Interspinous implant in lumbar spinal stenosis: a prospective cohort

被引:5
|
作者
Bhadra, Arup Kumar [1 ]
Raman, A. S. [1 ]
Tucker, S. [1 ]
Noordeen, H. H. [1 ]
机构
[1] Royal Natl Orthopaed Hosp, Stanmore HA7 4LP, Middx, England
关键词
lumbar spinal stenosis; neurogenic claudication; distractor; efficacy;
D O I
10.1007/s00590-008-0340-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study design Prospective study on clinical outcome of interspinous process distraction with X-STOP in patients with lumbar spinal stenosis. Purpose To determine the safety and efficacy of X-STOP interspinous distractor. Method A total of 45 patients (24 males, 21 females) with lumbar spinal stenosis were treated with X-STOP system. They had preoperative and postoperative (3, 6 and 12 months) assessments using the Back and Sciatica Questionnaire, the Oswestry Disability Index (ODI) and the SF12 Questionnaire. Patient satisfaction was assessed at each visit. Results The average VAS of back and leg pain was 6.7 and 6.8 preoperatively and improved to 2.7 and 2.8 postoperatively. A total of 68% had improvement in their walking distance following the operation. The average preoperative ODI of 42% improved to 16.38% postoperatively (P < 0.0001). A total of 70% of patients had improvement in physical score and 80% in mental score. A total of 82% were very satisfied with the outcome of the operation. Conclusion X-STOP implant is clinically effective with fewer complications and it is a simple procedure.
引用
收藏
页码:489 / 493
页数:5
相关论文
共 50 条
  • [1] Interspinous implant in lumbar spinal stenosis: a prospective cohort
    Arup Kumar Bhadra
    A. S. Raman
    S. Tucker
    H. H. Noordeen
    European Journal of Orthopaedic Surgery & Traumatology, 2008, 18 : 489 - 493
  • [2] Interspinous Spacers for Lumbar Spinal Stenosis
    Long, William D., III
    Whang, Peter G.
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2011, 21 (03) : 208 - 212
  • [3] Surgical Treatment of Lateral Lumbar Spinal Stenosis Using Percutaneous Interspinous Implant
    Mruzek, M.
    Palecek, T.
    Lipina, R.
    CESKA A SLOVENSKA NEUROLOGIE A NEUROCHIRURGIE, 2015, 78 (02) : 167 - 171
  • [4] Endoscopic decompression combined with interspinous process implant fusion for lumbar spinal stenosis
    刘刚
    赵建宁
    Akira Dezawa
    中华创伤杂志(英文版), 2008, (06)
  • [5] Aperius interspinous implant versus open surgical decompression in lumbar spinal stenosis
    Postacchini, Roberto
    Ferrari, Emiliano
    Cinotti, Gianluca
    Menchetti, Pier Paolo Maria
    Postacchini, Franco
    SPINE JOURNAL, 2011, 11 (10): : 933 - 939
  • [6] Endoscopic decompression combined with interspinous process implant fusion for lumbar spinal stenosis
    Liu Gang
    Zhao Jian-ning
    Dezawa, Akira
    CHINESE JOURNAL OF TRAUMATOLOGY, 2008, 11 (06) : 364 - 367
  • [7] Two-Year Results of X-Stop Interspinous Implant for the Treatment of Lumbar Spinal Stenosis A Prospective Study
    Nandakumar, Anjali
    Clark, Natasha A.
    Smith, Francis W.
    Wardlaw, Douglas
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2013, 26 (01): : 1 - 7
  • [8] One-year results of X STOP interspinous implant for the treatment of lumbar spinal stenosis
    Siddiqui, Manal
    Smith, Francis W.
    Wardlaw, Douglas
    SPINE, 2007, 32 (12) : 1345 - 1348
  • [9] Treatment of bisegmental lumbar spinal stenosis: Coflex interspinous implant versus bisegmental posterior lumbar interbody fusion
    Lin, Hongsheng
    Zhang, Guowei
    Wu, Hao
    Liu, Ning
    Zha, Zhengang
    SCIENTIFIC RESEARCH AND ESSAYS, 2011, 6 (02): : 479 - 484
  • [10] Interspinous Implant with Unilateral Laminotomy for Bilateral Decompression of Degenerative Lumbar Spinal Stenosis in Elderly Patients
    Ryu, Sung-Joo
    Kim, In-Soo
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2010, 47 (05) : 338 - 344