High level gamma radiation effects on Cernox™ cryogenic temperature sensors

被引:4
|
作者
Courts, S. S. [1 ]
机构
[1] Lake Shore Cryotron Inc, 575 McCorkle Blvd, Westerville, OH 43082 USA
来源
关键词
D O I
10.1088/1757-899X/278/1/012076
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Cryogenic temperature sensors are used in high energy particle colliders to monitor the temperatures of superconducting magnets, superconducting RF cavities, and cryogen infrastructure. While not intentional, these components are irradiated by leakage radiation during operation of the collider. A common type of cryogenic thermometer used in these applications is the Cernox (TM) resistance thermometer (CxRT) manufactured by Lake Shore Cryotronics, Inc. This work examines the radiation-induced calibration offsets on CxRT models CX-1050-SD-HT and CX-1080-SD-HT resulting from exposure to very high levels of gamma radiation. Samples from two different wafers of each of the two models tested were subjected to a gamma radiation dose ranging from 10 kGy to 5 MGy. Data were analysed in terms of the temperature-equivalent resistance change between pre- and post-irradiation calibrations. The data show that the resistance of these devices decreased following irradiation resulting in positive temperature offsets across the 1.4 K to 330 K temperature range. Variations in response were observed between wafers of the same CxRT model. Overall, the offsets increased with increasing temperature and increasing gamma radiation dose. At 1.8 K, the average offset increased from 0 mK to +13 mK as total dose increased from 10 kGy to 5 MGy. At 4.2 K, the average offset increased from +4 mK to +33 mK as total dose increased from 10 kGy to 5 MGy. Equivalent temperature offset data are presented over the 1.4 K to 330 K temperature range by CxRT model, wafer, and total gamma dose.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Radiation effects on cryogenic temperature sensors of Cernox, CGR and PtCo
    Tominaka, T
    Okuno, H
    Ohnishi, J
    Fukunishi, N
    Ryuto, H
    Ohtake, M
    Ikegami, K
    Goto, A
    Yano, Y
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2004, 14 (02) : 1802 - 1805
  • [2] High level gamma radiation effects on platinum and silicon diode cryogenic temperature sensors
    Courts, S. S.
    ADVANCES IN CRYOGENIC ENGINEERING, 2020, 755
  • [3] CRYOGENIC PRESSURE TEMPERATURE AND LEVEL TEMPERATURE SENSORS
    JUANARENA, DB
    RAO, MG
    CRYOGENICS, 1992, 32 (01) : 39 - 43
  • [4] A standardized Cernox™ cryogenic temperature sensor for aerospace applications
    Courts, Samuel Scott
    CRYOGENICS, 2014, 64 : 248 - 254
  • [5] Effects of cryogenic irradiation on temperature sensors
    Courts, SS
    Holmes, DS
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 41, PTS A AND B, 1996, : 1707 - 1714
  • [6] Effects of high intensity cryogenic irradiation and magnetic field on temperature sensors
    Filippov, YP
    Golikov, VV
    Kulagin, EN
    Shabratov, VG
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 43 PTS A AND B, 1998, 43 : 773 - 780
  • [7] 60Co gamma radiation effects on NPN transistor at cryogenic temperature
    Muddubasavanna, Darshan
    Anjum, Arshiya
    Nagaraj, Pushpa
    Patel, Gnana Prakash A.
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (11-12) : 1183 - 1188
  • [8] Irradiation of cryogenic temperature sensors by gamma dose of 1 MGy
    Filippov, Yu. P.
    Miklayev, V. M.
    Sukhanova, A. K.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (04):
  • [9] One year stability of Cernox™ and DT-670-SD silicon diode cryogenic temperature sensors operated at 77 K
    Courts, S.
    CRYOGENICS, 2020, 107 (107)
  • [10] CRYOGENIC TEMPERATURE SENSORS
    SWARTZ, JM
    SWARTZ, DL
    INSTRUMENTATION TECHNOLOGY, 1974, 21 (01): : 33 - 38