Liquid-liquid extraction in a rotating disc column: Solution of 2D population balance with HMMC

被引:10
|
作者
Buffo, A. [1 ]
Jama, M. [1 ]
Alopaeus, V. [1 ]
机构
[1] Aalto Univ, Sch Chem Technol, Dept Biotechnol & Chem Technol, Kemistintie 1, Espoo 02150, Finland
来源
基金
芬兰科学院;
关键词
Population balance; High-order moment-conserving method of classes (HMMC); Bivariate; Liquid-liquid extraction; Mass transfer; MOMENT-CONSERVING METHOD; NONIDEAL STIRRED-TANK; MASS-TRANSFER MODELS; QUADRATURE METHOD; DROP BREAKAGE; SIMULATION; EQUATIONS; AGGREGATION; SIZE; CFD;
D O I
10.1016/j.cherd.2016.09.002
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this work mass transfer in liquid-liquid extraction is investigated with the two-dimensional high-order moment-conserving method of classes (2D-HMMC) (Buffo and Alopaeus, 2016). The solution of a realistic liquid-liquid test case, a counter-current rotating disc column (RDC) composed of three stages where the droplets exchange mass with the continuous phase, is studied. This detailed modelling approach is compared with two other possible approximated models. In the first all the droplets are assumed to have the same size and concentration, and in the second all the droplets are assumed to have the same concentration but different sizes. The results of this comparison show that the information regarding the two-dimensional droplet size-concentration distribution may be needed to properly evaluate the mass transfer rates and therefore the behaviour of the system for all the operating conditions investigated. (C) 2016 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:270 / 281
页数:12
相关论文
共 50 条
  • [1] Flow around a rotating disc of a liquid-liquid extraction column
    Lameche, Mohammed
    Noureddine, Abdelkader
    UPB Scientific Bulletin, Series D: Mechanical Engineering, 2019, 81 (02): : 219 - 230
  • [2] LIQUID-LIQUID EXTRACTION IN A ROTATING DISC CONTRACTOR
    VERMIJS, HJA
    KRAMERS, H
    CHEMICAL ENGINEERING SCIENCE, 1954, 3 (02) : 55 - 64
  • [3] A NEWLY DEVELOPED LIQUID-LIQUID EXTRACTION COLUMN——The Open Turbine Rotating Disc Contactor(OTRDC)
    朱家文
    章寿华
    周晓葵
    苏元复
    Chinese Journal of Chemical Engineering, 1991, (02) : 208 - 223
  • [4] New predictive correlations for the drop size in a rotating disc contactor liquid-liquid extraction column
    Al-Rahawi, Ayham M. Ismail
    CHEMICAL ENGINEERING & TECHNOLOGY, 2007, 30 (02) : 184 - 192
  • [5] Drop behavior in a pilot plant asymmetric rotating disc extraction column for three various liquid-liquid systems
    Asadollahzadeh, Mehdi
    Torab-Mostaedi, Meisam
    Torkaman, Rezvan
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2018, 138 : 366 - 373
  • [6] LABORATORY LIQUID-LIQUID EXTRACTION COLUMN
    SHORT, JF
    TWIGG, GH
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1951, 43 (12): : 2932 - 2933
  • [7] Holdup profile in multistage stirred-cell liquid-liquid extraction column using population balance model
    Ismail, AS
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2004, 82 (05): : 1037 - 1043
  • [8] Multicomponent and contamination effects on mass transfer in a liquid-liquid extraction rotating disc contactor
    Brodkorb, MJ
    Slater, MJ
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2001, 79 (A3): : 335 - 346
  • [9] Performances of a pulsating column for liquid-liquid extraction
    Tudose, RZ
    Petrescu, S
    Horoba, DL
    Delibas, C
    HUNGARIAN JOURNAL OF INDUSTRIAL CHEMISTRY, 1997, 25 (03): : 203 - 208
  • [10] DYNAMIC SIMULATION OF A LIQUID-LIQUID EXTRACTION COLUMN
    BIERY, JC
    BOYLAN, DR
    INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1963, 2 (01): : 44 - &