Turbidimetric method for quantitative determination of Triton X-100 with silicotungstic acid

被引:5
|
作者
Lagutina, LS [1 ]
Sholts, KF [1 ]
机构
[1] Russian Acad Sci, Bach Inst Biochem, Moscow 117071, Russia
关键词
Calibration Curve; Complex Formation; Quantitative Determination; Complex Nature; Longe Wavelength;
D O I
10.1023/A:1015439912362
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The formation of Triton X-100-silicotungstic acid complex was studied. Quantitative turbidimetric determination of the detergent based on this process was suggested. This method allows us to determine the complex formation at any wavelength in the range from 350 (epsilon(350) = 15 600 cm(-1) M-1) to 600 nm (epsilon(600) = 9090 cm(-1) M-1). The calibration curve for Triton X-100 recorded at 350 nm is linear in the concentration range of 0 to 30 mug/ml. A sigmoid calibration curve was observed at longer wavelengths. A linear fragment of the calibration curve recorded at 600 nm was found at a concentration of Triton X-100 of about 5 mug/ml. The complex nature of calibration curves can be explained by the heterogeneity of the complex dispersion.