PERFORMANCE IMPROVEMENTS IN COMMERCIAL HEAT PUMP WATER HEATERS USING CARBON DIOXIDE

被引:0
|
作者
Bowers, C. D. [1 ]
Elbel, S. [1 ]
Petersen, M. [1 ]
Hrnjak, P. S. [2 ]
机构
[1] Creat Thermal Solut, 2209 N Willow Rd, Urbana, IL 61802 USA
[2] Univ Illinois, Urbana, IL 61801 USA
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Although heat pump water heaters are today widely accepted in Japan, where energy costs are high and government incentives for their use exist, acceptance of such a product in the U.S. has been slow. This trend is slowly changing with the introduction of heat pump water heaters into the residential market, but remains in the commercial sector. Barriers to heat pump water heater acceptance in the commercial market have historically been performance, reliability and first/operating costs. The use of carbon dioxide (R744) as the refrigerant in such a system can improve performance for relatively small increase in initial cost and make this technology more appealing. What makes R744 an excellent candidate for use in heat pump water heaters is not only the wide range of ambient temperatures within which it can operate, but also the excellent ability to match water to refrigerant temperatures on the high side, resulting in very high exit water temperatures of up to 82 degrees C (180 degrees F), as required by sanitary codes in the U.S.(Food Code, 2005), in a single pass, temperatures that are much more difficult to reach with other refrigerants. This can be especially attractive in applications where this water is used for the purpose of sanitation. While reliability has also been of concern historically, dramatic improvements have been made over the last several years through research done in the automotive industry and commercialization of R744 technology in residential water heating mainly in Japan. This paper presents the performance results from the development of an R744 commercial heat pump water heater of approximately 35kW and a comparison to a baseline R134a unit of the same capacity and footprint. In addition, recommendations are made for further improvements of the R744 system which could result in possible energy savings of up to 20%.
引用
收藏
页码:544 / +
页数:2
相关论文
共 50 条
  • [1] Theoretical performance analysis of heat pump water heaters using carbon dioxide as refrigerant
    Laipradit, Pramote
    Tiansuwan, Jirawan
    Kiatsiriroat, Tanongkiat
    Aye, Lu
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (04) : 356 - 366
  • [2] COMMERCIAL HEAT PUMP WATER HEATERS.
    Kohloss, Frederick H.
    Plumbing engineer, 1987, 15 (06): : 26 - 29
  • [3] Applications tests of commercial heat pump water heaters
    Oshinski, John N.
    Abrams, Donald W.
    Energy Engineering: Journal of the Association of Energy Engineering, 1988, 85 (06): : 49 - 71
  • [4] Seasonal performance rating of heat pump water heaters
    Morrison, GL
    Anderson, T
    Behnia, M
    SOLAR ENERGY, 2004, 76 (1-3) : 147 - 152
  • [5] Heat pump water heaters
    Zogg, R
    Dieckmann, J
    Roth, K
    Brodrick, J
    ASHRAE JOURNAL, 2005, 47 (03) : 98 - 99
  • [6] Transcritical carbon dioxide microchannel heat pump water heaters: Part II - System simulation and optimization
    Goodman, Christopher
    Fronk, Brian M.
    Garimella, Srinivas
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (04): : 870 - 880
  • [7] Performance of commercially available solar and heat pump water heaters
    Lloyd, C. R.
    Kerr, A. S. D.
    ENERGY POLICY, 2008, 36 (10) : 3807 - 3813
  • [8] STUDY ON PERFORMANCE OF HEAT PUMP WATER HEATERS IN SOUTH AFRICA
    Zhang, M.
    Huan, Z.
    2013 PROCEEDINGS OF THE 21ST DOMESTIC USE OF ENERGY CONFERENCE (DUE), 2013, : 119 - 124
  • [9] Development of high-efficiency carbon dioxide commercial heat pump water heater
    Petersen, Michael
    Bowers, Chad
    Elbel, Stefan
    Hrnjak, Pega
    HVAC&R RESEARCH, 2013, 19 (07): : 823 - 835
  • [10] Performance Assessment of Zeotropic Mixtures for Heat Pump Water Heaters
    Zhang, Nuochen
    Dai, Yuande
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2022, 36 (01) : 207 - 214