Compartmental analysis of washout effect in rat brain: in-beam OpenPET measurement using a 11C beam

被引:18
|
作者
Hirano, Yoshiyuki [1 ]
Kinouchi, Shoko [1 ,2 ]
Ikoma, Yoko [1 ]
Yoshida, Eiji [1 ]
Wakizaka, Hidekazu [1 ]
Ito, Hiroshi [1 ]
Yamaya, Taiga [1 ]
机构
[1] Natl Inst Radiol Sci, Mol Imaging Ctr, Inage Ku, Chiba 2638555, Japan
[2] Chiba Univ, Inage Ku, Chiba 2638522, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2013年 / 58卷 / 23期
关键词
POSITRON-EMISSION-TOMOGRAPHY; CEREBRAL-BLOOD-FLOW; RANGE VERIFICATION; PET; PROTON; THERAPY; MODEL; IMPLEMENTATION; IRRADIATION; DELIVERY;
D O I
10.1088/0031-9155/58/23/8281
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In-beam positron emission tomography (PET) is expected to enable visualization of a dose verification using positron emitters (beta+ decay). For accurate dose verification, correction of the washout of the positron emitters should be made. In addition, the quantitative washout rate has a potential usefulness as a diagnostic index, but modeling for this has not been studied yet. In this paper, therefore, we applied compartment analyses to in-beam PET data acquired by our small OpenPET prototype, which has a physically opened field-of-view (FOV) between two detector rings. A rat brain was located at the FOV and was irradiated by a C-11 beam. Time activity curves of the irradiated field were measured immediately after the irradiations, and the washout rate was obtained based on two models: the two-washout model (medium decay, k(2m); slow decay, k(2s)) developed in a study of rabbit irradiation; and the two-compartment model used in nuclear medicine, where efflux from tissue to blood (k(2)), influx (k(3)) and efflux (k(4)) from the first to second compartments in tissue were evaluated. The observed k(2m) and k(2s) were 0.34 and 0.005 min(-1), respectively, which was consistent with the rabbit study. Also k(2m) was close to the washout rate in cerebral blood flow (CBF) measurements by dynamic PET with O-15-water, while, k(2), k(3), and k(4) were 0.16, 0.15 and 0.007 min(-1). Our present work suggested the dynamics of C-11 might be relevant to CBF or permeability of a molecule containing C-11 atoms might be regulated by a transporter because the k(2) was relatively low compared with a simple diffusion tracer.
引用
收藏
页码:8281 / 8294
页数:14
相关论文
共 50 条
  • [1] Washout rate in rat brain irradiated by a 11C beam after acetazolamide loading using a small single-ring OpenPET prototype
    Hirano, Yoshiyuki
    Takuwa, Hiroyuki
    Yoshida, Eiji
    Nishikido, Fumihiko
    Nakajima, Yasunori
    Wakizaka, Hidekatsu
    Yamaya, Taiga
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (05): : 1875 - 1887
  • [2] Washout effect in rats during in-beam imaging by the small OpenPET prototype
    Yamaya, Taiga
    Yoshida, Eiji
    Kinouchi, Shoko
    Wakizaka, Hidekatsu
    Tsuji, Atsushi
    Tashima, Hideaki
    Nishikido, Fumihiko
    Nakajima, Yasunori
    Sato, Shinji
    Inaniwa, Taku
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [3] Monte Carlo simulation of small OpenPET prototype with 11C beam irradiation: effects of secondary particles on in-beam imaging
    Hirano, Yoshiyuki
    Yoshida, Eiji
    Kinouchi, Shoko
    Nishikido, Fumihiko
    Inadma, Naoko
    Murayama, Hideo
    Yamaya, Taiga
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (07): : 1623 - 1640
  • [4] Biological washout modelling for in-beam PET: rabbit brain irradiation by 11C and 15O ion beams
    Toramatsu, Chie
    Mohammadi, Akram
    Wakizaka, Hidekazu
    Seki, Chie
    Nishikido, Fumihiko
    Sato, Shinji
    Kanno, Iwao
    Takahashi, Miwako
    Karasawa, Kumiko
    Hirano, Yoshiyuki
    Yamaya, Taiga
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (10):
  • [5] In-Beam PET Measurements of Washout in Rabbit Using 10C, 11C and 15O Ion Beams
    Toramatsu, Chie
    Yoshida, Eiji
    Wakizaka, Hidekazu
    Mohammadi, Akram
    Tashima, Hideaki
    Nishikido, Fumihiko
    Kitagawa, Atsuchi
    Inaniwa, Taku
    Karasawa, Kumiko
    Yamaya, Taiga
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3250 - 3251
  • [6] Washout effect in rabbit brain: in-beam PET measurements using C-10, C-11 and O-15 ion beams
    Toramatsu, Chie
    Yoshida, Eiji
    Wakizaka, Hidekazu
    Mohammadi, Akram
    Ikoma, Yoko
    Tashima, Hideaki
    Nishikido, Fumihiko
    Kitagawa, Atsushi
    Karasawa, Kumiko
    Hirano, Yoshiyuki
    Yamaya, Taiga
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (03):
  • [7] Study of In-Vivo Kinetics of Induced Particles :In-Beam PET Measurement of Washout in Rabbits Using 150 Ion Beam
    Toramatsu, C.
    Wakizaka, H.
    Mohammadi, A.
    Nitta, M.
    Iwao, Y.
    Nishikido, F.
    Tashima, H.
    Yoshida, E.
    Kitagawa, A.
    Karasawa, K.
    Yamaya, T.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E510 - E510
  • [8] Compartmental analysis of [11C]temozolomide in gliomas and normal brain tissue
    Hinz, R.
    Saleem, A.
    Brock, C. S.
    Matthews, J. C.
    Jones, T.
    Price, P. M.
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2009, 29 : S346 - S346
  • [9] Range verification of radioactive ion beams of 11C and 15O using in-beam PET imaging
    Mohammadi, Akram
    Tashima, Hideaki
    Iwao, Yuma
    Takyu, Sodai
    Akamatsu, Go
    Nishikido, Furnihiko
    Yoshida, Eiji
    Kitagawa, Atsushi
    Parodi, Katia
    Yamaya, Taiga
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (14):
  • [10] Influence of momentum acceptance on range monitoring of 11C and 15O ion beams using in-beam PET
    Mohammadi, Akram
    Tashima, Hideaki
    Iwao, Yuma
    Takyu, Sodai
    Akamatsu, Go
    Kang, Han Gyu
    Nishikido, Fumihiko
    Yoshida, Eiji
    Chacon, Andrew
    Safavi-Naeini, Mitra
    Parodi, Katia
    Yamaya, Taiga
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (12):