Clinical Interpretation Standards and Quality Assurance for the Multicenter PET/CT Trial Rubidium-ARMI

被引:31
|
作者
Renaud, Jennifer M. [1 ]
Mylonas, Ilias [1 ]
McArdle, Brian [1 ]
Dowsley, Taylor [1 ]
Yip, Kathy [2 ]
Turcotte, Eric [3 ]
Guimond, Jean [4 ]
Trottier, Mikael [4 ]
Pibarot, Philipe [4 ]
Maguire, Conor [5 ]
Lalonde, Lucille [5 ]
Gulenchyn, Karen [6 ]
Wisenberg, Gerald [7 ]
Wells, R. Glenn [1 ]
Ruddy, Terrence [1 ]
Chow, Benjamin [1 ]
Beanlands, Rob S. B. [1 ]
deKemp, Robert A. [1 ]
机构
[1] Univ Ottawa, Inst Heart, Ottawa, ON K1Y 4W7, Canada
[2] KMH Cardiol & Diagnost Ctr, Mississauga, ON, Canada
[3] Univ Sherbrooke, Ctr Hosp, Sherbrooke, PQ J1K 2R1, Canada
[4] Inst Univ Cardiol & Pneumol Quebec, Quebec City, PQ, Canada
[5] Univ Alberta Hosp, Edmonton, AB T6G 2B7, Canada
[6] St Josephs Healthcare, Hamilton, ON, Canada
[7] St Josephs Hlth Care, London, ON, Canada
来源
JOURNAL OF NUCLEAR MEDICINE | 2014年 / 55卷 / 01期
关键词
positron emission tomography; myocardial perfusion imaging; Rb-82; POSITRON-EMISSION-TOMOGRAPHY; MYOCARDIAL BLOOD-FLOW; CORONARY-ARTERY-DISEASE; COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; MAGNETIC-RESONANCE; RB-82; PET; SPECT; QUANTIFICATION; GENERATOR;
D O I
10.2967/jnumed.112.117515
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rubidium-ARMI (Rb-82 as an Alternative Radiopharmaceutical for Myocardial Imaging) is a multicenter trial to evaluate the accuracy, outcomes, and cost-effectiveness of low-dose Rb-82 perfusion imaging using 3-dimensional (3D) PET/CT technology. Standardized imaging protocols are essential to ensure consistent interpretation. Methods: Cardiac phantom qualifying scans were obtained at 7 recruiting centers. Low-dose (10 MBq/kg) rest and pharmacologic stress Rb-82 PET scans were obtained in 25 patients at each site. Summed stress scores, summed rest scores, and summed difference scores (SSS, SRS, and SDS [respectively] = SSS-SRS) were evaluated using 17-segment visual interpretation with a discretized color map. All scans were coread at the core lab (University of Ottawa Heart Institute) to assess agreement of scoring, clinical diagnosis, and image quality. Scoring differences greater than 3 underwent a third review to improve consensus. Scoring agreement was evaluated with intraclass correlation coefficient (ICC-r), concordance of clinical interpretation, and image quality using kappa coefficient and percentage agreement. Patient Tc-99m and (TI)-T-201 SPECT scans (n = 25) from 2 centers were analyzed similarly for comparison to Rb-82. Results: Qualifying scores of SSS = 2, SDS = 2, were achieved uniformly at all imaging sites on 9 different 3D PET/CT scanners. Patient scores showed good agreement between core and recruiting sites: ICC-r = 0.92, 0.77 for SSS, SDS. Eighty-five and eighty-seven percent of SSS and SDS scores, respectively, had site-core differences of 3 or less. After consensus review, scoring agreement improved to ICC-r = 5 0.97, 0.96 for SSS, SDS (P, 0.05). The agreement of normal versus abnormal (SSS >= 4) and nonischemic versus ischemic (SDS >= 2) studies was excellent: ICC-r = 0.90 and 0.88. Overall interpretation showed excellent agreement, with a kappa = 0.94. Image quality was perceived differently by the site versus core reviewers (90% vs. 76% good or better; P<0.05). By comparison, scoring agreement of the SPECT scans was ICC-r = 0.82, 0.72 for SSS, SDS. Seventy-six and eighty-eight percent of SSS and SDS scores, respectively, had site-core differences of 3 or less. Consensus review again improved scoring agreement to ICC-r = 0.97, 0.90 for SSS, SDS (P<0.05). Conclusion: 82Rb myocardial perfusion imaging protocols were implemented with highly repeatable interpretation in centers using 3D PET/CT technology, through an effective standardization and quality assurance program. Site scoring of 82Rb PET myocardial perfusion imaging scans was found to be in good agreement with core lab standards, suggesting that the data from these centers may be combined for analysis of the rubidium-ARMI endpoints.
