How Do CAD Models Compare With Reverse Engineered Manufactured Components for Use in Wear Analysis?

被引:17
|
作者
Teeter, Matthew G. [1 ,2 ]
Naudie, Douglas D. R. [1 ,3 ]
Bourne, Robert B. [2 ,3 ]
Holdsworth, David W. [1 ,2 ,3 ]
机构
[1] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] Univ Western Ontario, Div Orthopaed Surg, London, ON, Canada
基金
加拿大健康研究院;
关键词
TIBIAL POST WEAR; KNEE REPLACEMENTS; BACKSIDE WEAR; TOMOGRAPHY; PRECISION; RADIATION; ACCURACY; RSA;
D O I
10.1007/s11999-011-2143-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To accurately quantify polyethylene wear in retrieved arthroplasty components, the original geometry of the component must be estimated accurately using a reference geometry such as a computer-aided design (CAD) model or a never-implanted insert. However, differences may exist between the CAD model and manufactured inserts resulting from manufacturing tolerances. We quantified the deviations between CAD models and newly manufactured inserts and determined how these deviations compared with using a never-implanted insert as a reference geometry. We obtained five cruciate-retaining (CR) and five posterior-stabilizing (PS) tibial inserts and their CAD models. The inserts were scanned and reconstructed using microcomputed tomography (micro-CT). Differences in volume and surface geometry were measured among (1) the individual inserts; (2) between the inserts and a CAD model; and (3) between the inserts and a reference geometry constructed from multiple scanned inserts averaged together. The micro-CT volumes were, on average, 0.4% smaller (34-178 mm(3)) than the CAD model volumes. The mean deviation between the CAD model and insert surface geometry was 25.7 mu m smaller for CR and 36.8 mu m smaller for PS. The mean deviation between the inserts and an averaged reference geometry was 1.4 mu m larger for CR and 0.4 mu m smaller for PS. Deviations exist between manufactured tibial inserts and CAD models that could cause errors in wear measurements. Scanned inserts may better represent the preimplantation geometry of worn inserts than CAD models, depending on the manufacturing variability between lots. The magnitude of the error in estimation of the preimplantation geometry of a retrieved component could add or subtract the equivalent of 1 year of wear.
引用
收藏
页码:1847 / 1854
页数:8
相关论文
共 50 条
  • [1] CAD-driven analysis and beautification of reverse engineered geometric models
    Gauthier, Silvere
    Subsol, Gerard
    Beniere, Roseline
    Puech, William
    [J]. INTERNATIONAL JOURNAL OF INTERACTIVE DESIGN AND MANUFACTURING - IJIDEM, 2020, 14 (04): : 1211 - 1226
  • [2] CAD-driven analysis and beautification of reverse engineered geometric models
    Silvére Gauthier
    Gérard Subsol
    Roseline Bénière
    William Puech
    [J]. International Journal on Interactive Design and Manufacturing (IJIDeM), 2020, 14 : 1211 - 1226
  • [3] Manufacturability of reverse engineered CAD-models: a case study
    Kruth, JP
    Kerstens, A
    Dejonghe, IP
    [J]. MACHINING IMPOSSIBLE SHAPES, 1999, 18 : 187 - 195
  • [4] CAD-driven Pattern Recognition in Reverse Engineered Models
    Gauthier, S.
    Puech, W.
    Beniere, R.
    Subsol, G.
    [J]. PROCEEDINGS OF THE 14TH INTERNATIONAL JOINT CONFERENCE ON COMPUTER VISION, IMAGING AND COMPUTER GRAPHICS THEORY AND APPLICATIONS (GRAPP), VOL 1, 2019, : 244 - 254
  • [5] Variations in the use of curative surgery: How do regions in the US compare
    J. B. O'Connell
    M. A. Maggard
    C. Y. Ko
    [J]. Annals of Surgical Oncology, 2004, 11 : S124 - S124
  • [6] Variations in the use of curative surgery: How do regions in the US compare
    O'Connell, JB
    Maggard, MA
    Ko, CY
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2004, 11 (02) : S124 - S124
  • [7] Developing geometric analysis tools to compare heat map results for metal additive manufactured components
    Urbanic, R. Jill
    Mohajernia, Bita
    Nazemi, Navid
    [J]. Computer-Aided Design and Applications, 2020, 17 (02) : 288 - 311
  • [8] Single-Use Flexible Ureteroscopes: How Do They Compare with Reusable Ureteroscopes?
    Scotland, Kymora B.
    Chan, Justin Y. H.
    Chew, Ben H.
    [J]. JOURNAL OF ENDOUROLOGY, 2019, 33 (02) : 71 - 78
  • [9] How do leaf and ecosystem measures of water-use efficiency compare?
    Medlyn, Belinda E.
    De Kauwe, Martin G.
    Lin, Yan-Shih
    Knauer, Jurgen
    Duursma, Remko A.
    Williams, Christopher A.
    Arneth, Almut
    Clement, Rob
    Isaac, Peter
    Limousin, Jean-Marc
    Linderson, Maj-Lena
    Meir, Patrick
    Martin-StPaul, Nicolas
    Wingate, Lisa
    [J]. NEW PHYTOLOGIST, 2017, 216 (03) : 758 - 770
  • [10] Simultaneous registration of multiple range views for use in reverse engineering of CAD models
    Eggert, DW
    Fitzgibbon, AW
    Fisher, RB
    [J]. COMPUTER VISION AND IMAGE UNDERSTANDING, 1998, 69 (03) : 253 - 272