Amperometric biosensor based on horseradish peroxidase-immobilised magnetic microparticles

被引:35
|
作者
Yu, DH
Blankert, B
Bodoki, E
Bollo, S
Viré, JC
Sandulescu, R
Nomura, A
Kauffmann, JM
机构
[1] Univ Libre Bruxelles, Inst Pharmaceut, B-1050 Brussels, Belgium
[2] Univ Med Farm, Juliu Hatieganu, Cluj Napoca, Romania
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2006年 / 113卷 / 02期
关键词
D O I
10.1016/j.snb.2005.07.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Magnetised silica-based microparticles (MMPs) (5 mu m) with a high density of nanopores were used for horseradish peroxidase (HRP) immobilization and amperometric biosensor development in batch conditions. The resulting biosensor was applied to study the peroxidation of clozapine (CLZ) which is a dibenzoazepine drug often used in the treatment of neurological disorders. The amperometric response corresponded to the electroreduction of CLZ-oxidized products namely a nitrenium cation and quinoneimine derivative of CLZ. Despite a relatively low amount of immobilized HR-P (0.3 mu mol/g), clozapine quantification in the micromolar concentration range was achieved by the use of a magnetized solid paraffin carbon paste electrode for microparticles attraction. Diffusion of substrate and products of the enzyme reaction within the nanopores were identified as limiting factors in the biosensor response. This amperometric biosensor configuration has number of interesting advantages such as ease and reproducible microparticle layer renewing, low enzyme consumption, controlled surface immobilization, protective enzyme microenvironment etc. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:749 / 754
页数:6
相关论文
共 50 条
  • [1] Amperometric biosensor for polyphenol based on horseradish peroxidase immobilized on gold electrodes
    Imabayashi, S
    Kong, YT
    Watanabe, M
    [J]. ELECTROANALYSIS, 2001, 13 (05) : 408 - 412
  • [2] An Amperometric Horseradish Peroxidase Inhibition Biosensor for the Determination of Phenylhydrazine
    Zhou-Sheng Yang
    Wei-Li Wu
    Xi Chen
    Yun-Chun Liu
    [J]. Analytical Sciences, 2008, 24 : 895 - 899
  • [3] An amperometric horseradish peroxidase inhibition biosensor for the determination of phenylhydrazine
    Yang, Zhou-Sheng
    Wu, Wei-Li
    Chen, Xi
    Liu, Yun-Chun
    [J]. ANALYTICAL SCIENCES, 2008, 24 (07) : 895 - 899
  • [4] An amperometric hydrogen peroxide biosensor based on immobilization of horseradish peroxidase on an electrode modified with magnetic dextran microspheres
    Hai-Li Zhang
    Guo-Song Lai
    De-Yan Han
    Ai-Min Yu
    [J]. Analytical and Bioanalytical Chemistry, 2008, 390 : 971 - 977
  • [5] An amperometric hydrogen peroxide biosensor based on immobilization of horseradish peroxidase on an electrode modified with magnetic dextran microspheres
    Zhang, Hai-Li
    Lai, Guo-Song
    Han, De-Yan
    Yu, Ai-Min
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (03) : 971 - 977
  • [6] Amperometric biosensor based on horseradish peroxidase for biogenic amine determinations in biological samples
    Castilho, TJ
    Sotomayor, MDT
    Kubota, LT
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (04) : 785 - 791
  • [7] Amperometric determination of cadmium, lead, and mercury metal ions using a novel polymer immobilised horseradish peroxidase biosensor system
    Silwana, Bongiwe
    Van Der Horst, Charlton
    Iwuoha, Emmanuel
    Somerset, Vernon
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2014, 49 (13): : 1501 - 1511
  • [8] Chemically glycosylation improves the stability of an amperometric horseradish peroxidase biosensor
    Hernandez-Cancel, Griselle
    Suazo-Davila, Damaris
    Medina-Guzman, Johnsue
    Rosado-Gonzalez, Maria
    Diaz-Vazquez, Liz M.
    Griebenow, Kai
    [J]. ANALYTICA CHIMICA ACTA, 2015, 854 : 129 - 139
  • [9] Amperometric inhibitive biosensor based on horseradish peroxidase-nanoporous gold for sulfide determination
    Sun, Huihui
    Liu, Zhuang
    Wu, Chao
    Xu, Ping
    Wang, Xia
    [J]. SCIENTIFIC REPORTS, 2016, 6
  • [10] Hydrogen peroxide sensitive amperometric biosensor based on horseradish peroxidase entrapped in a polypyrrole electrode
    Razola, SS
    Ruiz, BL
    Diez, NM
    Mark, HB
    Kauffmann, JM
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12): : 921 - 928