引用
收藏
页码:58 / 64
页数:7
相关论文
共 50 条
  • [1] Imaging standards and quality assurance for the PET Rubidium ARMI (Alternative Radiopharmaceutical for Myocardial Imaging) multicentre trial
    Renaud, Jennifer
    Mylonas, Ilias
    Ziadi, Maria
    Youssef, George
    Nasser, Daniel
    Cliche, Jean-Pierre
    Yip, Kathy
    Beanlands, Rob
    deKemp, Robert
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [2] PET IMAGING STANDARDS AND QUALITY ASSURANCE FOR THE RUBIDIUM ARMI (ALTERNATIVE RADIOPHARMACEUTICAL FOR MYOCARDIAL IMAGING) MULTICENTRE TRIAL
    Renaud, J. M.
    Mylonas, I.
    Youssef, G.
    Nasser, D.
    Cliche, J.
    Yip, K.
    Lavallee, E.
    Turcotte, E.
    Guimond, J.
    Pibarot, P.
    Wandzilak, G.
    Maguire, C.
    Lalonde, L.
    Madison, S.
    Marriott, C.
    Gulenchyn, K.
    Beanlands, R. S.
    deKemp, R. A.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2011, 27 (05) : S270 - S270
  • [3] Low-dose 3D PET rubidium ARMI (Alternative Radiopharmaceutical for Myocardial Imaging) multicentre trial standards and quality assurance
    Renaud, Jennifer
    Mylonas, Ilias
    Yip, Kathy
    Turcotte, Eric
    Pibarot, Philippe
    Maguire, Conor
    Gulenchyn, Karen
    Wisenberg, Gerald
    Beanlands, Rob
    deKemp, Robert
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [5] Quantitative quality assurance in a multicenter HARDI clinical trial at 3 T
    Zhou, Xiaopeng
    Sakaie, Ken E.
    Debbins, Josef P.
    Kirsch, John E.
    Tatsuoka, Curtis
    Fox, Robert J.
    Lowe, Mark J.
    [J]. MAGNETIC RESONANCE IMAGING, 2017, 35 : 81 - 90
  • [6] Quality assurance for quantitative MRI in a multicenter trial
    Van Houdt, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S240 - S241
  • [7] Quality assurance and validation for Quantitative PET in Multicenter Trials
    Lubberink, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S241 - S241
  • [8] PET CT workshop - Accreditation and quality assurance
    Kemp, B.
    Mawlawi, O.
    Esser, P.
    Anderson, J.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2633 - 2633
  • [9] Guidelines for quality control of PET/CT scans in a multicenter clinical study
    Hristova, Ivalina
    Boellaard, Ronald
    Galette, Paul
    Shankar, Lalitha K.
    Liu, Yan
    Stroobants, Sigrid
    Hoekstra, Otto S.
    Oyen, Wim J. G.
    [J]. EJNMMI PHYSICS, 2017, 4
  • [10] Guidelines for quality control of PET/CT scans in a multicenter clinical study
    Ivalina Hristova
    Ronald Boellaard
    Paul Galette
    Lalitha K. Shankar
    Yan Liu
    Sigrid Stroobants
    Otto S. Hoekstra
    Wim J.G. Oyen
    [J]. EJNMMI Physics, 4