Designs and Concept Reliance of a Fully Automated High-Content Screening Platform

被引:7
|
作者
Radu, Constantin
Adrar, Hosna Sana
Alamir, Ab [2 ]
Hatherley, Ian [2 ]
Trung Trinh [2 ]
Djaballah, Hakim [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, HTS Core Facil, New York, NY 10065 USA
[2] Thermo Fisher Sci, Burlington, ON, Canada
来源
JALA | 2012年 / 17卷 / 05期
关键词
HCS; HTS; automation; IN Cell Analyzer 3000; IN Cell Analyzer 2000; ASSAY; HCS;
D O I
10.1177/2211068212453311
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High-content screening (HCS) is becoming an accepted platform in academic and industry screening labs and does require slightly different logistics for execution. To automate our stand-alone HCS microscopes, namely, an alpha IN Cell Analyzer 3000 (INCA3000), originally a Praelux unit hooked to a Hudson Plate Crane with a maximum capacity of 50 plates per run, and the IN Cell Analyzer 2000 (INCA2000), in which up to 320 plates could be fed per run using the Thermo Fisher Scientific Orbitor, we opted for a 4 m linear track system harboring both microscopes, plate washer, bulk dispensers, and a high-capacity incubator allowing us to perform both live and fixed cell-based assays while accessing both microscopes on deck. Considerations in design were given to the integration of the alpha INCA3000, a new gripper concept to access the onboard nest, and peripheral locations on deck to ensure a self-reliant system capable of achieving higher throughput. The resulting system, referred to as Hestia, has been fully operational since the new year, has an onboard capacity of 504 plates, and harbors the only fully automated alpha INCA3000 unit in the world.
引用
收藏
页码:359 / 369
页数:11
相关论文
共 50 条
  • [1] An automated high-content screening and assay platform for the analysis of spheroids at subcellular resolution
    Mysior, Margaritha M.
    Simpson, Jeremy C.
    PLOS ONE, 2024, 19 (11):
  • [2] Robotic device for fully automated high-content screening on C. elegans as a novel NAMs platform for DART assessment
    Mouchiroud, L.
    Katsyuba, E.
    Bourgeois, M.
    Stojkovic, L.
    Sanchez, H. Alvarez
    Tache, F.
    Cornaglia, M.
    TOXICOLOGY LETTERS, 2024, 399 : S121 - S121
  • [3] A fast, fully automated cell segmentation algorithm for high-throughput and high-content screening
    Fenistein, D.
    Lenseigne, B.
    Christophe, T.
    Brodin, P.
    Genovesio, A.
    CYTOMETRY PART A, 2008, 73A (10) : 958 - 964
  • [4] Automated microscopy for high-content RNAi screening
    Conrad, Christian
    Gerlich, Daniel W.
    JOURNAL OF CELL BIOLOGY, 2010, 188 (04): : 453 - 461
  • [5] Automated multiparametric platform for high-content and high-throughput analytical screening on living cells
    Geisler, T
    Ressler, J
    Harz, H
    Wolf, B
    Uhl, R
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2006, 3 (02) : 169 - 176
  • [6] Robotic device for fully automated high-content screening on the nematodeC. elegans as a novel NAMs platform for early toxicity assessment
    Mouchiroud, L.
    Katsyuba, E.
    Stojkovic, L.
    Bourgeois, M.
    Tache, F.
    Cornaglia, M.
    TOXICOLOGY LETTERS, 2023, 384 : S250 - S250
  • [7] Automated Image Analysis for High-Content Screening and Analysis
    Shariff, Aabid
    Kangas, Joshua
    Coelho, Luis Pedro
    Quinn, Shannon
    Murphy, Robert F.
    JOURNAL OF BIOMOLECULAR SCREENING, 2010, 15 (07) : 726 - 734
  • [8] Challenges and solutions to developing an automated high-throughput/high-content screening platform for the 'neglected' schistosome parasite
    Caffrey, Conor
    Chen, Steven
    Suzuki, Brian
    Singh, Rahul
    Arkin, Michelle
    FASEB JOURNAL, 2016, 30
  • [9] Challenges and solutions to developing an automated high-throughput/high-content screening platform for the 'neglected' schistosome parasite
    Caffrey, Conor
    Chen, Steven
    Suzuki, Brian
    Singh, Rahul
    Arkin, Michelle
    FASEB JOURNAL, 2016, 30
  • [10] High-content biology: Solutions for fully automated imaging and data generation
    Herrenknecht, K
    CYTOMETRY PART A, 2006, 69A (01) : 50 - 50