Using Enhanced Air Cleaning to Integrate IAQ and Energy Conservation

被引:2
|
作者
Muller, Christopher O. [1 ]
Yu, Henry [1 ]
机构
[1] Purafil Inc, 2654 Weaver Way, Doraville, GA 30340 USA
关键词
air cleaning; energy conservation; indoor air quality; urban air pollution;
D O I
10.1016/j.proeng.2017.10.268
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It is a fact nowadays that urban air pollution in many locations has reached and maintains unacceptable levels. Because of this the use of enhanced air filtration in HVAC design specifications is no longer a luxury but a necessity. The time when code minimum filtration could be used is quickly disappearing and multistage air filtration systems are now required to protect the health, wellbeing, and productivity of the building occupants. Transforming investments in enhanced air filtration into capital equipment and ongoing energy savings can be realized when using the IAQ Procedure (IAQP) of ASHRAE Standard 62.1. With notable trends toward high-rise commercial and residential buildings, employing the IAQP as a design basic for HVAC systems can easily achieve the dual benefits of achieving energy savings by reducing the amount of outdoor ventilation air and achieving significantly improved indoor air quality by direct control of pollutants. The use of the IAQP can also be used in buildings seeking LEED or similar certifications by qualifying for credits under IAQ, energy conservation, design innovation, and other categories. This paper will discuss the IAQP and provide examples of the application of enhanced filtration as a replacement for ventilation air in locations with significant ambient air pollution and the resulting energy savings. (c) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:3042 / 3049
页数:8
相关论文
共 50 条
  • [1] IAQ CONTROL BY AIR CLEANING
    不详
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1987, 29 (07): : 33 - 36
  • [2] PARTICULATE AND ADSORPTION AIR CLEANING FOR CONSERVATION OF ENERGY
    PATE, RG
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1976, 18 (12): : 39 - 39
  • [3] Beyond Ozone: Cleaning Outdoor Air for Improved IAQ
    Muller, Christopher O.
    Jin, Larry
    [J]. 6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1442 - 1450
  • [4] Saving energy by cleaning the air?: Endogenous energy efficiency and energy conservation potential
    Kuang, Yunming
    Tan, Ruipeng
    Zhang, Zihan
    [J]. ENERGY ECONOMICS, 2023, 126
  • [5] Overview of recent researches in IAQ, ventilation, and energy conservation
    Umberto Berardi
    [J]. Building Simulation, 2020, 13 : 977 - 978
  • [6] Overview of recent researches in IAQ, ventilation, and energy conservation
    Berardi, Umberto
    [J]. BUILDING SIMULATION, 2020, 13 (05) : 977 - 978
  • [7] Energy conservation and improved IAQ with existing ventilation standards
    Muller, Christopher O.
    [J]. FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 960 - 967
  • [8] Indoor Air Quality (IAQ) and Energy Efficiency
    Ram, D. Nirmal
    [J]. ASHRAE TRANSACTIONS 2019, VOL 125, PT 1, 2019, 125 : 231 - 237
  • [9] IAQ & Energy Impact of Exhaust Air Transfer Ratio
    Alleva, Samantha
    [J]. ASHRAE JOURNAL, 2017, 59 (11) : 12 - 19
  • [10] Monitoring IAQ and thermal comfort in a conservation area low energy retrofit
    Jimenez-Bescos, Carlos
    Prewett, Robert
    [J]. INTERNATIONAL SCIENTIFIC CONFERENCE ENVIRONMENTAL AND CLIMATE TECHNOLOGIES, CONECT 2018, 2018, 147 : 195 - 201