Doses to organs and tissues from concomitant imaging in radiotherapy: a suggested framework for clinical justification

被引:10
|
作者
Harrison, R. M. [1 ]
机构
[1] Newcastle Gen Hosp, Dept Reg Med Phys, Newcastle Upon Tyne NE4 6BE, Tyne & Wear, England
来源
BRITISH JOURNAL OF RADIOLOGY | 2008年 / 81卷 / 972期
关键词
D O I
10.1259/bjr/77088613
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The increasing use of imaging for localization and verification in radiotherapy has raised issues concerning the justifiable doses to critical organs and tissues from concomitant exposures, particularly when extensive image-guided radiotherapy is indicated. Doses at positions remote from the target volume include components from high-energy leakage and scatter, as well as from concomitant imaging. In this paper, simulated prostate, breast and larynx treatments are used to compare doses from both high-energy and concomitant exposures as a function of distance from the target volume. It is suggested that the fraction, R, of the total dose at any point within the patient that is attributable to concomitant exposures may be a useful aid in their justification. R is small within the target volume and at large distances from it. However, there is a critical region immediately adjacent to the planning target volume where the dose from concomitant imaging combines with leakage and scatter to give values of R that approach 0.5 in the examples given here. This is noteworthy because the regions just outside the target volume will receive total doses in the order of 1 Gy, where commensurately high risk factors may not be substantially reduced because of cell kill. Other studies have identified these regions as sites of second cancers. The justification of an imaging regimen might therefore usefully take into account the maximum value of R encountered from the combination of imaging and radiotherapy for particular treatment sites. (C) 2008 The British Institute of Radiology
引用
收藏
页码:970 / 974
页数:5
相关论文
共 45 条
  • [1] Doses to critical organs following radiotherapy and concomitant imaging of the larynx and breast
    Harrison, R. M.
    Wilkinson, M.
    Rawlings, D. J.
    Moore, M.
    BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (960): : 989 - 995
  • [2] A SUGGESTED FRAMEWORK FOR CLINICAL JUSTIFICATION OF IGRT
    Harrison, R.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S31 - S31
  • [3] Justification and optimisation of radiation doses for imaging in radiotherapy
    Torresin, A.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S165 - S166
  • [4] On effective dose for radiotherapy based on doses to nontarget organs and tissues
    Uselmann, Adam J.
    Thomadsen, Bruce R.
    MEDICAL PHYSICS, 2015, 42 (02) : 977 - 982
  • [5] Doses to critical organs following radiotherapy and concomitant imaging of the larynx and breast (vol 80, pg 989, 2007)
    Harrison, R. M.
    Wilkinson, M.
    Rawlings, D. J.
    Moore, M.
    BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (962): : 164 - 164
  • [6] Second cancers following radiotherapy: a suggested common dosimetry framework for therapeutic and concomitant exposures
    Harrison, RM
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (924): : 986 - 990
  • [7] Organ doses from prostate radiotherapy and associated concomitant exposures
    Harrison, RM
    Wilkinson, M
    Shemilt, A
    Rawlings, DJ
    Moore, M
    Lecomber, AR
    BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (942): : 487 - 496
  • [8] Imaging practices and radiation doses from imaging in radiotherapy
    Siiskonen, Teemu
    Kaijaluoto, Sampsa
    Florea, Tudor
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 42 : 247 - 252
  • [9] Doses to organs and tissues from radon and its decay products
    Kendall, Gerry M.
    Smith, T.J.
    Journal of Radiological Protection, 2002, 22 (04) : 389 - 406
  • [10] DOSES TO ORGANS FROM CLINICAL APPLICATIONS OF RADIOIODINES
    ELLIS, RE