Rabbit Intraocular Reactivity to Endotoxin Measured by Slit-Lamp Biomicroscopy and Laser Flare Photometry

被引:12
|
作者
Nussenblatt, Robert B. [2 ]
Calogero, Don [1 ]
Buchen, Shelley Y. [3 ]
Leder, Henry A. [3 ]
Goodkin, Margot [1 ]
Eydelman, Malvina B. [1 ]
机构
[1] US FDA, Ctr Devices & Radiol Hlth, Off Device Evaluat, Div Ophthalm Neurol & Ear Nose & Throat Devices, Silver Spring, MD 20993 USA
[2] NEI, NIH, Bethesda, MD 20892 USA
[3] US FDA, ORISE, Silver Spring, MD 20993 USA
关键词
OCULAR INFLAMMATORY RESPONSE; ANTERIOR SEGMENT; INHIBITION; UVEITIS; ALPHA;
D O I
10.1016/j.ophtha.2012.04.004
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To evaluate the ocular reactivity of the rabbit to an intracameral injection of a dispersive ophthalmic viscosurgical device (OVD) containing various levels of bacterial endotoxin using slit-lamp biomicroscopy and laser flare photometry. Design: Experimental, randomized, masked animal study. Participants: Thirty Dutch-Belted rabbits. Methods: The rabbits were randomized into 6 groups to receive 0.05 ml of a hydroxypropyl methylcellulose-based dispersive OVD to which had been added one of 5 different doses of bacterial endotoxin ranging from 0.02 to 1.4 endotoxin units (EUs) or a vehicle control to both eyes. The eyes were evaluated for anterior segment inflammation at baseline and 3, 6, 9, 24, 48, and 72 hours after injection using slit-lamp biomicroscopy and laser flare photometry. Main Outcome Measures: Corneal clarity and anterior chamber (AC) inflammation. Results: All the corneas remained clear throughout the study. Anterior chamber cells were seen at 6, 9, and 24 hours in 60% to 100% of the eyes intracamerally injected with endotoxin-containing OVD, and the response declined rapidly after 24 hours. A dose-response effect was seen between the concentration of endotoxin and the AC cell response. The aqueous flare response in eyes injected with the 2 highest doses of endotoxin was significantly greater (P<0.05) than that of controls. The amounts of fibrin observed in the AC were random, with no apparent dose-response effect seen. The flare values as obtained by laser flare photometry were consistent with the slit-lamp biomicroscopy flare findings up to grade 3+. However, the increase in laser flare value seemed to level off in eyes with more than 3+ flare. Neither measure of flare correlated with endotoxin level. Conclusions: Among the parameters evaluated in this study, the AC cell response, evaluated by slit-lamp biomicroscopy and graded using a standard grading system, was found to be the most reliable indicator of the amount of endotoxin in the dispersive OVD. The use of laser flare photometry alone does not seem to be useful in detecting an ocular response to endotoxin contamination in OVDs. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. Ophthalmology 2012;119:e19-e23 (C) 2012 by the American Academy of Ophthalmology.
引用
收藏
页码:E19 / E23
页数:5
相关论文
共 50 条
  • [1] Slit-Lamp Biomicroscopy
    Clover, Jameson
    [J]. CORNEA, 2018, 37 : S5 - S6
  • [2] TELEVISION SLIT-LAMP BIOMICROSCOPY
    BRON, AJ
    KAUFMAN, DV
    HARWOOD, D
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1978, 62 (09) : 644 - 650
  • [3] ROLE OF SLIT-LAMP BIOMICROSCOPY IN THE DIAGNOSIS OF CYSTINOSIS
    ABEDI, S
    [J]. ANNALS OF OPHTHALMOLOGY, 1984, 16 (07): : 652 - &
  • [4] DEPTH DISTORTION DURING SLIT-LAMP BIOMICROSCOPY OF THE FUNDUS
    REPKA, MX
    UOZATO, H
    GUYTON, DL
    [J]. OPHTHALMOLOGY, 1986, 93 (09) : 47 - 51
  • [5] Sensitivity of laser flare photometry compared to slit-lamp cell evaluation in monitoring anterior chamber inflammation in uveitis
    Bernasconi O.
    Papadia M.
    Herbort C.P.
    [J]. International Ophthalmology, 2010, 30 (5) : 495 - 500
  • [6] NEW TECHNIQUE FOR COLOR VIDEO SLIT-LAMP BIOMICROSCOPY
    MCCULLEY, JP
    BLUMENKRANZ, MS
    FISHMAN, SS
    [J]. OPHTHALMOLOGY, 1978, 85 (11) : 1193 - 1194
  • [7] AN ADAPTER TO AID IN SLIT-LAMP BIOMICROSCOPY OF THE SUPINE PATIENT
    NURSALL, JF
    [J]. OPHTHALMOLOGY, 1979, 86 (11) : 2048 - 2050
  • [8] SLIT-LAMP FLUOROPHOTOMETRY IN INTRAOCULAR-LENS PATIENTS
    KRAFF, MC
    SANDERS, DR
    PEYMAN, GA
    LIEBERMAN, HL
    TARABISHY, S
    [J]. OPHTHALMOLOGY, 1980, 87 (09) : 877 - 880
  • [9] Comparison of Smartphone Ophthalmoscopy With Slit-Lamp Biomicroscopy for Grading Diabetic Retinopathy
    Russo, Andrea
    Morescalch, Francesco
    Costagliola, Ciro
    Delcassi, Luisa
    Semeraro, Francesco
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (02) : 360 - 364
  • [10] Comparison of Smartphone Ophthalmoscopy with Slit-lamp Biomicroscopy for Undilated Glaucoma Screening
    Russo, Andrea
    Morescalchi, Francesco
    Delcassi, Luisa
    Costagliola, Ciro
    Semeraro, Francesco
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)