2] Analytical sensing of hydrogen peroxide on Ag nanoparticles–multiwalled carbon nanotube-modified glassy carbon electrode
    Ahmadreza Afraz
    Amir Abbas Rafati
    Ali Hajian
    [J]. Journal of Solid State Electrochemistry, 2013, 17 : 2017 - 2025
  • [3] Direct electrochemistry of hemoglobin/peptide-carbon nanotube modified electrode for hydrogen peroxide biosensing
    Sheikholeslam, Mohammadali
    Nanda, Piyush
    Sanati, Alireza
    Pritzker, Mark
    Chen, P.
    [J]. MATERIALS LETTERS, 2023, 335
  • [4] Analytical sensing of hydrogen peroxide on Ag nanoparticles-multiwalled carbon nanotube-modified glassy carbon electrode
    Afraz, Ahmadreza
    Rafati, Amir Abbas
    Hajian, Ali
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2013, 17 (07) : 2017 - 2025
  • [5] Direct electrochemistry and biosensing of hydrogen peroxide of horseradish peroxidase immobilized at multiwalled carbon nanotube/alumina-coated silica nanocomposite modified glassy carbon electrode
    Huang, Jian-Lung
    Tsai, Yu-Chen
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2009, 140 (01): : 267 - 272
  • [6] A thionine functionalized multiwalled carbon nanotube modified electrode for the determination of hydrogen peroxide
    Jeykumari, D. R. Shobha
    Ramaprabhu, S.
    Narayanan, S. Sriman
    [J]. CARBON, 2007, 45 (06) : 1340 - 1353
  • [7] Iron(III) oxide adsorbed multiwalled carbon nanotube modified glassy carbon electrode as a precursor for enhanced Prussian blue formation and selective hydrogen peroxide sensing
    Shanmugam, Ranganathan
    Barathi, Palani
    Kumar, Annamalai Senthil
    [J]. COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2014, 452 : 129 - 137
  • [8] NOVEL HYDROGEN PEROXIDE SENSOR USING A MULTIWALLED CARBON NANOTUBE-COBALAMIN NANOCOMPOSITE GLASSY CARBON ELECTRODE
    Liu, Suqin
    Dai, Gaopeng
    Luo, Tianxiong
    Wang, Jingwen
    [J]. INSTRUMENTATION SCIENCE & TECHNOLOGY, 2015, 43 (06) : 649 - 660
  • [9] An amperometric hydrogen peroxide biosensor based on Co3O4 nanoparticles and multiwalled carbon nanotube modified glassy carbon electrode
    Kacar, Ceren
    Dalkiran, Berna
    Erden, Pinar Esra
    Kilic, Esma
    [J]. APPLIED SURFACE SCIENCE, 2014, 311 : 139 - 146
  • [10] A hydrogen peroxide biosensor with high stability based on gelatin-multiwalled carbon nanotubes modified glassy carbon electrode
    Yulin Wang
    Tianyu Li
    Weijie Zhang
    Yaqin Huang
    [J]. Journal of Solid State Electrochemistry, 2014, 18 : 1981 - 1987